Study on the Smoke Control Performance of Air Curtains in Emergency Stairwells of Multi-Unit Residential Buildings
Source abstract
Abstract
Recently, in high-rise buildings, pressurization systems have been installed in emergency stairwells to prevent the ingress of smoke. However, in older buildings, these stairwells often lack pressurization systems, while in buildings with fewer stories, such systems are not typically installed. This study conducts simulations and a hot smoke test to evaluate the performance of air curtains in blocking smoke and toxic gases in outdoor emergency stairwells where additional pressurization equipment cannot be installed. The simulation results showed that air curtains installed perpendicular to the floor were useful at preventing smoke ingress, and higher wind speeds increased their effectiveness. It is believed that air curtains can partially reduce smoke ingress in stairwells of older buildings or low-rise structures without pressurization systems, thereby ensuring fire safety.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Education, Safety, and Science Studies · Fire dynamics and safety research · Energy and Environmental Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Korea Fire & Explosion Solutions Corporation, 22 Misagangbyeonseo-ro, Hanam-si 12918, Republic of Korea
Department of Fire and Disaster Prevention Engineering, Halla University, 28 Halladae-gil, Heungeop-myeon, Wonju-si 26404, Republic of Korea
References (13)
Show source-provided references
1. (2023). 2022 Population and Housing Census.
2. Study on evacuation safety in high-rise fires—Focusing on escape-type evacuation systems
3. Study on the demographic characteristics of fatalities in multi-unit residential fires 2
4. High-rise building fire safety using mechanical ventilation and stairwell pressurization: A review10.1016/j.jobe.2022.104224 ↗
5. Simulations of smoke flow fields in a wind tunnel under the effect of an air curtain for smoke confinement10.1007/s10694-016-0598-y ↗
6. Air curtain as a barrier for smoke in case of fire: Numerical modelling
7. CFD modelling of aerodynamic sealing by vertical and horizontal air curtains10.1016/j.enbuild.2012.06.007 ↗
8. An experiment and simulation of smoke confinement and exhaust efficiency utilizing a modified opposite double-jet air curtain10.1016/j.ssci.2012.12.002 ↗
9. The effect of vertical and horizontal air curtain on smoke and heat control in the multi-storey building10.1016/j.jobe.2021.102347 ↗
10. Air curtain to control smoke and fire spread in a ventilated multi-floor building10.1016/j.ijthermalsci.2020.106612 ↗
11. Zhou, Z., Lu, Y., and Cui, Y. (2021). Study on the Effect of Jet Direction of Compound Air Curtain on Smoke Control. Energies, 14.10.3390/en14216983 ↗
12. Evaluation of air curtain and emergency exhaust system for smoke confinement of an enclosure10.1016/j.jobe.2020.101650 ↗
13. Yan, X., Yang, H., Mo, H., Xie, Y., Jin, Z., and Zhou, Y. (2023). Numerical Simulation on the Smoke Prevention Performance of Air Curtains in an Island-Type Subway Station. Fire, 6.10.3390/fire6050177 ↗