journal article·2019-11-29Open access

Optimization of the Orifice Shape of Cooling Fan Units for High Flow Rate and Low-Level Noise in Outdoor Air Conditioning Units

Se Min Park, Seo-Yoon Ryu, Cheolung Cheong, Jong Wook Kim, Byung Il Park, Young-Chull Ahn, Sai Kee Oh

Applied Sciences· Volume 9· Issue 23

Abstract

Demand for air conditioners is steadily increasing due to global warming and improved living standards. The noise, as well as the performance of air conditioners, are recognized as one of the crucial factors that determine the air conditioners’ values. The performance and noise of the air conditioner are mostly determined by those of its outdoor unit, which in turn depend on those of the cooling fan unit. Therefore, a cooling fan unit of high-performance and low noise is essential for air-conditioner manufacturers and developers. In this paper, the flow performance and flow noise of the entire outdoor unit with an axial cooling fan in a split-type air-conditioner were investigated. First, a virtual fan tester constructed by using about 18 million grids is developed for highly resolved flow simulation. The unsteady Reynolds-Averaged Navier–Stokes equations are numerically solved by using finite-volume computational fluid dynamics techniques. To verify the validity of the numerical analysis, the predicted P–Q curve of the cooling fan in a full outdoor unit is compared with the measured one. There was an excellent agreement between the two curves. The further detailed analysis identifies the coherent vortex structures between the fan blade tip and fan orifice, which adversely affect the flow performance and causes flow noise. Based on this analysis, the optimization of fan orifice was carried out using the response surface method with three geometric parameters: inlet radius, neck length, and outlet angel of the orifice. The optimum layout for the high flow rate is proposed under the understanding that the increased flow rate can be converted to noise reduction. The additional computation using the proposed optimum orifice shows that the flow rate is increased by 4.6% at the operating point. Finally, the engineering sample was manufactured by using the optimum design, and the measured data confirmed that the flow rate were increased by 2.1%, the noise reduction was made by 2.8 dBA, and the power consumption is reduced by 4.0% at the operating rotational speed.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Aerodynamics and Acoustics in Jet Flows · Wind and Air Flow Studies · Heat Transfer Mechanisms

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

LG Electronics, Changwon 2nd Factory, Seonsan-dong, Changwon-city, Keongsang Namdo 51554, Korea

School of Mechanical Engineering, Pusan National University, Busan 46241, Korea

References (20)

Show source-provided references
1. Prediction and reduction of internal blade-passing frequency noise of the centrifugal fan in a refrigerator10.1016/j.ijrefrig.2010.03.006 ↗
2. Development of low-noise centrifugal fans for a refrigerator using inclined S-shaped trailing edge10.1016/j.ijrefrig.2011.07.003 ↗
3. Unsteady Fast Random Particle Mesh method for efficient prediction of tonal and broadband noises of a centrifugal fan unit10.1063/1.4930979 ↗
4. Development of high-performance and low-noise axial-flow fan units in their local operating region10.1007/s12206-015-0809-3 ↗
5. Prediction and measurement of axial flow fan aerodynamic and aeroacoustic performance in a split-type air-conditioner outdoor unit10.1016/j.ijrefrig.2012.11.024 ↗
6. Experimental and numerical study on aeroacoustic sound of axial flow fan in room air conditioner10.1016/j.apacoust.2005.12.011 ↗
7. Wright, T., and Simmons, W.E. (1989). Blade sweep for low-speed axial fans. ASME 1989 International Gas Turbine and Aeroengine Congress and Exposition, American Society of Mechanical Engineers.10.1115/89-GT-53 ↗
8. Numerical investigation of blade tip grooving effect on performance and dynamics of an axial flow fan10.1016/j.energy.2015.01.065 ↗
9. Aerodynamic performance improvement of up-flow outdoor unit of air conditioner by redesigning the bell-mouth profile10.1016/j.ijrefrig.2014.08.015 ↗
10. Effect of deflecting ring on noise generated by outdoor set of a split-unit air conditioner10.1016/j.ijrefrig.2005.07.002 ↗
11. Investigation of air-flow fields and aeroacoustic noise in outdoor unit for split-type air conditioner10.3397/1.2888392 ↗
12. Korea Standards (2002). Room air-conditioners, KS C 9306, Korean Standards Association.
13. Comparison of turbulence models in simulating swirling pipe flows10.1016/j.apm.2009.12.018 ↗
14. Effect of different turbulence models on combustion and emission characteristics of hydrogen/air flames10.1016/j.ijhydene.2017.04.080 ↗
15. Renormalization group analysis of turbulence. I. Basic theory10.1007/BF01061452 ↗
16. Assessment study of K-ɛ turbulence models and near-wall modeling for steady state swirling flow analysis in draft tube using fluent
17. Sound Generation by Turbulence and Surfaces in Arbitrary Motion
18. Response surface method-based optimization of the shroud of an axial cooling fan for high performance and low noise10.1007/s12206-012-1220-y ↗
19. Montgomery, D.C. (2005). Design and Analysis of Experiments, John Wiley and Sons. [6th ed.].
20. Khuri, A.I., and Cornell, J.A. (1996). Response Surfaces, Marcel Dekker. [2nd ed.].