Design, Modeling, and Analysis of Piezoelectric-Actuated Device for Blood Sampling
Source abstract
Abstract
In recent years, micro electro-mechanical system (MEMS)-based biomedical devices have been investigated by various researchers for biomedicine, disease diagnosis, and liquid drug delivery. The micropump based devices are of considerable significance for accurate drug delivery and disease diagnosis. In the present study, design aspects of the piezoelectric actuated micropump used for extraction of blood sample are presented. A pentagonal microneedle, which is an integral part of the micropump, was used to extract the blood volume. The blood was then delivered to the biosensor, located in the pump chamber, for diagnosis. The purpose of such low-powered devices is to get sufficient blood volume for the diagnostic purpose at the biosensor located within the pump chamber, with a minimum time of actuation, which will eventually cause less pain. ANSYS® simulations were performed on four quarter piezoelectric bimorph actuator (FQPB) at 2.5 volts. The modal and harmonic analysis were carried out with various load conditions for FQPB. The extended microneedle lengths inside the pump chamber showed improved flow characteristics. Enhanced volume flow rate of 1.256 µL/s was obtained at 22,000 Hz applied frequency at the biosensor location.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Microfluidic and Capillary Electrophoresis Applications · Microfluidic and Bio-sensing Technologies · Innovative Microfluidic and Catalytic Techniques Innovation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
I. I. Vorovich Mathematics, Mechanics and Computer Sciences Institute, Southern Federal University, 344090 Rostov-on-Don, Russia
Mechanical Engineering Discipline, PDPM Indian Institute of Information Technology, Design and Manufacturing, Jabalpur 482005, India
Funding
Ministry of Science and Higher Education of the Russian Federation
References (34)
Show source-provided references
1. Atlas, I.D.F.D. (2019). IDF Diabetes Atlas Ninth Edition, International Diabetes Federation. [9th ed.].
2. A review of recent studies on piezoelectric pumps and their applications10.1016/j.ymssp.2020.107393 ↗
3. Asadi Dereshgi, H., Dal, H., and Yildiz, M.Z. (2021). Piezoelectric micropumps: State of the art review. Microsyst. Technol., 1–29.10.1007/s00542-020-05190-0 ↗
4. A review of micropumps10.1088/0960-1317/14/6/R01 ↗
5. Three-dimensional electro-fluid–structural interaction simulation for pumping performance evaluation of a valveless micropump10.1088/0964-1726/18/10/104015 ↗
6. Simulation of a piezoelectrically actuated valveless micropump10.1088/0964-1726/14/2/014 ↗
7. Design and test of a high-performance piezoelectric micropump for drug delivery10.1016/j.sna.2004.12.002 ↗
8. Electronmc Mosquito: Designing a semi-invasive microsystem for blood sampling, analysis and drug delivery applications10.1007/s00542-005-0015-9 ↗
9. Development of blood extraction system for health monitoring system10.1007/s10544-005-6077-8 ↗
10. Simulations and analysis of a piezoelectric micropump10.1016/j.ultras.2006.05.018 ↗
11. Four segment piezo based micropump10.1117/12.2265631 ↗
12. Yazdi, S.A.F.F., Corigliano, A., and Ardito, R. (2019). 3-D design and simulation of a piezoelectric micropump. Micromachines, 10.10.3390/mi10040259 ↗
13. Simulation and optimization of a piezoelectric micropump for medical applications10.1007/s00170-006-0867-x ↗
14. The Effect of Operating Frequency and Needle Diameter on Performance of Piezoelectric Micropump10.1007/978-3-319-78919-4_44 ↗
15. Aboubakri, A., and Ahmadi, V.E. (2020). Modeling of a Passive-Valve Piezoelectric Micro-Pump: A Parametric Study. Micromachines, 11.10.3390/mi11080752 ↗
16. A metallic micropump for high-pressure microfluidics10.1088/0960-1317/18/11/115009 ↗
17. Multifield analysis of a piezoelectric valveless micropump: Effects of actuation frequency and electric potential10.1088/0964-1726/21/7/075002 ↗
18. New piezoelectric actuator design for enhance the micropump flow10.1016/j.matpr.2020.10.702 ↗
19. A dynamic piezoelectric micropumping phenomenon10.1007/s10404-009-0556-9 ↗
20. Peristaltic piezoelectric micropump system for biomedical applications10.1007/s10544-007-9075-1 ↗
21. Current micropump technologies and their biomedical applications10.1007/s00542-009-0804-7 ↗
22. Design and analysis of MEMS based piezoelectric micro pump integrated with micro needle
23. Kimoto, H., Inoue, T., Tsuchiya, K., Kajiwara, K., and Kimura, M. (2014, January 10–12). Selection of the best shape for a micro painless needle. Proceedings of the 2014 International Symposium on Micro-NanoMechatronics and Human Science (MHS), Nagoya, Japan.10.1109/MHS.2014.7006106 ↗
24. Modeling and flow analysis of piezoelectric based micropump with various shapes of microneedle10.1007/s12206-017-0536-z ↗
25. CFD Analysis of Pulsatile Flow and Non-Newtonian Behavior of Blood in Arteries CFD Analysis of Pulsatile Flow and Non-Newtonian Behavior of Blood in Arteries
26. An optimized hollow microneedle for minimally invasive blood extraction10.1007/s10544-012-9683-2 ↗
27. A robust enzymeless glucose sensor based on CuO nanoseed modified electrodes10.1039/C5DT01664A ↗
28. Sandhyarani, N. (2019). Surface modification methods for electrochemical biosensors. Electrochem. Biosens., 45–75.10.1016/B978-0-12-816491-4.00003-6 ↗
29. The Piezoelectric Capillary Injector—A New Hydrodynamic Method for Dot Pattern Generation10.1109/T-ED.1973.17603 ↗
30. Computational and experimental characterization of a low-cost piezoelectric valveless diaphragm pump10.1177/1045389X11429172 ↗
31. Simulation of Piezoelectric Devices by Two- and Three-Dimensional Finite Elements10.1109/58.55314 ↗
32. Effects of the non-Newtonian viscosity of blood on flows in a diseased arterial vessel. Part 1: Steady flows10.3233/BIR-1991-283-415 ↗
33. Non-Newtonian Blood Flow in Left Coronary Arteries with Varying Stenosis: A Comparative Study
34. Evaluation of the effects of insufficient blood volume samples on the performance of blood glucose self-test meters10.1177/193229681300700612 ↗