Exergy-Based Thermo-Hydraulic Performance of Roughened Absorber in Solar Air Heater Duct
Source abstract
Abstract
This paper presents the thermo-hydraulic performance of small conical ribs on the absorber plate of a solar energy air heater (SAH) using exergy analysis. Application of conical protrusion ribs on the absorber is an attractive solution for enhancing the thermal performance of a SAH. However, these ribs are also responsible for high friction losses and increased fan power consumption caused by the turbulent air flow. To optimize the rib design, it is vital to consider both thermal and hydraulic performance at the same time. The SAH was assessed using an analytic method which predicts the exergy efficiency under operating parameters (e.g., Reynolds number, solar insolation and temperature increase parameter). The following geometric quantities of ribs were evaluated for optimum exergy efficiency: the relative rib height (e/D), which was in the range between 0.200 and 0.044, and the relative rib pitch (p/e), which was in the range between 6 and 12. The combination of a relative rib height of 0.044 and relative rib pitch of 10 exhibits the highest exergy efficiency of 0.0202. The optimization of the rib geometric quantities parameters was performed by considering the temperature increase parameter, aiming to achieve maximum exergy efficiency. The combination of rib parameters e/D = 0.044 and p/e = 10 are noted to yield best performance when operating at a temperature increase parameter above 0.0141 K∙m2/W.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Heat Transfer Mechanisms · Fluid Dynamics and Turbulent Flows · Aerodynamics and Fluid Dynamics Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
CSIR-Central Building Research Institute Roorkee, Roorkee 247667, India
Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
Mechanical Engineering Department, King Saud University, Riyadh 11421, Saudi Arabia
Department of Industrial Engineering, College of Engineering, Prince Sattam Bin Abdulaziz University, Al-Kharj 16273, Saudi Arabia
Faculty of Engineering, University of Rijeka, 51000 Rijeka, Croatia
Department of Mechanical Engineering, Gautam Buddha University, Greater Noida 201312, India
References (31)
Show source-provided references
1. Duffie, J.A., and Beckman, W.A. (1991). Solar Engineering Thermal Processes, John Wiley.
2. Heat and flow characteristics of air heater ducts provided with turbulators—A review10.1016/j.rser.2013.11.050 ↗
3. Use of turbulators for heat transfer augmentation in an air duct–A review10.1016/j.renene.2013.08.024 ↗
4. Alam, T., Balam, N.B., Kulkarni, K.S., Siddiqui, M.I.H., Kapoor, N.R., Meena, C.S., Kumar, A., and Cozzolino, R. (2021). Performance Augmentation of the Flat Plate Solar Thermal Collector: A Review. Energies, 14.10.3390/en14196203 ↗
5. A critical review on artificial roughness provided in rectangular solar air heater duct10.1016/j.rser.2016.11.192 ↗
6. Optimal thermohydraulic performance of artficially roughened solar air heaters10.1016/0038-092X(91)90039-Y ↗
7. Effect of artificial roughness on heat transfer and friction factor in a solar air heater10.1016/0038-092X(88)90058-8 ↗
8. Heat and fluid flow in rectangular solar air heater ducts having transverse rib roughness on absorber plates10.1016/0038-092X(93)90039-Q ↗
9. Heat transfer and friction in solar air heater duct with V-shaped rib roughness on absorber plate10.1016/S0017-9310(02)00046-7 ↗
10. Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with multiple v-ribs10.1016/j.solener.2010.02.004 ↗
11. Exergy based analysis of solar air heater having discrete V-down rib roughness on absorber plate10.1016/j.energy.2011.09.040 ↗
12. Experimental investigation on heat transfer and fluid flow characteristics of air flow in a rectangular duct with Multi v-shaped rib with gap roughness on the heated plate10.1016/j.solener.2012.03.014 ↗
13. Experimental and CFD investigation of convection heat transfer in solar air heater with reverse L-shaped ribs10.1016/j.solener.2016.02.040 ↗
14. Performance evaluation and optimization of solar assisted air heater with discrete multiple arc shaped ribs10.1016/j.est.2019.100978 ↗
15. Evaluation of the performance of an improved solar air heater with “S” shaped ribs with gap10.1016/j.solener.2019.11.034 ↗
16. Effect of chamfering on heat transfer and friction characteristics of solar air heater having absorber plate roughened with compound turbulators10.1016/j.renene.2008.09.016 ↗
17. Heat transfer and friction characteristics for artificially roughened ducts10.1016/j.ijheatmasstransfer.2007.02.042 ↗
18. Heat transfer and friction characteristics of rectangular solar air heater duct using rib-grooved artificial roughness10.1016/j.solener.2005.08.006 ↗
19. Juarker, A.R. (2005). Heat and fluid flow characteristics of rib-groove artificially roughened solar air heater. Indian Inst. Technol. Roorkee.
20. Effect of circularity of perforation holes in V-shaped blockages on heat transfer and friction characteristics of rectangular solar air heater duct10.1016/j.enconman.2014.06.050 ↗
21. Heat Transfer Enhancement due to V-Shaped Perforated Blocks in a Solar Air Heater Duct10.4028/www.scientific.net/AMM.619.125 ↗
22. Heat transfer and friction factor correlations for a duct having dimple-shape artificial roughness for solar air heaters10.1016/j.energy.2008.02.017 ↗
23. Correlations for solar air heater duct with dimpled shape roughness elements on absorber plate10.1016/j.solener.2012.06.024 ↗
24. Heat transfer and friction characteristics of dimple-shaped roughness element arranged in angular fashion (arc) on the absorber plate of solar air heater10.1063/1.3700191 ↗
25. Nusselt number and friction factor correlations for solar air heater duct having artificially roughened absorber plate10.1016/j.solener.2011.03.007 ↗
26. Thermal performance investigation of the flat and spherical dimple absorber plate solar air heaters10.1016/j.solener.2019.09.066 ↗
27. Nusselt number and friction factor correlations for solar air heater duct having protrusions as roughness elements on absorber plate10.1016/j.expthermflusci.2012.05.011 ↗
28. Heat transfer enhancement in solar air heater duct with conical protrusion roughness ribs10.1016/j.applthermaleng.2017.07.181 ↗
29. Thermo-hydraulic performance analysis of solar air heaters having artificial roughness–A review10.1016/j.rser.2014.08.051 ↗
30. Second law optimization of plat-plate solar air heaters10.1016/0038-092X(88)90128-4 ↗
31. Approximate method for computation of glass cover temperature and top heat-loss coefficient of solar collectors with single glazing10.1016/S0038-092X(99)00032-8 ↗