A Randomized Controlled Trail for Comparing LED Color Temperature and Color Rendering Attributes in Different Illuminance Environments for Human-Centric Office Lighting
Source abstract
Abstract
In this study, two experiments were conducted to investigate the effects of the color rendering index (CRI) and correlated color temperature (CCT) of light-emitting diode (LED) lighting on office user acceptance and to explore the proper color attributes for human-centric office lighting. Experiment 1 had four LED lights, with two levels for the CRI (CRI < 80: 79, 76; or CRI ≥ 80: 83, 84) and CCT (3000 K or 6500 K) at 300 lux. In experiment 2, there were four LED lights, with several levels for the CRI (CRI < 80: 78; or CRI ≥ 80: 87, 83) and CCT (3000 K or 6500 K) at 500 lux. Ninety-six participants in experiment 1 and ninety-four participants in experiment 2 performed a reading task. The results in experiment 1 and experiment 2 showed that LEDs with lower CRI values at warm color temperatures were rated as more acceptable than LEDs with higher CRI values at warm color temperatures. However, the positive effect extended to LEDs with higher CRI values at cool temperatures but not to LEDs with lower CRI values at cool temperatures. Therefore, the findings are that LEDs with lower CRI values at warm color temperatures and LEDs with higher CRI values at cool temperatures provide the right level of color attributes for office lighting.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Impact of Light on Environment and Health · Color perception and design · Color Science and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Architecture, Hongik University, 94 Wausan-ro, Mapo-gu, Seoul 04066, Korea
Funding
National Research Foundation of Korea
References (50)
Show source-provided references
1. CIE (2019). Position Statement on Non-Visual Effects of Light—Recommending Proper Light at the Proper Time, CIE Central Bureau. [2nd ed.].
2. Human-centric lighting: Myth, magic or metaphor?10.1177/1477153520958448 ↗
3. Phototransduction by retinal ganglion cells that set the circadian clock10.1126/science.1067262 ↗
4. Strange vision: Ganglion cells as circadian photoreceptors10.1016/S0166-2236(03)00130-9 ↗
5. IES (2018). TM-18-18-Light and Human Health: An Overview of the Impact of Optical Radiation on Visual, Circadian, Neuroendocrine and Neurobehavioral Responses, IES.
6. Measuring and using light in the melanopsin age10.1016/j.tins.2013.10.004 ↗
7. CIE Central Bureau (2018). CIE S 026:2018-CIE System for Metrology of Optical Radiation for ipRGC—Influenced Responses to Light, CIE Central Bureau.
8. Circadian light10.1186/1740-3391-8-2 ↗
9. Modelling the spectral sensitivity of the human circadian system10.1177/1477153511430474 ↗
10. Neberich, M., and Opferkuch, F. (2021). Standardizing Melanopic Effects of Ocular Light for Ecological Lighting Design of Nonresidential Buildings—An Overview of Current Legislation and Accompanying Scientific Studies. Sustainability, 13.10.3390/su13095131 ↗
11. German Institute for Standardisation (2021). DIN/TS 5031-100:2021, Optical Radiation Physics and Illuminating Engineering—Melanopic Effects of Ocular Light on Human Beings—Quantities, Symbols and Action Spectra, German Institute for Standardisation.
12. IWBI (2021, August 27). WELL Building Standard. LIGHT. WELL v2. Q2 2021. Available online: https://standard.wellcertified.com/well.
13. UL (2020). Design Guidelines for Promoting Circadian Entrainment with Light for Day-Active People, UL. [1st ed.].
14. Babilon, S., Beck, S., Kunkel, J., Klabes, J., Myland, P., Benkner, S., and Khanh, T.Q. (2021). Measurement of Circadian Effectiveness in Lighting for Office Applications. Appl. Sci., 11.10.3390/app11156936 ↗
15. Higher light intensity induces modulations in brain activity even during regular daytime working hours10.1177/1477153515576399 ↗
16. User acceptance studies for LED office lighting: Lamp spectrum, spatial brightness and illuminance10.1177/1477153513514425 ↗
17. User acceptance studies for LED office lighting: Preference, naturalness and colourfulness10.1177/1477153513514424 ↗
18. ISO (2002). ISO 8995-1: 2002-Lighting of Indoor Work Places—Part 1, ISO.
19. CIE (1995). CIE 13.3: 1995-Method of Measuring and Specifying Colour Rendering Properties of Light Sources, CIE.
20. CIE (2004). CIE 15:2004-Colorimetry, CIE. [3rd ed.].
21. IESNA (2011). The Lighting Handbook: Reference and Application, IESNA. [10th ed.].
22. BAuA (2021, September 05). ASR A3.4 Beleuchtung-Technische Regel für Arbeitsstätten. Available online: https://www.baua.de/DE/Angebote/Rechtstexte-und-Technische-Regeln/Regelwerk/ASR/ASR-A3-4.html.
23. Influence of the colour temperature of the preferred lighting level in an industrial work area devoid of daylight
24. An experimental study on the appraisal of the visual environment at offices in relation to colour temperature and illuminance10.1016/j.buildenv.2005.10.022 ↗
25. Influence of color temperature on comfort and preference for LED indoor lighting10.1016/j.ijleo.2016.10.049 ↗
26. CIE (2017). CIE 224: 2017-Colour Fidelity Index for Accurate Scientific Use, CIE.
27. IES (2020). ANSI/IES TM-30-20-IES Method for Evaluating Light Source Color Rendition, IES.
28. Color preference under LEDs with diminished yellow emission
29. A test of the S/P ratio as a correlate for brightness perception using rapid-sequential and side-by-side experimental protocols
30. Lamp colour properties and apparent brightness: A review10.1177/136578280103300306 ↗
31. Practical use and calculation of CCT and Duv
32. Effects of correlated color temperature on spatial brightness perception10.1002/col.20711 ↗
33. Brightness perception of white LED lights with different correlated colour temperatures10.1177/1420326X14528732 ↗
34. Preferred chromaticity of color-tunable LED lighting
35. Spatial brightness perception of trichromatic stimuli
36. KSA (1998). KSA 3011-2018-Recommended Levels of Illumination, KSA.
37. Influence of wall luminance and uniformity on preferred task illuminance10.1016/j.buildenv.2017.02.026 ↗
38. Dimming strategies for open office lighting: User experience and acceptance10.1177/1477153518772154 ↗
39. Human perceptions of colour rendition at different chromaticities10.1177/1477153517725974 ↗
40. Human perceptions of colour rendition vary with average fidelity, average gamut, and gamut shape10.1177/1477153516663615 ↗
41. Models of colour quality over a wide range of spectral power distributions10.1177/1477153518765953 ↗
42. NEMA (2015). C78.377-2015-American National Standard for Electric Lamps—Specifications for the Chromaticity of Solid State Lighting (SSL) Products, NEMA.
43. Analysis of occupants’ visual perception to refine indoor lighting environment for office tasks10.3390/en7074116 ↗
44. Lighting for work: A study of the relationships among discomfort glare, physiological responses and visual performance10.1016/j.buildenv.2019.106478 ↗
45. Psychological consideration of legibility on the typeface and line spacing
46. The effect of hangul font on reading speed in the computer environment10.5143/JESK.2013.32.5.449 ↗
47. Field study of office worker responses to fluorescent lighting of different CCT and lumen output10.1016/j.jenvp.2014.04.009 ↗
48. Lighting quality and energy-efficiency effects on task performance, mood, health, satisfaction, and comfort10.1080/00994480.1998.10748216 ↗
49. Wang, M.L., and Luo, M.R. (2016, January 15–17). Effects of LED lighting on office work performance. Proceedings of the 2016 13th China International Forum on Solid State Lighting, Beijing, China.10.1109/SSLCHINA.2016.7804366 ↗
50. The effect of high correlated colour temperature office lighting on employee wellbeing and work performance10.1186/1740-3391-5-2 ↗