Show source-provided references
1. World Health Organization (2020). World Cancer Report: Cancer Research for Cancer Development.
2. Global Cancer Statistics 2020: GLOBOCAN Estimates of Incidence and Mortality Worldwide for 36 Cancers in 185 Countries
10.3322/caac.21660 ↗4. Verstockt, J., Verspeek, S., Thiessen, F., Tjalma, W.A., Brochez, L., and Steenackers, G. (2022). Skin Cancer Detection Using Infrared Thermography: Measurement Setup, Procedure and Equipment. Sensors, 22.
10.3390/s22093327 ↗5. Skin cancer screening: Recommendations for data-driven screening guidelines and a review of the US Preventive Services Task Force controversy
10.2217/mmt-2016-0022 ↗7. Impact of skin cancer screening and secondary prevention campaigns on skin cancer incidence and mortality: A systematic review
10.1016/j.jaad.2016.07.045 ↗9. Rey-Barroso, L., Peña-Gutiérrez, S., Yáñez, C., Burgos-Fernández, F.J., Vilaseca, M., and Royo, S. (2021). Optical Technologies for the Improvement of Skin Cancer Diagnosis: A Review. Sensors, 21.
10.3390/s21010252 ↗11. Qi, H., and Diakides, N. (2007). Infrared Imaging in Medicine, University of Tennessee. Technical Report.
13. Buzug, T.M., Schumann, S., Pfaffmann, L., Reinhold, U., and Ruhlmann, J. (September, January 30). Functional infrared imaging for skin-cancer screening. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology—Proceedings, New York, NY, USA.
18. Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
10.1117/1.2335429 ↗21. Stable tissue-simulating phantoms with various water and lipid contents for diffuse optical spectroscopy
10.1364/BOE.9.005792 ↗22. Review of tissue simulating phantoms with controllable optical, mechanical and structural properties for use in optical coherence tomography
10.1364/BOE.3.001381 ↗23. Nordstrom, R.J. (2011, January 26). Phantoms as standards in optical measurements. Proceedings of the Optical Diagnostics and Sensing XI: Toward Point-of-Care Diagnostics; and Design and Performance Validation of Phantoms Used in Conjunction with Optical Measurement of Tissue III, SPIE, San Francisco, CA, USA.
10.1117/12.876374 ↗25. In vivo measurement of the human epidermal thickness in different localizations by multiphoton laser tomography
29. Basic physiology of the skin
30. Effects of Heat and Moisture Transport in Fabrics and Garments Determined with a Vertical Plate Sweating Skin Model
10.1177/004051750007000612 ↗32. Dynamic Moisture Vapor Transfer Through Textiles: Part III: Effect of Film Characteristics on Microclimate Moisture and Temperature Changes
10.1177/004051759906900306 ↗33. Experimental validation of a tractable numerical model for focused ultrasound heating in flow-through tissue phantoms
10.1121/1.1787124 ↗35. Çetingül, M.P., and Herman, C. (2010). Volume 2: Biomedical and Biotechnology Engineering, ASMEDC.
37. Near-infrared laser irradiation of a multilayer agar-gel tissue phantom to induce thermal effect of traditional moxibustion
10.1142/S1793545818500335 ↗38. Hou, S. (2018). Photo-Thermally Enhanced Temperature Gradient Gel Electrophoresis for DNA Separation. [Ph.D. Thesis, Northeastern University].
41. Strąkowska, M., Strzelecki, M., and Kaszuba, A. (2014, January 22–24). Novel methodology of medical screening using IR thermography. Proceedings of the 2014 Signal Processing: Algorithms, Architectures, Arrangements, and Applications (SPA), Poznan, Poland.
42. Buzug, T., Schumann, S., Pfaffmann, L., Reinhold, U., and Ruhlmann, J. (2006, January 8–11). Skin-Tumour Classification with Functional Infrared Imaging. Proceedings of the 8th IASTED International Conference on Signal and Image Processing, SIP 2006, Atlanta, GA, USA.
44. Quantitative Evaluation of Skin Lesions Using Transient Thermal Imaging
46. Detection theory for accurate and non-invasive skin cancer diagnosis using dynamic thermal imaging
10.1364/BOE.8.002301 ↗48. Distinguishing melanocytic nevi from melanomas using static and dynamic infrared thermal imaging
10.1111/jdv.15611 ↗51. Hamblin, M.R., Avci, P., and Gupta, G.K. (2016). Imaging in Dermatology, Academic Press.
52. Infantile hemangioma status by dynamic infrared thermography: A preliminary study
10.1111/ijd.13298 ↗53. (2023, May 28). Cryo 6 Brochure—Information about the Zimmer Skin Cooling Chiller. Available online: https://zimmerusa.com/products/cryo-therapy/cryo-6/cryo-6-brochure/.
54. Phillips, G.O., and Williams, P.A. (2009). Handbook of Hydrocolloids, Woodhead Publishing. [2nd ed.]. Woodhead Publishing Series in Food Science, Technology and Nutrition.
57. Ullman, D.G. (2010). The Mechanical Design Process, McGraw-Hill Higher Education. [4th ed.]. McGraw-Hill Series in Mechanical Engineering.
58. Tague, N.R. (2005). The Quality Toolbox, ASQ Quality Press. [2nd ed.].
59. Breast tumor localization using skin surface temperatures from a 2D anatomic model without knowledge of the thermophysical properties
10.1016/j.cmpb.2019.02.004 ↗61. Feasibility test of Dynamic Cooling for detection of small tumors in IR thermographic breast imaging
10.1515/cdbme-2019-0100 ↗