journal article·2022-08-23Open access

Up-to-Date Optimization of the 90Y-PET/CT Reconstruction Protocol for Volumetric Quantification in Trans-Arterial RadioEmbolization (TARE) Procedures in the Era of Theranostics

Amedeo Capotosti, Roberto Moretti, Alessia Milano, Matteo Nardini, Davide Cusumano, Salvatore Annunziata, Marco Capogni, Marco D’Arienzo, Lorenzo Placidi, Luca Indovina

Applied Sciences· Volume 12· Issue 17

Abstract

(1) Background: New generation of PET-CT scanners allows performing volumetric dosimetry based on 90Y-activity distribution. The aim of this study was to perform an up-to-date evaluation of the optimal 90Y-PET-CT reconstruction parameters for a Siemens Biograph mCT scanner. (2) Methods: A cylindrical uniform phantom (P1), IEC NEMA Body-phantom (P2) and IEC NEMA Torso-phantom (P3) filled with 90Y were acquired. The matrix size and number of Equivalent Iterations (E.I.) were evaluated through the Recovery Coefficient (RC) and the Coefficient of Variation (CoV). The optimal post-reconstruction Gaussian Filter (GF) was assessed through an analysis of Root Mean Square Error (RMSE) and Full Width at Half Maximum (FWHM) in DVHs. (3) Results: For P1, RC values showed constant trends varying the matrix size (slope m = 1.25 × 10−3) or E.I. (slope m = −2.16 × 10−4). For P2, CoV decreased increasing the matrix size and it grew increasing the E.I. For P3, RMSE and mean dose values showed constant trends varying the Gaussian filter (slope m = 1.51 × 10−2) while FWHM decreased increasing filter. For smaller volumes, RMSE grew increasing the filter (from 34% to 74%) and the use of larger filters resulted in a dose underestimation (from 172 to 133 Gy). (4) Conclusions: The optimal reconstruction parameters for the Siemens Biograph mCT PET/CT scanner are presented, combining old metrics with new ones involving a dosimetric approach.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Radiopharmaceutical Chemistry and Applications · Medical Imaging Techniques and Applications · Advanced X-ray and CT Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy

Università Cattolica del Sacro Cuore, 00168 Rome, Italy

UOS Fisica Medica, Mater Olbia Hospital, Strada Statale 125 Orientale Sarda, 07026 Olbia, Italy

ENEA, National Institute of Ionizing Radiation Metrology, 00123 Rome, Italy

References (29)

Show source-provided references
1. Selective internal radiation therapy with SIR-spheres for the treatment of unresectable colorectal hepatic metastases10.1007/s00270-009-9658-8 ↗
2. Yttrium-90 microspheres: Radiation therapy for unresectable liver cancer10.1016/S1051-0443(07)61790-4 ↗
3. Radioembolization plus chemotherapy for first-line treatment of locally advanced intrahepatic cholangiocarcinoma: A phase 2 clinical trial10.1001/jamaoncol.2019.3702 ↗
4. LBA21 Radioembolization with chemotherapy for colorectal liver metastases: A randomized, open-label, international, multicenter, phase III trial (EPOCH study)10.1016/j.annonc.2021.08.2095 ↗
5. Recommendations of the American association of physicists in medicine on dosimetry, imaging, and quality assurance procedures for 90Y microsphere brachytherapy in the treatment of hepatic malignancies10.1118/1.3608909 ↗
6. Practical reconstruction protocol for quantitative 90Y bremsstrahlung SPECT/CT10.1118/1.4960629 ↗
7. Yttrium-90-labeled microsphere tracking during liver selective internal radiotherapy by bremsstrahlung pinhole SPECT: Feasibility study and evaluation in an abdominal phantom10.1186/2191-219X-1-32 ↗
8. Comparison of quantitative Y-90 SPECT and non-time-of-flight PET imaging in post-therapy radioembolization of liver cancer10.1118/1.4962472 ↗
9. A new internal pair production branching ratio of 90Y: The development of a non-destructive assay for 90Y and 90Sr10.1016/j.apradiso.2006.08.009 ↗
10. Clinical feasibility of 90 Y digital PET/CT for imaging microsphere biodistribution following radioembolization10.1007/s00259-017-3694-4 ↗
11. Elschot, M., Vermolen, B.J., Lam, M.G., de Keizer, B., van den Bosch, M.A., and de Jong, H.W. (2013). Quantitative comparison of PET and Bremsstrahlung SPECT for imaging the in vivo yttrium-90 microsphere distribution after liver radioembolization. PLoS ONE, 8.10.1371/journal.pone.0055742 ↗
12. PET optimization for improved assessment and accurate quantification of 90Y-microsphere biodistribution after radioembolization10.1118/1.4892383 ↗
13. Phantom validation of quantitative Y-90 PET/CT-based dosimetry in liver radioembolization10.1186/s13550-017-0341-9 ↗
14. Update on novel trends in PET/CT technology and its clinical applications10.1259/bjr.20160534 ↗
15. 90Y-PET/CT-based dosimetry after selective internal radiation therapy predicts outcome in patients with liver metastases from colorectal cancer10.1186/s13550-018-0419-z ↗
16. Dose-response and dose-toxicity relationships for glass 90Y radioembolization in patients with liver metastases from colorectal cancer10.2967/jnumed.120.255745 ↗
17. Quantitative 90Y image reconstruction in PET10.1118/1.4762403 ↗
18. A multicentre comparison of quantitative 90 Y PET/CT for dosimetric purposes after radioembolization with resin microspheres10.1007/s00259-015-3059-9 ↗
19. Assessment of acquisition protocols for routine imaging of Y-90 using PET/CT10.1186/2191-219X-3-11 ↗
20. Attarwala, A.A., Molina-Duran, F., Büsing, K.A., Schönberg, S.O., Bailey, D.L., Willowson, K., and Glatting, G. (2014). Quantitative and qualitative assessment of yttrium-90 PET/CT imaging. PLoS ONE, 9.10.1371/journal.pone.0110401 ↗
21. Dose volume histogram-based optimization of image reconstruction parameters for quantitative 90Y-PET imaging10.1002/mp.13269 ↗
22. Construction and implementation of a TDCR system at ENEA10.1016/j.apradiso.2013.11.014 ↗
23. A full digital approach to the TDCR method10.1016/j.apradiso.2013.11.103 ↗
24. A review of the triple-to-double coincidence ratio (TDCR) method for standardizing radionuclides10.1016/S0969-8043(03)00056-3 ↗
25. MIRD pamphlet no. 17: The dosimetry of nonuniform activity distributions—Radionuclide S values at the voxel level
26. Determination of radiation absorbed dose to primary liver tumors and normal liver tissue using post-radioembolization 90Y PET10.3389/fonc.2014.00255 ↗
27. Feasibility of 90 Y TOF PET-based dosimetry in liver metastasis therapy using SIR-Spheres10.1007/s00259-010-1470-9 ↗
28. Post-radioembolization yttrium-90 PET/CT-part 2: Dose-response and tumor predictive dosimetry for resin microspheres
29. Comparison of the biograph vision and biograph mCT for quantitative 90Y PET/CT imaging for radioembolisation10.1186/s40658-020-0283-6 ↗