Train-Induced Vibration Analysis and Isolation Trench Measures in Metro Depot Structures
Source abstract
Abstract
Many cities around the world are developing over-track buildings above metro depots to achieve efficient and economical land use. However, the vibrations generated by frequent train operations have a significant impact on the over-track buildings. Therefore, the analysis and control of vibrations at metro depots are of great importance. This paper focuses on the train-induced vibration propagation law and the application of vibration isolation trench measures of the over-track building in the metro depot. To this end, a typical metro depot is taken as the research object. The train-track model, used for simulating wheel-rail force, and the track-soil-building model, used for predicting structural response, are established, respectively. Then, the vibration response of the over-track building of the metro depot is explored, and the effects of vibration isolation measures of the open trench and infilled trench in the metro depot are studied. The results show that the train-induced vibration excitation of the metro is mainly concentrated in the range of 1 to 80 Hz, and the predominant frequency range of the floor vibration is 25 to 50 Hz. The vibration response of the floor is mainly affected by the stiffness. The larger the floor area, the smaller the vertical natural frequency, and the wider the range between the train vibration excitation areas, the more prone to resonance. In addition, the vibration isolation effect of the open trench is better than that of the infilled trench. The primary factor affecting the vibration isolation performance of open trenches is their depth; the influence of trench position and width on the vibration isolation performance is weaker compared to the depth. In the predominant frequency range of floor vibration, the overall vibration isolation effect of the flexible infilled trenches is better than that of the rigid infilled trenches. The main factor affecting the vibration isolation effect of the infilled trenches is the impedance ratio of the material. Among the six kinds of filling materials selected in this paper, the barrier effect of gravel is the worst, and the barrier effect of foam is the best. Using the measure of a foam infilled trench, Z-vibration levels of floors can be reduced by 8.6–13.9 dB.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Railway Engineering and Dynamics · Structural Engineering and Vibration Analysis · Geotechnical Engineering and Underground Structures
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Architecture and Civil Engineering, Beijing University of Technology, Beijing 100124, China
Funding
National Natural Science Foundation of China
References (39)
Show source-provided references
1. Di, G., Li, H., and Guo, J. (2024). Predicting the Influence of Vibration from Trains in the Throat Area of a Metro Depot on Over-Track Buildings. Appl. Sci., 14.10.3390/app14198598 ↗
2. Measurement of ground and nearby building vibration and noise induced by trains in a metro depot10.1016/j.scitotenv.2015.07.123 ↗
3. Koczwara, K.A., Pachla, F., and Burdzik, R. (2024). Research on Human Exposure to Transport-Induced Vibration in Buildings. Appl. Sci., 14.10.3390/app14199016 ↗
4. Evaluation of subway vibration influence on human exposure comfort of whole-body vibration
5. Numerical simulation of floor vibrations of a metro depot under moving subway trains10.1177/1077546317724322 ↗
6. Analysis on the variation characteristics and formation mechanism of environmental vibration level caused by metro operation
7. Wheel/rail noise reduction through profile modification10.1006/jsvi.1996.0274 ↗
8. Reducing train-induced ground-borne vibration by vehicle design and maintenance10.1080/23248378.2014.994260 ↗
9. Railway Track Vibration and Noise Control for Cigezhuang Depot Property Development of Beijing Daxing International Airport Express First Phase
10. Development and application of high-grade vibration-absorbing fasteners for rail track in internal line of depot with property development
11. Research on technologies of track vibration and noise control for the development of subway depot superstructure
12. Tests for effect of track vibration reduction measures in a depot on vibration and noise reduction of a superstructure
13. Effects of steel spring floating slab on vibration and noise of a rail transit box-girder
14. Simulation study on the effect of damping thickness of viscoelastic damping track bed on tunnel and surface vibration attenuation characteristics
15. Discussion on the application of two foundation isolation measures in buildings receiving excessive vibration from adjacent subway lines
16. Design and seismic response analysis for multiple buildings with large podium using inter-story isolation technology
17. Experimental investigation on the effectiveness of laminated rubber bearings to isolate metro generated vibration10.1016/j.measurement.2017.07.019 ↗
18. Experimental study and application analysis of mechanical performance of 3D isolation/vibration bearings along railway lines
19. Measurement and analysis of vibration isolation effect of building floor near subway
20. Numerical modelling of ground-borne noise and vibration in buildings due to surface rail traffic10.1016/j.jsv.2006.10.019 ↗
21. Simplified Design for Vibration Screening by Open and In-Filled Trenches10.1061/(ASCE)0733-9410(1991)117:1(67) ↗
22. Conte, E., and Dente, G. (1995, January 2–7). Screening of Rayleigh Waves by Open Trenches. Proceedings of the 3rd International Conference on Recent Advances in Geotechnical Earthquake Engineering and Soil Dynamics, St. Louis, MO, USA.
23. Full scale experimental study on vibration scattering using open and in-filled (GeoFoam) wave barriers10.1016/j.soildyn.2010.08.010 ↗
24. Screening effectiveness of open and in-filled wave barriers: A full-scale experimental study10.1016/j.conbuildmat.2015.03.098 ↗
25. Experimental study on vibration-isolation effects of open trench, gravel-filled trench, and piles in a row
26. Vibration isolation of over-track buildings in a metro depot by using trackside wave barriers10.1016/j.jobe.2020.101270 ↗
27. Design and efficiency of a composite vibration isolating screen in soil10.1016/j.soildyn.2012.03.007 ↗
28. Field vibration mitigation by honeycomb WIB for pile foundations of a high-speed train viaduct10.1016/j.soildyn.2003.07.005 ↗
29. Wave Barriers for Reduction of Train-Induced Vibrations in Soils10.1061/(ASCE)1090-0241(2004)130:12(1283) ↗
30. Vibration isolation by a row of piles using a 3-D frequency domain BEM10.1002/(SICI)1097-0207(19991020)46:5<713::AID-NME693>3.0.CO;2-U ↗
31. Three-dimensional analysis of the screening effectiveness of hollow pile barriers for foundation-induced vertical vibration10.1016/j.compgeo.2007.05.010 ↗
32. Three-dimensional analysis of rows of piles as passive barriers for ground vibration isolation10.1016/j.soildyn.2006.02.005 ↗
33. A stress artificial boundary in FEA for near-field wave problem
34. Numerical Study on Ground Surface Vibration Response Under Train Load in Multi Adjacent Tunnels
35. Dynamic response of bridges to moving trains: A study on effects of random track irregularities and bridge skewness10.1016/j.compstruc.2008.12.004 ↗
36. Medina Santiago, A., Orozco Torres, J.A., Hernández Gracidas, C.A., Garduza, S.H., and Franco, J.D. (2023). Diagnosis and Study of Mechanical Vibrations in Cargo Vehicles Using ISO 2631-1:1997. Sensors, 23.10.3390/s23249677 ↗
37. Train-induced field vibration measurements of ground and over-track buildings10.1016/j.scitotenv.2016.09.216 ↗
38. Ground-vibrations induced by trains: Filled trenches mitigation capacity and length influence10.1016/j.conbuildmat.2014.09.083 ↗
39. Non-linear 2-D FE modeling for prediction of screening performance of thin-walled trench barriers in mitigation of train-induced ground vibrations10.1016/j.conbuildmat.2012.12.071 ↗