Quantification of the Effective Detectable Period for Concrete Voids of CLP by Lock-In Thermography
Source abstract
Abstract
This study is to inspect the voids between the concrete containment building and the containment liner plate (CLP) in the light-water reactor type nuclear power plant with lock-in thermography (LIT) inspection technology. For that, a finite element method (FEM) model containing concrete voids was created, and the thermal distribution change of the CLP surface was simulated through numerical analysis simulation of various LIT inspection conditions and converted with real-time thermography data. For the simulated temperature distribution image and the amplitude and phase images calculated by the four-point method, the signal-to-noise ratio (SNR) is analyzed based on the sound area and void areas. As a result, the difference in SNR according to the size of voids was remarkable, and the effective detectable period (EDP), which was common to each inspection condition, was derived. Furthermore, a CLP concrete mockup identical to the model shape is produced, and the thermal image of the EDP is analyzed through the experiment with the same analysis technique, and the results are compared. Although there are some differences between the numerical analysis conditions and the experimental environments, the deduction and utilization of EDP through FEM simulation are considered useful approaches to applying LIT to inspect concrete voids on the back of the CLP.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Thermography and Photoacoustic Techniques · Fire effects on concrete materials · Ultrasonics and Acoustic Wave Propagation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
enesG, 8, Techno 10-ro, Yuseong-gu, Daejeon 34026, Republic of Korea
Eco-Sustainable Energy Research Institute, Kongju National University, 1223-24 Cheonan-daero, Seobuk-gu, Cheonan-si 31080, Republic of Korea
Division of Mechanical & Automotive Engineering, Kongju National University, 1223-24 Cheonan-daero, Seobuk-gu, Cheonan-si 31080, Republic of Korea
Funding
Korea Ministry of SMEs and Startups in 2023
References (27)
Show source-provided references
1. Nondestructive Testing Overview
2. Application of Non-destructive Testing (NDT) Techniques on Reinforced Concrete Structure: A Review10.22214/ijraset.2023.47231 ↗
3. Fourier-transform vibrothermography with frequency sweep excitation utilizing local defect resonances10.1016/j.ndteint.2016.11.012 ↗
4. Tran, Q.H., Han, D., Kang, C., Haldar, A., and Huh, J. (2017). Effects of Ambient Temperature and Relative Humidity on Subsurface Defect Detection in Concrete Structures by Active Thermal Imaging. Sensors, 17.10.3390/s17081718 ↗
5. Ciampa, F., Mahmoodi, P., Pinto, F., and Meo, M. (2018). Recent Advances in Active Infrared Thermography for Non-Destructive Testing of Aerospace Components. Sensors, 18.10.3390/s18020609 ↗
6. Huh, J., Mac, V.H., Tran, Q.H., Lee, K.-Y., Lee, J.-I., and Kang, C. (2018). Detectability of Delamination in Concrete Structure Using Active Infrared Thermography in Terms of Signal-to-Noise Ratio. Appl. Sci., 8.10.3390/app8101986 ↗
7. An Overview of Corrosion Defect Characterization using Active Infrared Thermography10.1016/j.infrared.2018.12.006 ↗
8. Laureti, S., Rizwan, M.K., Malekmohammadi, H., Burrascano, P., Natali, M., Torre, L., Rallini, M., Puri, I., Hutchins, D., and Ricci, M. (2019). Delamination Detection in Polymeric Ablative Materials using Pulse-Compression Thermography and Air-Coupled Ultrasound. Sensors, 19.10.3390/s19092198 ↗
9. Microstructural Assessment of 316L Stainless Steel Using Infrared Thermography Based Measurement of Energy Dissipation Arising from Cyclic Loading10.1016/j.mechmat.2020.103455 ↗
10. Moskovchenko, A., Vavilov, V., Švantner, M., Muzika, L., and Houdková, Š. (2020). Active IR Thermography Evaluation of Coating Thickness by Determining Apparent Thermal Effusivity. Materials, 13.10.3390/ma13184057 ↗
11. Milovanović, B., Gaši, M., and Gumbarević, S. (2020). Principal Component Thermography for Defect Detection in Concrete. Sensors, 20.10.3390/s20143891 ↗
12. Garrido, I., Solla, M., Lagüela, S., and Fernández, N. (2020). IRT and GPR Techniques for Moisture Detection and Characterisation in Buildings. Sensors, 20.10.3390/s20226421 ↗
13. Experimental and numerical investigation on detection fatigue crack in metallic plate by vibro-thermography10.1016/j.infrared.2022.104347 ↗
14. Nuclear Safety and Security Committee (2023, May 07). Result of Inspection of the Root Cause of Voids in the Containment Building of Hanbit Units 3 and 4, Available online: https://www.nssc.go.kr/ajaxfile/FR_SVC/FileDown.do?GBN=X01&BOARD_SEQ=5&SITE_NO=2&BBS_SEQ=46152&FILE_SEQ=1.
15. Nuclear Safety and Security Committee (2023, May 07). Status of Special Inspection of Nuclear Power Plant Structures and Future Plans, Available online: https://www.nssc.go.kr/ajaxfile/FR_SVC/FileDown.do?GBN=X01&BOARD_SEQ=5&SITE_NO=2&BBS_SEQ=45575&FILE_SEQ=22884.
16. Maldague, X. (2001). Theory and Practice of Infrared Technology for Nondestructive Testing, Wiley-Interscience.
17. Evaluation of Coating Thickness by Thermal Wave Imaging: A Comparative Study of Pulsed and Lock-in Infrared Thermography–Part I: Simulation10.1016/j.infrared.2017.04.016 ↗
18. Thermographic Inspection of CLP Defects on the Subsurface Based on Binary Image10.1007/s12541-021-00616-9 ↗
19. Evaluation of Coating Thickness by Thermal Wave Imaging: A Comparative Study of Pulsed and Lock-in Infrared thermography–Part II: Experimental Investigation10.1016/j.infrared.2018.05.001 ↗
20. Maldague, X.P.V., and Moore, P.O. (2001). Nondestructive Testing Handbook Series III, American Society for Nondestructive Testing. [3rd ed.].
21. Recent Advances in the use of Infrared Thermography10.1088/0957-0233/15/9/R01 ↗
22. Spatial and temporal modulation of heat source using light modulator for advanced thermography
23. Numerical Simulation of Phase Images and Depth Reconstruction in Pulsed Phase Thermography10.1088/0957-0233/26/11/115602 ↗
24. Evaluation of Image Quality using ATS-539 Phantom and SNR in the Ultrasonographic Equipment10.5392/JKCA.2013.13.08.284 ↗
25. Fundamentals of Heat Exchangers
26. Optimization Method for Evaluating Essential Factors of Plate Backside Thinning Defects using Lock-in Thermography10.7779/JKSNT.2020.40.6.452 ↗
27. Ciorau, P. (2011). Comparison Between −6 DB and −12 DB Amplitude Drop Techniques for Length Sizing. E-J. Nondestruct. Test., 16, Available online: https://www.ndt.net/?id=11175.