Design of a Solar-Powered Portable ECG Device with Optimal Power Consumption and High Accuracy Measurement
Source abstract
Abstract
One of the best ways to monitor the health of the heart is to regularly record its electrical activity by using an electrocardiogram (ECG). Abnormal ECG signals may indicate conditions such as heart attack, arrhythmia, or heart defects. There are many ECG devices available which can detect and amplify this differential biological signal from the heart, allowing a lot of information to be collected quickly. The ECG is often small and easy to use, but its power is supplied from regular batteries, which need to be replaced after a certain period of use. This causes discomfort for elderly users. To overcome this limitation, in this paper, we aim to develop a solar-powered, portable Bluetooth device for ECG measurements. The device can be interfaced with smartphones or other wireless devices via Bluetooth by a distance up to 100 m. The ECG device was designed to use solar energy, which is also the main power source. Following the solar energy harvesting circuit is a solar panel with an output voltage of 2.4 V and a power out of 0.25 W. We optimized the design to have a very low power consumption and in sleep mode the current consumption is only around 40 µA. The device was designed with 24-bit resolution and a sampling frequency of up to 2133 Hz, which can allow high accuracy ECG measurements. The device is not only used for heart rate monitoring, but it can also assist doctors in analyzing ECG signals with a high accuracy via embedded operating software.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Energy Harvesting in Wireless Networks · Innovative Energy Harvesting Technologies · Wireless Body Area Networks
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Interdisciplinary Program of Biomedical Mechanical and Electrical Engineering, Pukyong National University, Busan 48513, Korea
College of Future Convergence, Pukyong National University, Busan 48513, Korea
Center for Marine-Integrated Biomedical Technology, Pukyong National University, Busan 48513, Korea
Department of Biomedical Engineering, Pukyong National University, Busan 48513, Korea
Funding
Ministry of Oceans and Fisheries
References (27)
Show source-provided references
1. American Heart Association (2018, January 31). Heart Disease and Stroke Statistics 2018 At-a-Glance. Available online: https://healthmetrics.heart.org/wp-content/uploads/2018/02/At-A-Glance-Heart-Disease-and-Stroke-Statistics-2018.pdf.
2. Wearable Noncontact Armband for Mobile ECG Monitoring System10.1109/TBCAS.2016.2519523 ↗
3. Gradl, S., Cibis, T., Lauber, J., Richer, R., Rybalko, R., Pfeiffer, N., Leutheuser, H., Wirth, M., von Tscharner, V., and Eskofier, B.M. (2017). Wearable Current-Based ECG Monitoring System with Non-Insulated Electrodes for Underwater Application. Appl. Sci., 7.10.3390/app7121277 ↗
4. Heartbeat classification using projected and dynamic features of ECG signal10.1016/j.bspc.2016.07.010 ↗
5. Problems in Assessment of Novel Biopotential Front-End with Dry Electrode: A Brief Review10.3390/machines2010087 ↗
6. Marco Longoni, D.C., Rossi, B., Fragneto, P., Pessione, M., and Boracchi, G. (2018, January 13–19). A Wearable Device for Online and Long-Term ECG Monitoring. Proceedings of the Twenty-Seventh International Joint Conference on Artificial Intelligence, Stockholm, Sweden.10.24963/ijcai.2018/855 ↗
7. Personal Medical Wearable Device for Distance Healthcare Monitoring X73-PHD
8. An efficient method for ECG beat classification and correction of ectopic beats10.1016/j.compeleceng.2015.12.015 ↗
9. Automatic atrial fibrillation and flutter detection by a handheld ECG recorder, and utility of sequential finger and precordial recordings10.1016/j.jelectrocard.2018.10.093 ↗
10. Cesarelli, P.B.G.R.F. (2007, January 26–30). Bluetooth Portable Device for ECG and Patient Motion Monitoring. Proceedings of the 11th Mediterranean Conference on Medical and Biomedical Engineering and Computing, Ljubljana, Slovenia.
11. Bhuvaneswari, P.T.V., Balakumar, R., Vaidehi, V., and Balamuralidhar, P. (2009, January 23–25). Solar Energy Harvesting for Wireless Sensor Networks. Proceedings of the 2009 First International Conference on Computational Intelligence, Communication Systems and Networks, Indore, India.10.1109/CICSYN.2009.91 ↗
12. Supercapacitor in battery charges of photovoltaic panel: Analysis of the technical feasibility10.1016/j.egypro.2018.10.019 ↗
13. An Adaptive System for Optimal Solar Energy Harvesting in Wireless Sensor Network Nodes10.1109/TCSI.2008.922023 ↗
14. A new dual-mode maximum power point tracking algorithm based on the Perturb and Observe algorithm used on solar energy system10.1016/j.solener.2018.09.013 ↗
15. A maximum power point tracking for photovoltaic systems based on Monod equation10.1016/j.renene.2018.06.017 ↗
16. Hybrid battery/supercapacitor energy storage system for the electric vehicles10.1016/j.jpowsour.2017.11.040 ↗
17. Texas Instruments (2014, December 17). ADS1293. Available online: http://www.ti.com/product/ADS1293?keyMatch=ads1293&tisearch=Search-EN-Everything.
18. MICROCHIP (2017, June 23). PIC16F19186. Available online: https://www.microchip.com/wwwproducts/en/PIC16F19186.
19. MICROCHIP (2015, September 18). RN4020. Available online: https://www.microchip.com/wwwproducts/en/RN4020.
20. Yuan, L., Yuan, Y., Zhou, Z., Bai, Y., and Wu, S. (2019). A Fetal ECG Monitoring System Based on the Android Smartphone. Sensors, 19.10.3390/s19030446 ↗
21. Monitoring of fetal heart rate using sharp transition FIR filter10.1016/j.bspc.2018.04.017 ↗
22. Singh, N., Ayub, S., and Saini, J.P. (2013, January 27–29). Design of Digital IIR Filter for Noise Reduction in ECG Signal. Proceedings of the 2013 5th International Conference and Computational Intelligence and Communication Networks, Mathura, India.10.1109/CICN.2013.45 ↗
23. Texas Instruments (2019, March 06). BQ25570. Available online: http://www.ti.com/product/BQ25570?keyMatch=bq25570&tisearch=Search-EN-Everything.
24. Biomedical Signal Processing and Control
25. Performance Study of Different Denoising Methods for ECG Signals10.1016/j.procs.2014.08.048 ↗
26. Denoising of ECG signals based on noise reduction algorithms in EMD and wavelet domains10.1016/j.bspc.2011.11.003 ↗
27. Sameni, R., Shamsollahi, M.B., Jutten, C., and Babaie-Zade, M. (2005). Filtering noisy ECG signals using the extended kalman filter based on a modified dynamic ECG model. Comput. Cardiol.10.1109/CIC.2005.1588283 ↗