journal article·2021-10-29Open access

Prescribed Performance Control for the Upper-Limb Exoskeleton System in Passive Rehabilitation Training Tasks

Zhirui Zhao, Jichun Xiao, Hongyun Jia, Hang Zhang, Lina Hao

Applied Sciences· Volume 11· Issue 21

Abstract

In this study, a model-free adaptive sliding mode control method was developed in combination with the prescribed performance method. On this basis, this study attempted to fulfill the joint position tracking trajectory task for the one-degree of freedom (DOF) upper-limb exoskeleton in passive robot-assisted rehabilitation. The proposed method is capable of addressing the defect of the initial error in the controller design and the application by adopting a tuning function, as compared with other prescribed performance methods. Moreover, the method developed here was not determined by the dynamic model parameters, which merely exploit the input and output data. Theoretically, the stability exhibited by the proposed controller and the tracking performance can be demonstrated. From the experimental results, the root mean square of the tracking error is equal to 1.06 degrees, and the steady-state tracking error converges to 1.91 degrees. These results can verify the expected performance of the developed control method.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Prosthetics and Rehabilitation Robotics · Stroke Rehabilitation and Recovery · Spinal Cord Injury Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical Engineering and Automation, Northeastern University, Shenyang 110819, China

Funding

National Natural Science Foundation of China

References (47)

Show source-provided references
1. Upper-Limb Powered Exoskeleton Design10.1109/TMECH.2007.901934 ↗
2. Design and fabrication of a lower limb exoskeleton to assist in stair ascending10.1108/IR-09-2018-0199 ↗
3. Human–robot cooperation control based on a dynamic model of an upper limb exoskeleton for human power amplification10.1016/j.mechatronics.2014.01.007 ↗
4. Voice controlled upper body exoskeleton: A development for industrial application
5. Ghan, J., and Kazerooni, H. (2006, January 15–19). System identification for the berkeley lower extremity exoskeleton (bleex). Proceedings of the International Conference on Robotics and Automation, Orlando, FL, USA.10.1163/156855306778394012 ↗
6. Design and control of the mindwalker exoskeleton10.1109/TNSRE.2014.2365697 ↗
7. Exoskeleton robots for upper-limb rehabilitation: State of the art and future prospects10.1016/j.medengphy.2011.10.004 ↗
8. Gopura, R.A.R.C., and Kiguchi, K. (2008, January 12–14). Development of a 6 DOF Exoskeleton Robot for Human Upper-Limb Motion Assist. Proceedings of the International Conference on Information and Automation for Sustainability, Colombo, Sri Lanka.10.1109/ICIAFS.2008.4783986 ↗
9. Design of a Haptic Arm Exoskeleton for Training and Rehabilitation10.1109/TMECH.2006.875558 ↗
10. NEUROExos: A Powered Elbow Exoskeleton for Physical Rehabilitation10.1109/TRO.2012.2211492 ↗
11. Wang, X., Li, X., and Wang, J. (2015, January 21). Modeling and Identification of the Human-Exoskeleton Interaction Dynamics for Upper Limb Rehabilitation. Proceedings of the Chinese Intelligent Automation Conference, Beijing, China.10.1007/978-3-662-46466-3_6 ↗
12. Stroke rehabilitation: Recent advances and future therapies
13. Design and evaluation of a 7-DOF cable-driven upper limb exoskeleton10.1007/s12206-018-0136-y ↗
14. Prescribed performance model-free adaptive terminal sliding mode control for the pneumatic artificial muscles elbow exoskeleton10.1007/s12206-021-0639-4 ↗
15. Iterative learning control applied to a hybrid rehabilitation exoskeleton system powered by PAM and FES10.1007/s10586-017-0880-x ↗
16. Dynamic analysis of pneumatic artificial muscle (PAM) actuator for rehabilitation with principal parametric resonance condition10.1007/s11071-019-05122-2 ↗
17. A New Soft Pneumatic Elbow Pad for Joint Assistance With Application to Smart Campus10.1109/ACCESS.2018.2852757 ↗
18. Noda, T., Teramae, T., Ugurlu, B., and Morimoto, J. (2014, January 14–18). Development of an upper limb exoskeleton powered via pneumatic electric hybrid actuators with bowden cable. Proceedings of the IROS, Chicago, IL, USA.10.1109/IROS.2014.6943062 ↗
19. Modeling and control of a curved pneumatic muscle actuator for wearable elbow exoskeleton10.1016/j.mechatronics.2008.02.006 ↗
20. Advanced rehabilitation device based on artificial muscle actuators with neural network implementation
21. Design and Evaluation of the RUPERT Wearable Upper Extremity Exoskeleton Robot for Clinical and In-Home Therapies10.1109/TSMC.2015.2497205 ↗
22. Identification of pneumatic artificial muscle manipulators by a MGA-based nonlinear NARX fuzzy model10.1016/j.mechatronics.2008.06.004 ↗
23. Sarosi, J. (2014, January 15–17). Accurate positioning of pneumatic artificial muscle at different temperatures using LabVIEW based sliding mode controller. Proceedings of the IEEE International Symposium on Applied Computational Intelligence and Informatics, Timisoara, Romania.10.1109/SACI.2014.6840040 ↗
24. Variable stiffness structural design of a dual-segment continuum with independent stiffness and angular position10.1016/j.rcim.2020.102000 ↗
25. A novel learning adaptive hysteresis inverse compensator for pneumatic artificial muscles10.1088/1361-665X/ab4b84 ↗
26. Measurement and modeling of Mckibben pneumatic artificial muscles10.1109/70.481753 ↗
27. Comparison of model-based approaches to the compensation of hysteresis in the force characteristic of pneumatic muscles10.1109/TIE.2013.2287217 ↗
28. A new approach to modeling hysteresis in a pneumatic artificial muscle using the maxwell-slip model10.1109/TMECH.2009.2038373 ↗
29. Stable control of force, position, and stiffness for robot joints powered via pneumatic muscles10.1109/TII.2019.2916228 ↗
30. Finite-Element Modeling and Design of a Pneumatic Braided Muscle Actuator With Multifunctional Capabilities10.1109/TMECH.2018.2877125 ↗
31. Robinson, R.M., Kothera, C.S., and Wereley, N.M. (2013, January 11–13). Nonlinear analysis of quasi-static response of pneumatic artificial muscles for agonistic and antagonistic actuation modes. Proceedings of the SPIE Bioinspiration, Biomimetics, and Bioreplication, San Diego, CA, USA.10.1117/12.2012359 ↗
32. Study on mechanicalbehaviors of pneumatic artificial muscle10.1016/j.ijengsci.2009.08.001 ↗
33. Neural-network-based nonlinear model predictive tracking control of a pneumatic muscle actuator-driven exoskeleton10.1109/JAS.2020.1003351 ↗
34. Gao, X., Li, X., Sun, Y., Hao, L., Yang, H., and Xiang, C. (2020). Model-free tracking control of continuum manipulators with global stability and assigned accuracy. IEEE Trans. Syst. Man Cybern. Syst., 1–11.
35. Liang, G., Ye, W., and Xie, Q. (2012, January 5–8). PID control for the robotic exoskeleton: Application to lower extremity rehabilitation. Proceedings of the IEEE International Conference on Mechatronics and Automation, Chengdu, China.10.1109/ICMA.2012.6285711 ↗
36. Roy, R., Islam, M., Rashid, M., Mounis, S., Ahsan, M.M., Ahad, M.T., Siddique, Z., Kouzani, A.Z., and Mahmud, M.A.P. (2021). Investigation of 2DOF PID Controller for Physio-Therapeutic Application for Elbow Rehabilitation. Appl. Sci., 11.10.3390/app11188617 ↗
37. Zawawi, M., Elamvazuthi, I., Aziz, A., and Da Ud, S.A. (2017, January 19–21). Comparison of PID and fuzzy logic controller for DC servo motor in the development of lower extremity exoskeleton for rehabilitation. Proceedings of the IEEE International Symposium in Robotics and Manufacturing Automation, Kuala, Lumpur.10.1109/ROMA.2017.8231822 ↗
38. Liu, M., Zhao, Z., and Hao, L. (2021). Prescribed performance model-free adaptive sliding mode control of a shape memory alloy actuated system. ISA Trans., in press.10.1016/j.isatra.2021.05.021 ↗
39. From model-based control to data-driven control: Survey, classification and perspective10.1016/j.ins.2012.07.014 ↗
40. Model-free adaptive integral terminal sliding mode predictive control for a class of discrete-time nonlinear systems10.1016/j.isatra.2019.02.033 ↗
41. Research on PSA-MFAC for a novel bionic elbow joint system actuated by pneumatic artificial muscles10.1007/s12206-017-0640-0 ↗
42. Espinoza-Fraire, T., Saenz, A., Salas, F., Juarez, R., and Giernacki, W. (2021). Trajectory Tracking with Adaptive Robust Control for Quadrotor. Appl. Sci., 11.10.3390/app11188571 ↗
43. Data-driven model-free adaptive sliding mode control for the multi degree-of-freedom robotic exoskeleton10.1016/j.ins.2015.08.025 ↗
44. Robust adaptive control of feedback linearizable MIMO nonlinear systems with prescribed performance10.1109/TAC.2008.929402 ↗
45. Data-Driven Adaptive Sliding Mode Control of Nonlinear Discrete-Time Systems With Prescribed Performance10.1109/TSMC.2017.2779564 ↗
46. Sliding order and sliding accuracy in sliding mode control10.1080/00207179308923053 ↗
47. Teramae, T., Noda, T., Hyon, S.H., and Morimoto, J. (2013, January 3–8). Modeling and control of a Pneumatic-Electric hybrid system. Proceedings of the IEEE/RSJ International Conference on Intelligent Robots & Systems, Tokyo, Japan.10.1109/IROS.2013.6697061 ↗