journal article·2023-06-14Open access

True Non-Contrast Phase versus Virtual-Non Contrast: “Lights and Shadows” of Dual Energy CT Angiography in Peripheral Arterial Disease

Chiara Floridi, Laura Maria Cacioppa, Giacomo Agliata, Michaela Cellina, Nicolo’ Rossini, Tommaso Valeri, Martina Curzi, Alessandro Felicioli, Alessandra Bruno, Marzia Rosati, Roberto Candelari, Andrea Giovagnoni

Applied Sciences· Volume 13· Issue 12

Abstract

(1) Background: The value of dual-energy CT angiography (DE-CTA) in the detection of peripheral arterial disease (PAD) has been widely recognized. We aim to evaluate the diagnostic accuracy of virtual non-contrast (VNC) imaging of DE-CTA compared to true non-contrast phase (TNC). (2) Methods: Our Internal Review Board (IRB) approved prospective study enrolled 40 patients (28 men, 12 women; median age 69 y, range 41–93 y) who underwent lower extremity DE-CTA for symptomatic PAD. Mean attenuation values of TNC and VNC were obtained by placing circular regions of interest (ROI) at five levels from the aortic to the popliteal arterial lumen, reported in Hounsfield units (HU), and compared using a two-sample t-test. The subjective quality of VNC images was assessed by two independent radiologists with 10 and 4 years of CTA-imaging experience according to a 4-point scale and verified by the intra-class correlation coefficient (ICC). Dose Length Product (DLP) values of each DE-CTA examination were also considered. (3) Results: Except for the external iliac artery, VNC attenuation values were significantly lower than the corresponding TNC values at all levels, with a mean difference ranging from 14.1 and 8.7 HU. At qualitative analysis, VNC images were considered excellent to diagnose in 40%, good in 50%, and sufficient in 10% of cases. No cases of non-diagnostic VNC imaging were reported. Avoiding the TNC phase, a mean reduction in DLP of 54% for each DE-CTA was estimated. (4) Conclusions: TNC and VNC images showed comparable reliability and diagnostic accuracy in the detection of PAD. VNC may be considered a promising substitute for TNC from the perspectives of dose reduction and workflow optimization.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Peripheral Artery Disease Management · Advanced X-ray and CT Imaging · Photoacoustic and Ultrasonic Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, 60126 Ancona, Italy

Division of Radiology, Department of Radiological Sciences, University Hospital “Azienda Ospedaliera Universitaria delle Marche”, 60126 Ancona, Italy

Division of Interventional Radiology, Department of Radiological Sciences, University Hospital “Azienda Ospedaliera Universitaria delle Marche”, 60126 Ancona, Italy

Radiology Department, ASST Fatebenefratelli Sacco, 20121 Milan, Italy

UOC Radiology, AST Fermo, Marche Region, 63900 Fermo, Italy

References (45)

Show source-provided references
1. Epidemiology of Peripheral Artery Disease and Polyvascular Disease10.1161/CIRCRESAHA.121.318535 ↗
2. Lower Extremity Peripheral Artery Disease: Contemporary Epidemiology, Management Gaps, and Future Directions: A Scientific Statement from the American Heart Association10.1161/CIR.0000000000001005 ↗
3. Comparison of global estimates of prevalence and risk factors for peripheral artery disease in 2000 and 2010: A systematic review and analysis10.1016/S0140-6736(13)61249-0 ↗
4. 2017 ESC Guidelines on the Diagnosis and Treatment of Peripheral Arterial Diseases, in collaboration with the European Society for Vascular Surgery (ESVS): Document covering atherosclerotic disease of extracranial carotid and vertebral, mesenteric, renal, upper and lower extremity arteriesEndorsed by: The European Stroke Organization (ESO)The Task Force for the Diagnosis and Treatment of Peripheral Arterial Diseases of the European Society of Cardiology (ESC) and of the European Society for Vascular Surgery (ESVS)10.1093/eurheartj/ehx095 ↗
5. Lower extremity CT angiography in peripheral arterial disease: From the established approach to evolving technical developments10.1007/s10554-021-02277-1 ↗
6. Diagnostic Accuracy of Color Doppler and Calcium Scoring versus Dual-Energy Computed Tomography Angiography in the Assessment of Peripheral Arterial Diseases of Lower Limb10.25259/JCIS_77_2020 ↗
7. Have CT and MR angiography replaced catheter angiography in diagnosing peripheral arterial disease?10.1016/j.jacr.2015.04.020 ↗
8. Diagnostic performance of computed tomography angiography in peripheral arterial disease: A systematic review and meta-analysis10.1001/jama.301.4.415 ↗
9. Peripheral arterial occlusive disease: Diagnostic performance and effect on therapeutic management of 64-section CT angiography10.1148/radiol.11103564 ↗
10. Lower extremity computed tomography angiography can help predict technical success of endovascular revascularization in the superficial femoral and popliteal artery10.1016/j.jvs.2017.02.031 ↗
11. Advances in axial imaging of peripheral vascular disease10.1007/s11886-015-0644-2 ↗
12. Epidemiology of peripheral artery disease10.1161/CIRCRESAHA.116.303849 ↗
13. AHA/ACC Guideline on the Management of Patients with Lower Extremity Peripheral Artery Disease: Executive Summary: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines
14. Low-dose multidetector CT angiography in the evaluation of infrarenal aorta and peripheral arterial occlusive disease10.1148/radiol.11110700 ↗
15. Blooming Artifact Reduction in Coronary Artery Calcification by A New De-blooming Algorithm: Initial Study10.1038/s41598-018-25352-5 ↗
16. Modified calcium subtraction in dual-energy CT angiography of the lower extremity runoff: Impact on diagnostic accuracy for stenosis detection10.1007/s00330-019-06032-y ↗
17. Radiation dose and image quality with new protocol in lower extremity computed tomography angiography10.1007/s11547-018-0963-7 ↗
18. Low radiation dose in computed tomography: The role of iodine10.1259/bjr.20170079 ↗
19. Dual-energy spectral CT imaging of pulmonary embolism with Mycoplasma pneumoniae pneumonia in children10.1007/s11547-021-01442-9 ↗
20. Identification of bone marrow edema of the knee: Diagnostic accuracy of dual-energy CT in comparison with MRI10.1007/s11547-020-01267-y ↗
21. Management of vertebral compression fractures: The role of dual-energy CT in clinical practice10.1007/s11547-022-01498-1 ↗
22. Third-generation iterative reconstruction on a dual-source, high-pitch, low-dose chest CT protocol with tin filter for spectral shaping at 100 kV: A study on a small series of COVID-19 patients10.1007/s11547-020-01298-5 ↗
23. Ultra-low-dose chest CT in adult patients with cystic fibrosis using a third-generation dual-source CT scanner10.1007/s11547-020-01304-w ↗
24. Dual-energy CT: Theoretical principles and clinical applications10.1007/s11547-019-01107-8 ↗
25. Applications of dual energy CT in clinical practice: A pictorial essay10.4103/ijri.IJRI_241_19 ↗
26. Quantitative attenuation accuracy of virtual non-enhanced imaging compared to that of true non-enhanced imaging on dual-source dual-energy CT10.1007/s00261-020-02415-8 ↗
27. Dual-energy CT quantification of fractional extracellular space in cirrhotic patients: Comparison between early and delayed equilibrium phases and correlation with oesophageal varices10.1007/s11547-021-01341-z ↗
28. A comprehensive review of dual-energy and multi-spectral computed tomography10.1016/j.clinimag.2020.07.030 ↗
29. Dual-Energy Computed Tomography: Image Acquisition, Processing, and Workflow10.1016/j.rcl.2018.03.001 ↗
30. Assessment of vascular contrast and depiction of stenoses in abdominopelvic and lower extremity vasculature: Comparison of dual-energy MDCT with digital subtraction angiography10.1016/j.acra.2012.04.014 ↗
31. Dual-energy CT angiography in peripheral arterial occlusive disease10.1007/s00270-008-9491-5 ↗
32. Imaging Findings of Peripheral Arterial Disease on Lower-Extremity CT Angiography Using a Virtual Monoenergetic Imaging Algorithm10.3348/jksr.2021.0191 ↗
33. Dual-energy CT angiography in peripheral arterial occlusive disease-accuracy of maximum intensity projections in clinical routine and subgroup analysis10.1007/s00330-011-2099-1 ↗
34. Dual-Energy CTA in Patients with Symptomatic Peripheral Arterial Occlusive Disease: Study of Diagnostic Accuracy and Impeding Factors10.1055/s-0043-101526 ↗
35. Koo, B.J., Won, J.H., Choi, H.C., Na, J.B., Kim, J.E., Park, M.J., Jo, S.H., Park, H.O., Lee, C.E., and Kim, M.J. (2022). Automatic Plaque Removal Using Dual-Energy Computed Tomography Angiography: Diagnostic Accuracy and Utility in Patients with Peripheral Artery Disease. Medicina, 58.10.3390/medicina58101435 ↗
36. Almutairi, A., Sun, Z., Poovathumkadavi, A., and Assar, T. (2015). Dual Energy CT Angiography of Peripheral Arterial Disease: Feasibility of Using Lower Contrast Medium Volume. PLoS ONE, 10.10.1371/journal.pone.0145976 ↗
37. Novel developments in non-invasive imaging of peripheral arterial disease with CT: Experience with state-of-the-art, ultra-high-resolution CT and subtraction imaging10.1016/j.crad.2018.03.002 ↗
38. Extra-abdominal dual-energy CT applications: A comprehensive overview10.1007/s11547-019-01126-5 ↗
39. Editor’s Choice—European Society for Vascular Surgery (ESVS) 2020 Clinical Practice Guidelines on the Management of Acute Limb Ischaemia10.1016/j.ejvs.2019.09.006 ↗
40. Virtual non-contrast images from dual-energy CT angiography of the abdominal aorta and femoral arteries: Comparison with true non-contrast CT images10.1259/bjr.20220378 ↗
41. Iodine removal in intravenous dual-energy CT-cholangiography: Is virtual non-enhanced imaging effective to replace true non-enhanced imaging?10.1016/j.ejrad.2011.01.087 ↗
42. Virtual non-contrast in second-generation, dual-energy computed tomography: Reliability of attenuation values10.1016/j.ejrad.2011.12.011 ↗
43. Reliability of virtual non-contrast computed tomography angiography: Comparing it with the real deal10.1177/2058460118790115 ↗
44. Liver virtual non-enhanced CT with dual-source, dual-energy CT: A preliminary study10.1007/s00330-010-1778-7 ↗
45. Dual-layer spectral computed tomography: Virtual non-contrast in comparison to true non-contrast images10.1016/j.ejrad.2018.05.007 ↗