Axial Compression Performance and Residual Strength Calculation of Concrete-Encased CFST Composite Columns Exposure to High Temperature
Source abstract
Abstract
Concrete-encased concrete-filled steel tube (CFST) composite columns provide high bearing capacity, good seismic performance and an easier connection with arbitrary angle beams, which are widely used in high-rise buildings. Considering the high frequency of building fires, experimental research investigated the axial compressive behavior of the composite columns’ exposure to high temperature in this paper. Fourteen specimens after exposure to high temperatures with different parameters, including the heating temperature, steel tube diameter and concrete cover thickness, were fabricated to test under axial compressive loading. The failure pattern, load-displacement curve, bearing capacity, initial stiffness, deformation performance and damage rule of the specimens were discussed. The test results showed obvious differences in damage of specimens subjected to various high temperatures. The failure of the specimens began with the spalling and crushing of the concrete at the edge and ends in a lantern shape. The load-displacement curves of the specimens were significantly affected by high temperature, while the influence the of steel tube diameter and concrete cover thickness was relatively weak. A method of calculating axially loaded capacity for the composite column exposure to high temperature is proposed considering the effects of the main parameters of heating temperature and steel tube position, and the calculated results are in good agreement with the experimental results.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Fire effects on concrete materials · Structural Load-Bearing Analysis · Structural Behavior of Reinforced Concrete
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Civil Engineering and Architecture, Guangxi University, Nanning 530004, China
Key Laboratory of Disaster Prevention and Structural Safety of Ministry of Education, Guangxi University, Nanning 530004, China
Funding
National Natural Science Foundation of China · Natural Science Foundation of Guangxi Province
References (35)
Show source-provided references
1. Numerical analysis of high-strength concrete-filled steel tubular slender beam-columns under cyclic loading10.1016/j.jcsr.2013.09.008 ↗
2. Gong, Y., Ding, F., Wang, L., Huang, B., Shan, Y., and Lyu, F. (2021). Finite model analysis and practical design equations of circular concrete-filled steel tube columns subjected to compression-torsion load. Materials, 14.10.3390/ma14195564 ↗
3. Wang, G., Bao, Y., Yang, L., and Yu, Y. (2021). Analysis of fire resistance of square-cased square steel tube reinforced concrete (st-rc) columns. Materials, 14.10.3390/ma14195541 ↗
4. Analytical modeling of the standard fire behavior of loaded CFT columns10.1016/j.jcsr.2008.04.008 ↗
5. Post-fire bond between the steel tube and concrete in concrete-filled steel tubular columns10.1016/j.jcsr.2010.09.006 ↗
6. Fire behaviour of eccentrically loaded slender high strength concrete-filled tubular columns10.1016/j.jcsr.2013.01.011 ↗
7. Numerical study on temperature distribution of high-strength concrete-filled steel tubes subjected to a fire10.1007/s13296-016-0021-z ↗
8. Fire performance of concrete filled steel tubular beam-columns10.1016/S0143-974X(00)00030-4 ↗
9. Fire behaviour of concrete filled elliptical steel columns10.1016/j.tws.2010.10.008 ↗
10. Circular and square slender concrete-filled tubular columns under large eccentricities and fire10.1016/j.jcsr.2015.03.011 ↗
11. Fire performance of innovative steel-concrete composite columns using high strength steels10.1016/j.tws.2016.04.014 ↗
12. Fire behaviour of high strength self-consolidating concrete filled steel tubular stub columns10.1016/j.jcsr.2009.06.013 ↗
13. Performance of CFST column to steel beam joints subjected to simulated fire including cooling phase10.1016/j.jcsr.2009.12.006 ↗
14. Ding, F., Liao, C., Wang, E., Lyu, F., Xu, Y., Liu, Y., Feng, Y., and Shang, Z. (2021). Numerical investigation of the composite action of axially compressed concrete-filled circular aluminum alloy tubular stub columns. Materials, 14.10.3390/ma14092435 ↗
15. Behaviour of repaired concrete filled steel tubular column to steel beam joints after exposure to fire10.1260/1369-4332.13.1.53 ↗
16. Zhou, C., Chen, W., Ruan, X., and Tang, X. (2019). Experimental study on axial compression behavior and bearing capacity analysis of high titanium slag cfst columns. Appl. Sci., 9.10.3390/app9102021 ↗
17. Experimental study of structural fire behaviour of steel beam to concrete filled tubular column assemblies with different types of joints10.1016/j.engstruct.2007.08.018 ↗
18. Experimental behaviour of reinforced concrete (RC) beam to concrete-filled steel tubular (CFST) column frames subjected to ISO-834 standard fire10.1016/j.engstruct.2010.06.001 ↗
19. Fire resistance behavior and mechanism of concrete filled square hollow columns in non-uniform fires
20. Axial compressive performance of RAC-encased RACFST composite columns10.1016/j.engstruct.2020.110393 ↗
21. Effect of cumulative seismic damage to steel tube-reinforced concrete composite columns10.12989/eas.2014.7.2.179 ↗
22. Behavior of ECC-encased CFST columns under axial compression10.1016/j.engstruct.2018.05.090 ↗
23. Experimental study on the hysteretic behavior of ECC-encased CFST columns10.1016/j.engstruct.2018.06.095 ↗
24. Behaviour of concrete-encased CFST columns under combined compression and bending10.1016/j.jcsr.2014.06.002 ↗
25. Behavior of concrete-encased CFST members under axial tension10.1061/(ASCE)ST.1943-541X.0001422 ↗
26. Behaviour of composite joints with concrete encased CFST columns under cyclic loading: Experiments10.1016/j.engstruct.2013.11.030 ↗
27. Seismic behavior and strength capacity of steel tube- reinforced concrete composite columns10.1002/eqe.2354 ↗
28. Concrete filled steel tube reinforced concrete (cfstrc) columns subjected to ISO-834 standard fire: Experiment10.1260/1369-4332.16.7.1263 ↗
29. Numerical analysis on structural behaviors of concrete filled steel tube reinforced concrete (CFSTRC) columns subjected to 3-side fire10.1007/s13296-017-1219-4 ↗
30. Numerical analysis on mechanical property of concrete filled steel tube reinforced concrete (CFSTRC) columns subjected to ISO-834 standard fire10.1007/s13296-017-1223-8 ↗
31. (2003). Standard for Test Method of Mechanical Properties on Ordinary Concrete. Standard No. GB/T 50081-2002. (In Chinese).
32. (2010). Metallic Materials Tensile Testing at Ambient Temperature. Standard No. GB/T 228.1-2010. (In Chinese).
33. (2005). Technical Specification for Steel Tube-Reinforced Concrete Column Structure. Standard No. CECS 188:2005. (In Chinese).
34. (2010). Code for Design of Concrete Structures. Standard No. GB 50010-2010. (In Chinese).
35. Comite Eur0-International du Beton (1993). Bulletion D’information No.213/214 CEB-FIP Model Code 1990 (Concrete Structures), Comite Eur0-International du Beton.