journal article·2024-08-28Open access

Analysis of the Forces and Moments in Canine Bodily Movement with Different Clear Aligners’ Extraction Space Designs

Youn-Kyung Choi, Sung-Hun Kim, Hae Ryoun Park, Seong-Sik Kim, Yong-Il Kim

Applied Sciences· Volume 14· Issue 17

Abstract

This study aimed to optimize space closure efficiency by comparing the forces and moments exerted by different designs of clear aligners (CAs) during the movement of maxillary canines into the premolar extraction space. The forces and moments were measured using a multi-axis force/moment transducer on the maxillary right canine. The CAs were fabricated from thermoformed polyethylene terephthalate glycol. The following four edentulous space designs were tested: the edentulous space was left intact (Group 1); the edentulous space was replaced with a premolar pontic (Group 2); the edentulous space was replaced with a half-sized premolar pontic (Group 3); and the edentulous space was replaced with a rectangular column beam (Group 4). The maxillary right canine was moved 0.25 mm distally. All groups experienced buccodistal and intrusive forces; compared with the other groups, Group 1 showed significantly greater intrusive and smaller distal forces, and Group 4 showed significantly greater distal forces. All groups experienced distal tilting, lingual inclination, and mesial rotational moments. These findings suggest that modifying the thickness and extent of the adjacent teeth in the edentulous area of the CA can improve local stiffness, thereby reducing the tipping of the teeth into the edentulous space. This study emphasizes the importance of the CA design in controlling forces and moments for effective orthodontic treatment.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthodontics and Dentofacial Orthopedics · dental development and anomalies · Temporomandibular Joint Disorders

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Orthodontics, Dental Research Institute, School of Dentistry, Pusan National University, Yangsan 50612, Republic of Korea

Department of Oral Pathology, School of Dentistry, Pusan National University, Yangsan 50612, Republic of Korea

Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan 50612, Republic of Korea

Funding

the Dental Research Institute

References (40)

Show source-provided references
1. Twitter analysis of the orthodontic patient experience with braces vs. Invisalign10.2319/062816-508.1 ↗
2. Discomfort associated with Invisalign and traditional brackets: A randomized prospective trial10.2319/091416-687.1 ↗
3. Esthetic orthodontic treatment using the Invisalign appliance for moderate to complex malocclusions10.1002/j.0022-0337.2008.72.8.tb04570.x ↗
4. Efficacy of clear aligners in controlling orthodontic tooth movement: A systematic review10.2319/061614-436.1 ↗
5. Three-dimensional diagnosis and orthodontic treatment of complex malocclusions with the Invisalign appliance10.1053/sodo.2001.25414 ↗
6. Has Invisalign improved? A prospective follow-up study on the efficacy of tooth movement with Invisalign10.1016/j.ajodo.2019.12.015 ↗
7. Efficiency of upper arch expansion with the Invisalign system10.2319/022719-151.1 ↗
8. How well does Invisalign work? A prospective clinical study evaluating the efficacy of tooth movement with Invisalign10.1016/j.ajodo.2007.05.018 ↗
9. Jiang, T., Wu, R.Y., Wang, J.K., Wang, H.H., and Tang, G.H. (2020). Clear aligners for maxillary anterior en masse retraction: A 3D finite element study. Sci. Rep., 10.10.1038/s41598-020-67273-2 ↗
10. Integrated three-dimensional digital assessment of accuracy of anterior tooth movement using clear aligners10.4041/kjod.2015.45.6.275 ↗
11. Outcome assessment of Invisalign and traditional orthodontic treatment compared with the American Board of Orthodontics objective grading system10.1016/j.ajodo.2005.06.002 ↗
12. Predictability of orthodontic movement with orthodontic aligners: A retrospective study10.1186/s40510-017-0190-0 ↗
13. Improving the predictability of clear aligners10.1053/j.sodo.2016.10.005 ↗
14. Forces and moments generated by removable thermoplastic aligners: Incisor torque, premolar derotation, and molar distalization10.1016/j.ajodo.2014.03.015 ↗
15. Activation time and material stiffness of sequential removable orthodontic appliances. Part 3: Premolar extraction patients10.1016/j.ajodo.2006.06.025 ↗
16. Advances in orthodontic clear aligner materials
17. Comparison of achieved and predicted tooth movement of maxillary first molars and central incisors: First premolar extraction treatment with Invisalign10.2319/090418-646.1 ↗
18. Torque movement of the upper anterior teeth using a clear aligner in cases of extraction: A finite element study10.1186/s40510-022-00421-8 ↗
19. Forces and moments generated by 3D direct printed clear aligners of varying labial and lingual thicknesses during lingual movement of maxillary central incisor: An in vitro study10.1186/s40510-023-00475-2 ↗
20. Numerical simulation of canine retraction with T-loop spring based on the updated moment-to-force ratio10.1093/ejo/cjq164 ↗
21. Initial force systems during bodily tooth movement with plastic aligners and composite attachments: A three-dimensional finite element analysis10.2319/050714-330.1 ↗
22. A method for evaluation of the effects of attachments in aligner-type orthodontic appliance: Three-dimensional finite element analysis10.1016/j.odw.2017.09.001 ↗
23. Effect of attachment type on distal bodily movement of the maxillary canine in aligner orthodontics: A finite element study10.2319/120121-879.1 ↗
24. Initial forces acting on the maxillary teeth with aligner activation of canine distalization on the basis of different initial canine tips in vitro10.1016/j.ajodo.2022.10.026 ↗
25. Proffit, W.R., Fields, H., Msd, D.M., Larson, B., and Sarver, D. (2018). Contemporary Orthodontics, Mosby Elsevier. [6th ed.].
26. Biomechanics of clear aligners: Hidden truths & first principles
27. Computer aided finite element model for biomechanical analysis of orthodontic aligners10.1007/s00784-022-04692-7 ↗
28. Effect of material composition and thickness of orthodontic aligners on the transmission and distribution of forces: An in vitro study10.1007/s00784-024-05662-x ↗
29. Influence of thermoplastic appliance thickness on the magnitude of force delivered to a maxillary central incisor during tipping10.1016/j.ajodo.2008.12.015 ↗
30. Micro-computed tomography evaluation of general trends in aligner thickness and gap width after thermoforming procedures involving six commercial clear aligners: An in vitro study10.4041/kjod.2021.51.2.135 ↗
31. Elshazly, T.M., Salvatori, D., Elattar, H., Bourauel, C., and Keilig, L. (2023). Effect of trimming line design and edge extension of orthodontic aligners on force transmission: A 3D finite element study. J. Mech. Behav. Biomed. Mater., 140.10.1016/j.jmbbm.2023.105741 ↗
32. The effect of gingival margin design on the retention of thermoformed aligners
33. Effect of trimming line design and edge extension of orthodontic aligners on force transmission: An in vitro study10.1016/j.jdent.2022.104276 ↗
34. Staging orthodontic aligners for complex orthodontic tooth movement10.5152/TurkJOrthod.2021.20116 ↗
35. Comparison between the designed and achieved mesiodistal angulation of maxillary canines and posterior teeth and influencing factors: First premolar extraction treatment with clear aligners10.1016/j.ajodo.2022.05.006 ↗
36. Preparation and characterization of thermoplastic materials for invisible orthodontics10.4012/dmj.2011-120 ↗
37. A new type of clear orthodontic retainer incorporating multi-layer hybrid materials10.4041/kjod.2015.45.5.268 ↗
38. Effect of thermoplastic appliance thickness on initial stress distribution in periodontal ligament10.1177/1687814015578362 ↗
39. The effect of thickness and deflection of orthodontic thermoplastic materials on its mechanical properties10.4041/kjod.2010.40.1.16 ↗
40. The effect of enhanced structure in the posterior segment of clear aligners during anterior retraction: A three-dimensional finite element and experimental model analysis10.1186/s40510-023-00502-2 ↗