sEMG Signals Characterization and Identification of Hand Movements by Machine Learning Considering Sex Differences
Source abstract
Abstract
Developing a robust machine-learning algorithm to detect hand motion is one of the most challenging aspects of prosthetic hands and exoskeleton design. Machine-learning methods that considered sex differences were used to identify and describe hand movement patterns in healthy individuals. To this purpose, surface Electromyographic (sEMG) signals have been acquired from muscles in the forearm and hand. The results of statistical analysis indicated that most of the same muscle pairs in the right hand (females and males) showed significant differences during the six hand movements. Time features were used an as input to machine-learning algorithms for the recognition of six gestures. Specifically, two types of hand-gesture recognition methods that considered sex differences(differentiating sex datasets and adding a sex label)were proposed and applied to the k-nearest neighbor (k-NN), support vector machine (SVM) and artificial neural network (ANN) algorithms for comparison. In addition, a t-test statistical analysis approach and 5-fold cross validation were used as complements to verify whether considering sex differences could significantly improve classification performance. It was demonstrated that considering sex differences can significantly improve classification performance. The ANN algorithm with the addition of a sex label performed best in movement classification (98.4% accuracy). In the future, hand movement recognition algorithms considering sex differences could be applied to control systems for prosthetic hands or exoskeletons.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Muscle activation and electromyography studies · Stroke Rehabilitation and Recovery · EEG and Brain-Computer Interfaces
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan 030024, China
Funding
National Natural Science Foundation of China
References (44)
Show source-provided references
1. An Analysis of Intrinsic and Extrinsic Hand Muscle EMG for Improved Pattern Recognition Control10.1109/TNSRE.2015.2424371 ↗
2. Limb amputation and limb deficiency: Epidemiology and recent trends in the United States
3. Estimating the prevalence of limb loss in the United States: 2005 to 205010.1016/j.apmr.2007.11.005 ↗
4. Waryck, B. (2011). Comparison Of Two Myoelectric Multi-Articulating Prosthetic Hands. Myoelectric Symp.
5. Global Stroke Statistics 201910.1177/1747493020909545 ↗
6. Heart Disease and Stroke Statistics-2018 Update A Report From the American Heart Association10.1161/CIR.0000000000000558 ↗
7. Estimates of the prevalence of acute stroke impairments and disability in a multiethnic population10.1161/01.STR.32.6.1279 ↗
8. Alterations in muscle activation patterns during robotic-assisted walking10.1016/j.clinbiomech.2004.09.016 ↗
9. Effects of robot-assisted therapy on upper limb recovery after stroke: A systematic review10.1177/1545968307305457 ↗
10. Lambercy, O., Lünenburger, L., and Gassert, R. (2012). Robots for Measurement/Clinical Assessment. Neurorehabilitation Technology, Springer.10.1007/978-1-4471-2277-7_24 ↗
11. Robot-assisted Therapy in Stroke Rehabilitation10.5853/jos.2013.15.3.174 ↗
12. Robot-assisted rehabilitation of hand function
13. An overall framework for neurorehabilitation robotics: Implications for recovery
14. Takahashi, C.D., Der-Yeghiaian, L., Le, V.H., and Cramer, S.C. (July, January 28). A robotic device for hand motor therapy after stroke. Proceedings of the 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005, Chicago, IL, USA.
15. A Haptic Knob for Rehabilitation of Hand Function10.1109/TNSRE.2007.903913 ↗
16. Ho, N.S.K., Tong, K.Y., Hu, X.L., Fung, K.L., Wei, X.J., Rong, W., and Susanto, E.A. (July, January 29). An EMG-driven exoskeleton hand robotic training device on chronic stroke subjects: Task training system for stroke rehabilitation. Proceedings of the IEEE International Conference on Rehabilitation Robotics, Zurich, Switzerland.
17. Development and pilot testing of HEXORR: Hand EXOskeleton Rehabilitation Robot10.1186/1743-0003-7-36 ↗
18. Polygerinos, P., Galloway, K.C., Sanan, S., Herman, M., and Walsh, C.J. (2015, January 11–14). EMG controlled soft robotic glove for assistance during activities of daily living. Proceedings of the IEEE International Conference on Rehabilitation Robotics, Singapore.10.1109/ICORR.2015.7281175 ↗
19. Gloreha-Hand Robotic Rehabilitation: Design, Mechanical Model, and Experiments10.1115/1.4033831 ↗
20. Design and Development of a Portable Exoskeleton for Hand Rehabilitation10.1109/TNSRE.2018.2878778 ↗
21. EMG-driven hand model based on the classification of individual finger movements10.1016/j.bspc.2019.101834 ↗
22. Intention-Based EMG Control for Powered Exoskeletons10.1109/TBME.2012.2198821 ↗
23. EMG-Based Neural Network Control of Transhumeral Prostheses10.1682/JRRD.2010.12.0237 ↗
24. Control of Upper Limb Prostheses: Terminology and Proportional Myoelectric Control—A Review10.1109/TNSRE.2012.2196711 ↗
25. A Variance Distribution Model of Surface EMG Signals Based on Inverse Gamma Distribution10.1109/TBME.2017.2657121 ↗
26. Feature reduction and selection for EMG signal classification10.1016/j.eswa.2012.01.102 ↗
27. Transradial Amputee Gesture Classification Using an Optimal Number of sEMG Sensors: An Approach Using ICA Clustering10.1109/TNSRE.2015.2478138 ↗
28. A new strategy for multifunction myoelectric control10.1109/10.204774 ↗
29. Portable hand motion classifier for multi-channel surface electromyography recognition using grey relational analysis10.1016/j.eswa.2009.11.072 ↗
30. Robinson, C.P., Li, B., Meng, Q., and Pain, M.T.G. (2015, January 14–17). Pattern Classification of Hand Movements using Time Domain Features of Electromyography. Proceedings of the 4th International Conference on Movement and Computing, New York, NY, USA.
31. Classification of Finger Movements for the Dexterous Hand Prosthesis Control With Surface Electromyography10.1109/JBHI.2013.2249590 ↗
32. Support vector machine-based classification scheme for myoelectric control applied to upper limb10.1109/TBME.2008.919734 ↗
33. Ariyanto, M., Caesarendra, W., Mustaqim, K.A., Irfan, M., Pakpahan, J.A., Setiawan, J.D., and Winoto, A.R. (2015, January 29–30). Finger Movement Pattern Recognition Method Using Artificial Neural Network Based on Electromyography (EMG) Sensor. Proceedings of the 2015 International Conference on Automation, Cognitive Science, Optics, Micro Electro-Mechanical System, and Information Technology, Bandung, Indonesia.10.1109/ICACOMIT.2015.7440146 ↗
34. Sex differences in upper limb 3D joint contributions during a lifting task10.1080/00140139.2019.1571245 ↗
35. Sex differences in glenohumeral muscle activation and coactivation during a box lifting task10.1080/00140139.2019.1640396 ↗
36. Fatigability of the elbow flexor muscles for a sustained submaximal contraction is similar in men and women matched for strength10.1152/japplphysiol.00893.2003 ↗
37. Human skeletal muscle responses vary with age and gender during fatigue due to incremental isometric exercise10.1152/japplphysiol.00091.2002 ↗
38. Gender difference in hand grip strength and electromyogram (EMG) changes in upper limb
39. Differences in Muscle Oxygenation Level According to Gender during Isometric Hand-grip Exercises
40. Zeng, H.B., Li, K., Tian, X.C., Wei, N., Song, R., and Zhou, L.L. (2017, January 20–22). Classification of hand motions using linear discriminant analysis and support vector machine. Proceedings of the 2017 Chinese Automation Congress (CAC), Jinan, China.10.1109/CAC.2017.8243169 ↗
41. Du, S.J., and Vuskovic, M. (2021, January 8–10). Temporal vs. spectral approach to feature extraction from prehensile EMG signals. Proceedings of IEEE International Conference on Information Reuse and Integration, Las Vegas, NV, USA.
42. Zhang, D.H., Xiong, A.B., Zhao, X.G., and Han, J.D. (2012, January 6–8). PCA and LDA for EMG-based Control of Bionic Mechanical hand. Proceedings of IEEE International Conference on Information and Automation (ICIA), Shenyang, China.10.1109/ICInfA.2012.6246955 ↗
43. Application of real-time machine learning to myoelectric prosthesis control: A case series in adaptive switching10.1177/0309364615605373 ↗
44. Pilarski, P.M., Dawson, M.R., Degris, T., Carey, J.P., and Sutton, R.S. (2012, January 24–27). Dynamic switching and real-time machine learning for improved human control of assistive biomedical robots. Proceedings of the 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob), Rome, Italy.10.1109/BioRob.2012.6290309 ↗