Intracranial pressure (ICP) is an important measurement in the treatment of Traumatic Brain Injury (TBI). Currently, ICP can only be measured invasively, which exposes patients to operative risk and can only be performed by neurosurgeons. Hence, there is a significant need for a non-invasive ICP technology. This paper describes the evaluation of a novel non-invasive intracranial pressure (nICP) monitor which uses the Photoplethysmogram (PPG) to measure the ICP. The monitor was evaluated in an in vitro model that simulated cerebral haemodynamics and allowed the controlled manipulation of ICP. A number of features from the PPG were extracted and utilised in a machine learning model to estimate ICP. Three separate measurements in which the ICP was varied were performed, and the estimated ICP (nICP) was compared with reference (invasive) ICP measurements. The ICP estimated by the nICP monitor was highly correlated with reference ICP measurements (Pearson’s correlation coefficient between 0.95 and 0.98). The nICP monitor also showed a low Root Mean Square Error from the reference ICP measure (3.12, 1.48, and 1.45 mmHg). Analysis of agreement by Bland and Altman also revealed good agreement between the two techniques. The optical nICP monitor was able to estimate the ICP non-invasively from an in vitro model simulating intracranial hypertension. The non-invasive ICP monitor showed very promising results which can set the base for further investigations. This work contributes significantly to the quest for non-invasive ICP monitoring in Traumatic Brain Injury (TBI), and paves the way for further research in this field.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Non-Invasive Vital Sign Monitoring · Traumatic Brain Injury and Neurovascular Disturbances · Hemodynamic Monitoring and Therapy

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Research Centre for Biomedical Engineering, City, University of London, London EC1V 0HB, UK

The Department of Neurosurgery, Royal London Hospital (Barts Health NHS Trust), London E1 1FR, UK

Funding

National Institute for Health Research (NIHR) [Invention for Innovation (i4i) Product Development

References (35)

Show source-provided references
1. Global, regional, and national burden of traumatic brain injury and spinal cord injury, 1990–2016: A systematic analysis for the Global Burden of Disease Study 201610.1016/S1474-4422(18)30415-0 ↗
2. Monro-Kellie 2.0: The dynamic vascular and venous pathophysiological components of intracranial pressure10.1177/0271678X16648711 ↗
3. Monitoring intracranial pressure in traumatic brain injury10.1213/01.ane.0000297296.52006.8e ↗
4. Monitoring and interpretation of intracranial pressure10.1136/jnnp.2003.033126 ↗
5. Raised intracranial pressure10.1136/jnnp.73.suppl_1.i23 ↗
6. Le Roux, P. (2016). Intracranial pressure monitoring and management. Translational Research in Traumatic Brain In-Jury, Taylor and Francis Group.
7. Intraparenchymal vs. extracranial ventricular drain intracranial pressure monitors in trau-matic brain injury: Less is more?10.1016/j.jamcollsurg.2012.03.004 ↗
8. Complications of invasive intracranial pressure mon-itoring devices in neurocritical care10.3171/2017.8.FOCUS17450 ↗
9. Roldán, M., and Kyriacou, P. (2021). Near-Infrared Spectroscopy (NIRS) in Traumatic Brain Injury (TBI). Sensors, 21.10.3390/s21051586 ↗
10. Non-Invasive Techniques for Multimodal Monitoring in Traumatic Brain Injury: Systematic Review and Meta-Analysis10.1089/neu.2020.7266 ↗
11. Invasive and noninvasive means of measuring intracranial pressure: A review10.1088/1361-6579/aa7256 ↗
12. Noninvasive monitoring intracranial pressure—A review of available modalities10.4103/sni.sni_403_16 ↗
13. Age-related changes in spontaneous oscillations assessed by wavelet transform of cerebral oxygena-tion and arterial blood pressure signals10.1038/jcbfm.2013.4 ↗
14. Photoplethysmography and its application in clinical physiological measurement10.1088/0967-3334/28/3/R01 ↗
15. Kyriacou, P.A., and Allen, J. (2021). Photoplethysmography Technology, Signal Analysis and Applications, Elsevier.
16. Optimizing probe design for an implantable perfusion and oxygenation sensor10.1364/BOE.2.002096 ↗
17. Phantom model of physiologic intracranial pressure and cerebrospi-nal fluid dynamics10.1109/TBME.2012.2187448 ↗
18. Near infrared brain and muscle oximetry: From the discovery to current applica-tions10.1255/jnirs.973 ↗
19. Roldan, M., Chatterjee, S., and Kyriacou, P.A. (2021, January 1–5). Light-Tissue Interaction Modelling of Human Brain towards the Optical Sensing of Traumatic Brain Injury. Proceedings of the 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), Virtual.
20. Design and development of a modular, multichannel photople-thysmography system10.1109/TIM.2018.2810643 ↗
21. Enhanced in-vitro model of the CSF dynamics10.1186/s12987-019-0131-z ↗
22. Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry10.1117/1.2335429 ↗
23. Geometrically complex 3D-printed phantoms for diffuse optical imaging10.1364/BOE.8.001754 ↗
24. Fabrication and characterization of silicone-based tis-sue phantoms with tunable optical properties in the visible and near infrared domain10.1117/12.764969 ↗
25. Optical phantoms with adjustable subdiffusive scattering parameters10.1117/1.JBO.20.10.105008 ↗
26. Optofluidic phantom mimicking optical properties of porcine livers10.1364/BOE.2.001877 ↗
27. Rapid prototyping of biomimetic vascular phantoms for hyperspectral reflectance imaging10.1117/1.JBO.20.12.121312 ↗
28. Assessment of a noninvasive optical photoplethysmography imaging device with dynamic tis-sue phantom models10.1117/1.JBO.22.9.096003 ↗
29. Phantom with pulsatile arteries to investigate the influence of blood vessel depth on pulse oximeter signal strength10.3390/s120100895 ↗
30. Accuracy of intracranial pressure monitor-ing: Systematic review and meta-analysis10.1186/s13054-015-1137-9 ↗
31. Advances in intracranial pressure monitoring and its significance in managing traumatic brain injury10.3390/ijms161226146 ↗
32. Hughes, J.A., Jackson, E.C., and Daley, M. (2022, November 29). Modelling Intracranial Pressure with Noninvasive Physiological Measures. Available online: https://physionet.org/mimic2/.
33. Photoplethysmography temporal marker-based machine learning classifier for anesthesia drug detection10.1007/s11517-022-02658-1 ↗
34. Innovative multi-site photoplethysmography measurement and analysis demonstrating increased arterial stiffness in paediatric heart transplant recipients10.1088/1361-6579/aac76a ↗
35. Comparison of different modulations of photoplethysmography in extracting respiratory rate: From a physiological perspective10.1088/1361-6579/abaaf0 ↗