Optical Behavior of an Enhanced Monofocal Intraocular Lens Compared with a Standard One
Source abstract
Abstract
The aim of this work was to compare an enhanced monofocal (RayOne EMV RAO200E, Rayner) and standard monofocal (RayOne RAO600C Aspheric, Rayner) intraocular lenses (IOLs) for three nominal powers (+10.00 D, +20.00 D and +30.00 D) as a function of the optical aperture diameter (pupil diameter) using a commercial Schlieren phase-shifting deflectometer NIMO TR1504 (Lambda-X, Belgium). From the wavefront maps measured by this instrument, the radial power profiles, the spherical aberration coefficients of the Zernike polynomial expansion (as a function of the optical aperture radius), and the root-mean-square (RMS) of the high-order aberrations (HOAs) were obtained and analyzed by comparing the two models. The results showed that the effective added power that could be obtained with the enhanced model depended directly on the pupil size and the power of the IOL implanted. The higher additions were achieved with the higher nominal IOL powers. The relationship between the pupil diameter, the corneal aberration of the patients and the power profile of these IOLs could have a crucial implication on the far distance and the final effective addition. However, it is important to note that these findings should be clinically validated through the implantation of these models in patients’ lenses.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Ophthalmology and Visual Impairment Studies · Corneal surgery and disorders · Intraocular Surgery and Lenses
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Departamento de Optometría y Visión, Universidad Complutense de Madrid, Av. Arcos del Jalón 118, E-28037 Madrid, Spain
Departamento de Óptica, Universidad Complutense de Madrid, Av. Arcos del Jalón 118, E-28037 Madrid, Spain
Departamento de Óptica y Optometría y Ciencias de la Visión, Universitat de València, Doctor Moliner 50, E-46100 Burjassot, Spain
Funding
Spanish State Research Agency
References (27)
Show source-provided references
1. Changing practice patterns in European cataract surgery as reflected in the European Registry of Quality Outcomes for Cataract and Refractive Surgery 2008 to 201710.1097/j.jcrs.0000000000000457 ↗
2. Multifocal and Extended Depth-of-Focus Intraocular Lenses in 202010.1016/j.ophtha.2020.09.026 ↗
3. Assessment of dysphotopsia in pseudophakic subjects with multifocal intraocular lenses10.1136/bmjophth-2016-000064 ↗
4. Comparison Between an Intraocular Lens with Extended Depth of Focus (Tecnis Symfony ZXR00) and a New Monofocal Intraocular Lens with Enhanced Intermediate Vision (Tecnis Eyhance ICB00)10.1097/APO.0000000000000439 ↗
5. Surface profiles of new-generation IOLs with improved intermediate vision10.1097/j.jcrs.0000000000000215 ↗
6. Special Report: American Academy of Ophthalmology Task Force Consensus Statement for Extended Depth of Focus Intraocular Lenses10.1016/j.ophtha.2016.09.039 ↗
7. Laboratory Investigation of Preclinical Visual-Quality Metrics and Halo-Size in Enhanced Monofocal Intraocular Lenses10.1007/s40123-021-00411-9 ↗
8. (2023, October 01). RayOne Aspheric. Available online: https://rayner.com/en/iol/monofocal/rayone-aspheric/.
9. (2023, October 01). RayOne EMV Hydrophylic EDOF Information Brochure. Available online: https://www.ophtalmoservice.be/sites/default/files/uploads/files/ophtalmo_brochure_2021-2_v4_26.pdf.
10. (2023, October 01). RayOne EMV Surgeon Information Brochure International. Available online: https://rayner.com/wp-content/uploads/2021/12/RayOne-EMV-Surgeon-Information-Brochure-International.pdf.
11. Phase-shifting schlieren: High-resolution quantitative schlieren that uses the phase-shifting technique principle10.1364/AO.42.005046 ↗
12. Alonso, J., Gómez-Pedrero, J.A., and Quiroga, J.A. (2019). Modern Ophthalmic Optics, Cambridge University Press. [1st ed.].10.1017/9781316275474 ↗
13. Leach, R. (2011). Optical Measurement of Surface Topography, Springer.10.1007/978-3-642-12012-1 ↗
14. Deflectometric method for the measurement of user power for ophthalmic lenses10.1364/AO.49.005125 ↗
15. Wade, N.J., and Swanston, M. (2013). Visual Perception: An Introduction, Psychology Press.10.4324/9780203082263 ↗
16. Joannes, L.J.M., Hutsebaut, X., and Dubois, X. (2019). NIMO TR1504 Software User Guide, Version 2.17.3, Lambda-X.
17. Gómez-Pedrero, J.A., Albarrán-Diego, C., García-Montero, M., Garzón, N., and Gonzalez-Fernandez, V. (2023). Influence of Instrumental Factors in the Measurement of Power Profiles of Intraocular Lenses with a Commercial Deflectometer. Appl. Sci., 13.10.1364/opticaopen.23559930.v1 ↗
18. Optical aberrations of the human cornea as a function of age10.1364/JOSAA.17.001697 ↗
19. Contribution of the cornea and internal surfaces to the change of ocular aberrations with age10.1364/JOSAA.19.000137 ↗
20. Optical aberrations and the aging eye10.1097/00004397-200343020-00008 ↗
21. Theoretical comparison of aberration-correcting customized and aspheric intraocular lenses10.3928/1081-597X-20070401-10 ↗
22. Improved functional vision with a modified prolate intraocular lens10.1016/j.jcrs.2003.10.022 ↗
23. Comparison of wavefront aberrations and optical quality of eyes implanted with five different intraocular lenses10.3928/1081-597X-20040701-01 ↗
24. Depth-of-Focus and its Association with the Spherical Aberration Sign. A Ray-Tracing Analysis10.3921/joptom.2010.51 ↗
25. Reliability of power profiles measured on NIMO TR1504 (Lambda-X) and effects of lens decentration for single vision, bifocal and multifocal contact lenses10.1016/j.optom.2015.10.005 ↗
26. Enhanced Depth-of-focus Intraocular Lenses: Latest Wavefront-shaped Optics versus Diffractive Optics10.1097/OPX.0000000000001894 ↗
27. Alarcon, A., Canovas, C., Koopman, B., Pande, M.V., Koch, D.D., and Piers, P. (2023). Optical bench evaluation of the effect of pupil size in new generation monofocal intraocular lenses. BMC Ophthalmol., 23.10.1186/s12886-023-02839-y ↗