A Validation Method for EPID In Vivo Dosimetry Algorithms
Source abstract
Abstract
The aim of this study was to develop and apply an evaluation method for assessing the accuracy of a novel 3D EPID back-projection algorithm for in vivo dosimetry. The novel algorithm of Dosimetry Check (DC) 5.8 was evaluated. A slab phantom homogeneously filled, or with air and bone inserts, was used for fluence reconstruction of different squared fields. VMAT plans in different anatomical sites were delivered on an anthropomorphic phantom. Dose distributions were measured with radiochromic films. The 2D Gamma Agreement Index (GAI) between the DC and the film dose distributions (3%, 3 mm) was computed for assessing the accuracy of the algorithm. GAIs between films and TPS and between DC and TPS were also computed. The fluence reconstruction accuracy was within 2% for all squared fields in the three slabs’ configurations. The GAI between the DC and the film was 92.7% in the prostate, 92.9% in the lung, 96.6% in the head and the neck, and 94.6% in the brain. An evaluation method for assessing the accuracy of a novel EPID algorithm was developed. The DC algorithm was shown to be able to accurately reconstruct doses in all anatomic sites, including the lung. The methodology described in the present study can be applied to any EPID back-projection in vivo algorithm.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Radiotherapy Techniques · Radiation Dose and Imaging · Radiation Therapy and Dosimetry
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Medical Physics Unit, Azienda USL Toscana Centro, 50100 Florence, Italy
Medical Physics Unit, Careggi University Hospital, 50100 Florence, Italy
Medical Physics Unit, Azienda Ospedaliera Universitaria Senese, 53100 Siena, Italy
Department of Experimental and Clinical Biomedical Sciences “Mario Serio”, University of Florence, 50100 Florence, Italy
References (21)
Show source-provided references
1. International Atomic Energy Agency (2013). Development of Procedures for In Vivo Dosimetry in Radiotherapy, IAEA. IAEA Human Health Report No. 8.
2. (2021, November 05). COUNCIL DIRECTIVE 2013/59/EURATOM of 5 December 2013. Available online: https://eur-lex.europa.eu/eli/dir/2013/59/oj.
3. Estimating dose delivery accuracy in stereotactic body radiation therapy: A review of in-vivo measurement methods10.1016/j.radonc.2020.05.014 ↗
4. Characterization of EPID software for VMAT transit dosimetry10.1007/s13246-018-0693-0 ↗
5. Arilli, C., Wandael, Y., Galeotti, C., Marrazzo, L., Calusi, S., Grusio, M., Desideri, I., Fusi, F., Piermattei, A., and Pallotta, S. (2020). Combined Use of a Transmission Detector and an EPID-Based In Vivo Dose Monitoring System in External Beam Whole Breast Irradiation: A Study with an Anthropomorphic Female Phantom. Appl. Sci., 10.10.3390/app10217611 ↗
6. Clinical implementation of 3D in vivo dosimetry for abdominal and pelvic stereotactic treatments10.1016/j.radonc.2020.09.011 ↗
7. Evaluation of automated pre-treatment and transit in-vivo dosimetry in radiotherapy using empirically determined parameters10.1016/j.phro.2020.09.011 ↗
8. (2010). ICRU: Prescribing, Recording, and Reporting Photon-Beam Intensity-Modulated Radiation Therapy (IMRT), Oxford University Press. ICRU Report 83, J. ICRU.
9. Improving dose delivery accuracy with EPID in vivo dosimetry: Results from a multicenter study10.1007/s00066-021-01749-6 ↗
10. Overview of 3-year experience with large-scale electronic portal imaging device–based 3-dimensional transit dosimetry10.1016/j.prro.2015.07.001 ↗
11. Clinical implementation and rapid commissioning of an EPID basedin-vivodosimetry system10.1088/0031-9155/59/19/N171 ↗
12. Transit and non-transit 3D EPID dosimetry versus detector arrays for patient specific QA10.1002/acm2.12610 ↗
13. EPID-based 3D dosimetry for pre-treatment FFF VMAT stereotactic body radiotherapy plan verification using dosimetry CheckTM10.1016/j.ejmp.2020.12.014 ↗
14. In vivo dosimetry in external beam photon radiotherapy: Requirements and future directions for research, development, and clinical practice10.1016/j.phro.2020.08.003 ↗
15. Dose-calculation algorithms in the context of inhomogeneity corrections for high energy photon beams10.1118/1.3213523 ↗
16. GafChromic® EBT3 films for patient specific IMRT QA using a multichannel approach10.1016/j.ejmp.2015.08.010 ↗
17. In aqua vivo EPID dosimetry10.1118/1.3665709 ↗
18. Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method10.1118/1.2147744 ↗
19. Validation of a method for in vivo 3D dose reconstruction for IMRT and VMAT treatments using on-treatment EPID images and a model-based forward-calculation algorithm10.1118/1.4935199 ↗
20. Multichannel film dosimetry with nonuniformity correction10.1118/1.3576105 ↗
21. An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan10.1118/1.4754797 ↗