journal article·2022-11-28Open access

Fluence Beam Monitor for High-Intensity Particle Beams Based on a Multi-Gap Ionization Chamber and a Method for Ion Recombination Correction

Simona Giordanengo, Leslie Fanola Guarachi, Saverio Braccini, Giuseppe A. P. Cirrone, Marco Donetti, Federico Fausti, Felix Mas Milian, Francesco Romano, Anna Vignati, Vincenzo Monaco, Roberto Cirio, Roberto Sacchi

Applied Sciences· Volume 12· Issue 23

Abstract

This work presents the tests of a multi-gap detector (MGD), composed of three parallel-plate ionization chambers (ICs) with different gap widths, assembled to prove the capability of correcting for charge volume recombination which is expected to occur when high fluence rates are delivered. Such beam conditions occur with a compact accelerator for charged particle therapy developed to reduce the costs, to accomplish faster treatments and to exploit different beam delivery techniques and dose rates as needed, for example, for range modulation and FLASH irradiations, respectively. The MGD was tested with carbon ions at the Centro Nazionale di Adroterapia Oncologica (CNAO Pavia, Italy), and with protons in two different beam lines: at Bern University Hospital with continuous beams and at the Laboratori Nazionale del Sud (Catania, Italy) of the Italian National Center of Nuclear Physics (INFN) with pulsed beams. For each accelerator, we took measurements with different beam intensities (up to the maximum rate of ionization achievable) and changed the detector bias voltage (V) in order to study the charge collection efficiency. Charge recombination models were used to evaluate the expected collected charge and to measure the linearity of the rate of ionization with the beam fluence rate. A phenomenological approach was used to determine the collection efficiency (f1) of the chamber with thinnest gap from the relative efficiencies, f1/f2 and f1/f3, exploiting the condition that, for each measurement, the three chambers were exposed to the same rate of ionization. Results prove that two calibration curves can be determined and used to correct the online measurements for the charge losses in the ICs for recombination.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Radiation Therapy and Dosimetry · Advanced Radiotherapy Techniques · Radiation Detection and Scintillator Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Istituto Nazionale di Fisica Nucleare, Division of Torino, 10125 Torino, Italy

Physics Department, Università di Torino, 10125 Torino, Italy

Albert Einstein Center for Fundamental Physics (AEC), Laboratory for High Energy Physics (LHEP), University of Bern, 3012 Bern, Switzerland

Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, 95123 Catania, Italy

Centro Nazionale di Adroterapia Oncologica (CNAO), 27100 Pavia, Italy

Departamento de Ciencias Exactas, Universidade Estadual de Santa Cruz, Ilhéus 45662-900, Brazil

Istituto Nazionale di Fisica Nucleare, Division of Catania, 95123 Catania, Italy

Funding

INFN CSN5

References (30)

Show source-provided references
1. Evolution of technology to optimize the delivery of proton therapy: The third generation10.1016/j.semradonc.2012.11.006 ↗
2. Future Developments in Charged Particle Therapy: Improving Beam Delivery for Efficiency and Efficacy10.3389/fonc.2021.780025 ↗
3. Roadmap: Proton therapy physics and biology10.1088/1361-6560/abcd16 ↗
4. Ultra-high dose rate dosimetry: Challenges and opportunities for FLASH radiation therapy10.1002/mp.15649 ↗
5. The current status of preclinical proton FLASH radiation and future directions10.1002/mp.15276 ↗
6. Pardo-Montero, J., Paz-Martín, J., Brualla-Gónzalez, L., and Gómez, F. (2021). Online Recombination Correction in Dosimetry with Arrays of Ionization Chambers: Application to FFF and UHDR Radiotherapy. Appl. Sci., 11.10.3390/app112110083 ↗
7. Characterization of a high-resolution 2D transmission ion chamber for independent validation of proton pencil beam scanning of conventional and FLASH dose delivery10.1002/mp.14882 ↗
8. Development of an ultra-thin parallel plate ionization chamber for dosimetry in FLASH radiotherapy10.1002/mp.15668 ↗
9. Design and characterization of the beam monitor detectors of the Italian National Center of Oncological Hadron-therapy (CNAO)10.1016/j.nima.2012.10.004 ↗
10. Online beam monitoring in the treatment of ocular pathologies at the INFN Laboratori Nazionali del Sud-Catania10.1016/j.ejmp.2010.10.004 ↗
11. Segmented ionization chambers for beam monitoring in hadrontherapy10.1142/S021773231540026X ↗
12. Design and characterization of a 64channels ASIC front-end electronics for high-flux particle beam detectors10.1016/j.nima.2017.04.025 ↗
13. A simple method to increase the current range of the TERA chip in charged particle therapy applications10.1016/j.nima.2015.07.013 ↗
14. The National Centre for Oncological Hadrontherapy (CNAO): Status and perspectives10.1016/j.ejmp.2015.03.001 ↗
15. Dosimetric commissioning and quality assurance of scanned ion beams at the Italian National Center for Oncological Hadrontherapy10.1118/1.4928397 ↗
16. The new bern PET cyclotron, its research beam line, and the development of an innovative beam monitor detector10.1063/1.4802308 ↗
17. Low current performance of the Bern medical cyclotron down to the pA range10.1088/0957-0233/26/9/094006 ↗
18. A facility for radiation hardness studies based on a medical cyclotron10.1088/1748-0221/17/04/P04021 ↗
19. A detector based on silica fibers for ion beam monitoring in a wide current range10.1088/1748-0221/11/03/P03027 ↗
20. Clinical and Research Activities at the CATANA Facility of INFN-LNS: From the Conventional Hadrontherapy to the Laser-Driven Approach10.3389/fonc.2017.00223 ↗
21. The ELIMED transport and dosimetry beamline for laser-driven ion beams10.1016/j.nima.2016.01.064 ↗
22. Scuderi, V., Amato, A., Amico, A.G., Borghesi, M., Cirrone, G.A.P., Cuttone, G., Fajstavr, A., Giuffrida, L., Grepl, F., and Korn, G. (2018). Diagnostics and Dosimetry Solutions for Multidisciplinary Applications at the ELIMAIA Beamline. Appl. Sci., 8.10.3390/app8091415 ↗
23. Andreo, P., Burns, D.T., Hohlfeld, K., Huq, M.S., Kanai, T., Laitano, F., Smyth, V.G., and Vynckier, S. (2000). Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water, IAEA.
24. Saturation Characteristics of Parallel-Plate Ionization Chambers10.1088/0031-9155/9/2/302 ↗
25. Roos, M., and Derikum, K. (2000). The Recombination Correction and the Dependence of the Response of Plane Parallel Chambers on the Polarizing Voltage in Pulsed Electron and Photon Beams, Physikalisch-Technische Bundesanstalt. Review of Data and Methods Recommended in the International Code of Practice for Dosimetry, IAEA TECDOC 1173.
26. Initial recombination of ions10.1103/PhysRev.54.554 ↗
27. Initial recombination in a parallel-plate ionization chamber exposed to heavy ions10.1088/0031-9155/43/12/012 ↗
28. AAPM’s TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams10.1118/1.598691 ↗
29. The saturation curve at high ionization intensity10.1088/0508-3443/3/7/305 ↗
30. Ionization Measurements at Very High Intensities—Part I10.1259/0007-1285-23-274-601 ↗