journal article·2023-05-19Open access

Response Time of a Thin-Film Resistance Temperature Detector (RTD) for High-Intensity Focused Ultrasound (HIFU) Phantom Applications

Ma. Stella Grace B. Lequiron, Daniel J. Joe, Sun Do Lim, Il Doh

Applied Sciences· Volume 13· Issue 10

Abstract

The thermal response time of a thin-film resistance temperature detector (RTD) array sensor was measured for a high-intensity focused ultrasound (HIFU) phantom. As the temperature inside materials change rapidly within several seconds, it is important to have a temperature sensor with a fast response time to evaluate their performance. However, previous methods for measuring thermal response time were not suitable for thin-film sensors, and there were no quantitative data available. In this study, we used a liquid drop method to measure the thermal time constant of the thin-film RTD, which was found to be 1.0 ± 0.2 ms. This indicates that the thin-film RTD array sensor has a sufficiently fast response time to detect sudden temperature changes inside the tissue-mimicking material (TMM) for validating HIFU devices.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Photoacoustic and Ultrasonic Imaging · Ultrasound and Hyperthermia Applications · Infrared Thermography in Medicine

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Safety Measurement Institute, Korea Research Institute of Standards and Science (KRISS), Daejeon 34113, Republic of Korea

Department of Applied Measurement Science, University of Science and Technology (UST), Daejeon 34113, Republic of Korea

Photometry and Radiometry Group, Division of Physical Metrology, Korea Research Institute of Standards and Science (KRISS), Daejeon 34113, Republic of Korea

Funding

Korea Research Institute of Standards and Science · Ministry of Trade, Industry, and Energy, the Ministry of Health and Welfare, Republic of Korea, and the Ministry of Food and Drug Safety · Ministry of Science and ICT (MSIT)

References (18)

Show source-provided references
1. High Intensity Focused Ultrasound: Physical Principles and Devices10.1080/02656730601186138 ↗
2. Drug Delivery across the Blood-Brain Barrier Using Focused Ultrasound10.1517/17425247.2014.897693 ↗
3. High Intensity Focused Ultrasound in Clinical Tumor Ablation10.5306/wjco.v2.i1.8 ↗
4. High Intensity Focused Ultrasound (HIFU) Ablation of Benign Thyroid Nodules—A Systematic Review10.1186/s40349-017-0091-1 ↗
5. Focused Ultrasound: Tumour Ablation and Its Potential to Enhance Immunological Therapy to Cancer10.1259/bjr.20170641 ↗
6. Lafond, M., Lambin, T., Drainville, R.A., Dupré, A., Pioche, M., Melodelima, D., and Lafon, C. (2022). Pancreatic Ductal Adenocarcinoma: Current and Emerging Therapeutic Uses of Focused Ultrasound. Cancers, 14.10.3390/cancers14112577 ↗
7. Simultaneous Evaluation of Thermal and Non-Thermal Effects of High-Intensity Focused Ultrasound on a Tissue-Mimicking Phantom10.1016/j.ultrasmedbio.2018.03.024 ↗
8. Thin-Film Resistance Temperature Detector Array for the Measurement of Temperature Distribution inside a Phantom10.1088/1681-7575/aa90bd ↗
9. Proposed Standard Thermal Test Object for Medical Ultrasound
10. A Tissue Mimicking Polyacrylamide Hydrogel Phantom for Visualizing Thermal Lesions Generated by High Intensity Focused Ultrasound10.1016/j.ultrasmedbio.2012.10.002 ↗
11. Experimental Evaluation of Targeting Accuracy of Ultrasound Imaging-Guided Robotic HIFU Ablative System for the Treatment of Solid Tumors in Pre-Clinical Studies10.1016/j.apacoust.2021.108367 ↗
12. Development of a High-Field MR-Guided HIFU Setup for Thermal and Mechanical Ablation Methods in Small Animals10.1186/s40349-015-0035-6 ↗
13. Focused Ultrasound Thermometry: A Two-Dimensional Resistance Temperature Detector Array in a Tissue-Mimicking Material10.1109/JSEN.2021.3116589 ↗
14. Response Time Testing of Temperature Sensors Using Loop Current Step Response Method10.1504/IJNEST.2013.052164 ↗
15. A Fast-Response Thin Film Thermocouple to Measure Rapid Surface Temperature Changes10.1016/j.expthermflusci.2005.05.004 ↗
16. Development of Fast Response Heat Transfer Measurement Technique with Thin-Film Thermocouples10.1016/j.ijheatmasstransfer.2020.120331 ↗
17. HIFU Treatment Time Reduction in Superficial Tumours through Focal Zone Path Selection10.3109/02656736.2011.564597 ↗
18. MRI-Guided Focused Ultrasound Surgery of Uterine Leiomyomas10.1016/j.acra.2005.05.018 ↗