Multi-Objective Optimal D-PMU Placement for Fast, Reliable and High-Precision Observations of Active Distribution Networks
Source abstract
Abstract
The distribution-level phasor measurement unit(D-PMU), as a new type of measurement equipment, can support the fast and high-precision observations of active distribution networks. This paper presents a new D-PMU optimal placement method that can be used to reconcile investments with the reliability of high-precision observation systems. The multi-objective optimization model primarily considers the influence of topology changes and N-1 contingencies on observation reliability. Its objectives include minimizing the number of D-PMUs, maximizing network measurement redundancy (NMR) and the average number of observable buses under N-1 contingencies (ANOBC). The model is extended to a form of multi-topology weighting and is combined with zero-injection buses and other measurements. We take the observability of high-weight topology set as the constraint. The model can be solved using the non-dominated sorting genetic algorithm-III (NSGA-III), which gives the set of Pareto optimal solutions. Then, the D-PMU placement order determination method based on the spatial electrical distance is proposed to improve the effect of state estimation faster. IEEE standard systems are taken to verify the effectiveness of the proposed method. With the same number of D-PMUs, this method derives more ANOBC and NMR than other methods. When considering topology changes, the proposed method can use fewer additional D-PMUs to substantially increase the ANOBC and NMR.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Optimal Power Flow Distribution · Power System Optimization and Stability · Electric Power System Optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Key Laboratory of Intelligent Power Grid Ministry of Education, Tianjin University, Tianjin 300072, China
Electric Power Research Institute State Grid Hubei Electric Power, Wuhan 430077, China
Funding
Science and Technology Project of the State Grid Corporation of China
References (33)
Show source-provided references
1. Fault Location Technology for Power System Based on Information about the Power Internet of Things10.1109/TII.2019.2960440 ↗
2. Ahmed, M.M., Amjad, M., Qureshi, M.A., Imran, K., Haider, Z.M., and Khan, M.O. (2022). A Critical Review of State-of-the-Art Optimal PMU Placement Techniques. Energies, 15.10.3390/en15062125 ↗
3. Synchrophasor measurement applications and optimal D-PMU placement: A review10.1016/j.epsr.2021.107428 ↗
4. Lambrou, C., Mandoulidis, P., and Vournas, C. (2021). Validation of Voltage Instability Detection and Control Using a Real Power System Incident. Energies, 14.10.3390/en14217165 ↗
5. Lee, K.-Y., Park, J.-S., and Kim, Y.-S. (2021). Optimal Placement of D-PMU to Enhance Supervised Learning-Based Pseudo-Measurement Modelling Accuracy in Distribution Network. Energies, 14.10.3390/en14227767 ↗
6. Placement of Distribution-Level Phasor Measurements for Topological Observability and Monitoring of Active Distribution Networks10.1109/TIM.2019.2939951 ↗
7. Multistage Optimal D-PMU Placement Considering Substation Infrastructure10.1109/TIA.2018.2862401 ↗
8. D-PMU placement considering various arrangements of lines connections at complex buses10.1016/j.ijepes.2017.06.028 ↗
9. Optimization of Phasor Measurement Units Placement Under Contingency Using Reliability of Network Components10.1109/TIM.2020.3004680 ↗
10. Kong, X., Wang, Y., Yuan, X., and Yu, L. (2019). Multi Objective for D-PMU Placement in Compressed Distribution Network Considering Cost and Accuracy of State Estimation. Appl. Sci., 9.10.3390/app9071515 ↗
11. Optimal Allocation of Phasor Measurement Units Considering Various Contingencies and Measurement Redundancy
12. Optimal D-PMU placement approach for power systems considering non-Gaussian measurement noise statistics10.1016/j.ijepes.2020.106577 ↗
13. Integrated Model Considering Effects of Zero Injection Buses and Conventional Measurements on Optimal D-PMU Placement
14. Optimal PMU Placement for Numerical Observability Considering Fixed Channel Capacity—A Semidefinite Programming Approach10.1109/TPWRS.2015.2490599 ↗
15. Optimal D-PMU Placement Considering load loss and Relaying in Distribution Networks10.1109/ACCESS.2018.2841891 ↗
16. D-PMU Placement Protection Against Coordinated False Data Injection Attacks in Smart Grid
17. A Novel Multiobjective OPP for Power System Small Signal Stability Assessment Considering WAMS Uncertainties10.1109/TII.2019.2911397 ↗
18. Optimal D-PMU Placement for Power System Observability Considering Network Expansion and N-1 Contingencies
19. An optimal joint placement of D-PMUs and flow measurements for ensuring power system observability under N-2 transmission contingencies10.1016/j.ijepes.2017.08.025 ↗
20. PMU Placement for Measurement Redundancy Distribution Considering Zero Injection Bus and Contingencies10.1109/JSYST.2020.2990435 ↗
21. State Estimation Method for Active Distribution Networks Under Environment of Hybrid Measurements with Multiple Sampling Periods
22. Power Loss Minimization in Distribution System Using Network Reconfiguration in the Presence of Distributed Generation10.1109/TPWRS.2012.2197227 ↗
23. Study of Reconfiguration for the Distribution System with Distributed Generators10.1109/TPWRD.2010.2046339 ↗
24. Nara, K., Mishima, Y., and Satoh, T. (2003, January 13–17). Network reconfiguration for loss minimization and load balancing. Proceedings of the 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No. 03CH37491), Toronto, ON, Canada.
25. Network reconfiguration in distribution systems for loss reduction and load balancing10.1109/61.25627 ↗
26. Conditional Residual Modeling for Probabilistic Load Forecasting10.1109/TPWRS.2018.2868167 ↗
27. An Evolutionary Many-Objective Optimization Algorithm Using Reference-Point-Based Nondominated Sorting Approach, Part I: Solving Problems With Box Constraints10.1109/TEVC.2013.2281535 ↗
28. An Evolutionary Many-Objective Optimization Algorithm Using Reference-Point Based Nondominated Sorting Approach, Part II: Handling Constraints and Extending to an Adaptive Approach10.1109/TEVC.2013.2281534 ↗
29. A New Dominance Relation-Based Evolutionary Algorithm for Many-Objective Optimization10.1109/TEVC.2015.2420112 ↗
30. Developing a fuzzy TOPSIS approach based on subjective weights and objective weights10.1016/j.eswa.2008.11.035 ↗
31. Distributed State Estimation for Distribution Network with Phasor Measurement Units Information10.1016/j.egypro.2019.01.820 ↗
32. Abdelsalam, H.A., Abdelaziz, A.Y., Osama, R.A., and Salem, R.H. (2014, January 11–14). Impact of Distribution System Reconfiguration on Optimal Placement of Phasor Measurement Units. Proceedings of the 2014 Clemson University Power Systems Conference (PSC), Clemson, SC, USA.10.1109/PSC.2014.6808114 ↗
33. Optimal placement of D-PMUs using adaptive genetic algorithm considering measurement redundancy. International Journal of Reliability