journal article·2021-04-25Open access

Development of Shear Resistance Formula for the Y-Type Perfobond Rib Shear Connector Considering Probabilistic Characteristics

Sang-Hyo Kim, Tuvshintur Batbold, Syed Haider Ali Shah, Suro Yoon, Oneil Han

Applied Sciences· Volume 11· Issue 9

Abstract

A design shear resistance formula for Y-type perfobond rib shear connectors is proposed with the various reduction factors, which can be selected depending on the target safety level. The nominal shear resistance formula is improved based on the systematic sensitivity analysis as well as the regression fit test based on 84 push-out test results, including 15 additional push-out tests to extend the application ranges and reduce the estimation errors, compared to the formula proposed in previous studies. Some design variables are additionally included in the proposed design formula: the yield strengths of rebar and rib plate. The basic design variables in the proposed design formula are (1) number of ribs and transverse rebars, (2) concrete compressive strength, (3) rebar diameter and yield strength, and (4) rib thickness, width, height, and yield strength. The application ranges of the basic design variables are recommended for the proposed design formula. The various shear resistance reduction factors are proposed based on the probabilistic ultimate shear resistance model of Y-type perfobond rib shear connectors. The proposed procedure may be recommended to develop the design formula for shear connectors with various shapes.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Structural Load-Bearing Analysis · Structural Behavior of Reinforced Concrete · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Civil and Environmental Engineering, Yonsei University, Seoul 03600, Korea

Funding

Korea Institute of Energy Technology Evaluation and Planning (KETEP) and the Ministry of Trade, Industry & Energy (MOTIE) of the Republic of Korea

References (25)

Show source-provided references
1. Static behavior of large stud shear connectors in steel-UHPC composite structures10.1016/j.engstruct.2018.07.058 ↗
2. Comparative performance of channel and angle shear connectors in high strength concrete composites: An experimental study10.1016/j.conbuildmat.2016.05.102 ↗
3. Experimental study of the short-term and long-term behavior of perfobond connectors10.1016/j.jcsr.2018.09.004 ↗
4. Experimental shear resistance evaluation of Y-type perfobond rib shear connector10.1016/j.jcsr.2012.12.001 ↗
5. Hechler, O., Berthellemy, J., Lorenc, W., Seidl, G., and Viefhues, E. (2011). Continuous shear Connectors in bridge Construction. Composite Construction Steel Concrete VI, ASCE.10.1061/41142(396)7 ↗
6. Shear strength of stud connectors in lightweight and normal weight concrete10.62913/engj.v8i2.160 ↗
7. Behavior of stud connections between concrete slabs and steel girders under transverse bending moment10.1016/j.engstruct.2016.03.014 ↗
8. Static behavior and theoretical model of stud shear connectors10.1061/(ASCE)1084-0702(2008)13:6(623) ↗
9. Static behavior of stud shear connectors in high-strength-steel–UHPC composite beams10.1016/j.engstruct.2020.110827 ↗
10. A parametric study of perfobond rib shear connectors10.1139/l94-063 ↗
11. Shear resistance of the perfobond-rib shear connector depending on concrete strength and rib arrangement10.1016/j.jcsr.2010.04.008 ↗
12. Experimental evaluation of the structural response of Perfobond shear connectors10.1016/j.engstruct.2010.02.031 ↗
13. Shear behavior and analytical model of perfobond connectors10.12989/scs.2016.20.1.071 ↗
14. Yoshitaka, U., Tetsuya, H., and Kaoru, M. (2001). An Experimental Study on Shear Characteristics of Perfobond Strip and its Rational Strength Equations. International Symposium on Connections Between Steel and Concrete, RILEM Publications SARL.
15. Push-out tests for perfobond strip connectors with UHPC grout in the joints of steel-concrete hybrid bridge girders10.1016/j.engstruct.2017.01.008 ↗
16. Composite dowels as shear connectors for composite beams—Background to the design concept for static loading10.1016/j.jcsr.2018.04.013 ↗
17. Generalized formulation for shear resistance on Y-type perfobond rib shear connectors10.1016/j.jcsr.2016.08.016 ↗
18. Shear resistance characteristic and ductility of Y-type perfobond rib shear connector10.12989/scs.2015.18.2.497 ↗
19. End-bearing resistance of Y-type perfobond rib according to rib width–height ratio10.1016/j.jcsr.2014.08.003 ↗
20. Experimental behavior of double-row Y-type perfobond rib shear connectors10.1016/j.jcsr.2018.08.012 ↗
21. Influence of transverse rebar on shear behavior of Y-type perfobond rib shear connection10.1016/j.conbuildmat.2018.06.002 ↗
22. Kang, G.Y. (2018). Shear Resistance of Y-Type Perfobond Rib Shear Connectors According to Steel Grade and Transverse Rebar Grade. [Master’s Thesis, Yonsei University].
23. (2004). Eurocode 4–1994, Design of Composite Steel and Concrete Structures, Part 1.1: General Rules and Rules for Buildings, EN1994-1-1, European Committee for Standardization.
24. (2018). Korean Standard D3503 Rolled Steels for General Structure, Korean Agency for Technology and Standards.
25. Calibration of design code for buildings (ACI 318): Part 1-Statistical models for resistance