New Implant Macrogeometry to Improve and Accelerate the Osseointegration: An In Vivo Experimental Study

Sergio Alexandre Gehrke, Jaime Aramburú Júnior, Leticia Pérez-Díaz, Tiago Luis Eirles Treichel, Berenice Anina Dedavid, Piedad N. De Aza, Juan Carlos Prados-Frutos

Applied Sciences· Volume 9· Issue 15

Abstract

A new implant design with healing chambers in the threads was analyzed and compared with a conventional implant macrogeometry, both implants models with and without surface treatment. Eighty conical implants were prepared using commercially pure titanium (grade IV) by the company Implacil De Bortoli (São Paulo, Brazil). Four groups were performed, as described below: Group 1 (G1), traditional conical implants with surface treatment; group 2 (G2), traditional conical implants without surface treatment (machined surface); group 3 (G3), new conical implant design with surface treatment; group 4 (G4), new conical implant design without surface treatment. The implants were placed in the two tibias (n = 2 implants per tibia) of twenty New Zealand rabbits determined by randomization. The animals were euthanized after 15 days (Time 1) and 30 days (Time 2). The parameters evaluated were the implant stability quotient (ISQ), removal torque values (RTv), and histomorphometric evaluation to determine the bone to implant contact (%BIC) and bone area fraction occupancy (BAFO%). The results showed that the implants with the macrogeometry modified with healing chambers in the threads produced a significant enhancement in the osseointegration, accelerating this process. The statistical analyses of ISQ and RTv showed a significative statistical difference between the groups in both time periods of evaluation (p ≤ 0.0001). Moreover, an important increase in the histological parameters were found for groups G3 and G4, with significant statistical differences to the BIC% (in the Time 1 p = 0.0406 and in the Time 2 p < 0.0001) and the BAFO% ((in the Time 1 p = 0.0002 and in the Time 2 p = 0.0045). In conclusion, the result data showed that the implants with the new macrogeometry, presenting the healing chambers in the threads, produced a significant enhancement in the osseointegration, accelerating the process.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Research, Biotecnos, Cuareim 1483, 11100 Montevideo, Uruguay

Department of Biotechnology, Universidad Católica de Murcia (UCAM), 30107 Murcia, Spain

Laboratorio de Interacciones Molecular, Facultad de Ciencias, Universidad de la Republica, Calle Iguá 4225, 11400 Montevideo, Uruguay

Department of Surgery, Faculty of Medicine Veterinary, University of Rio Verde, 75.901-970 Rio Verde, Brazil

Department of Materials Engineering, Pontificial Catholic University of Rio Grande do Sul, 90619-900 Porto Alegre, Brazil

Instituto de Bioingenieria, Universidad Miguel Hernández, Avda. Ferrocarril s/n. 03202- Elche, (Alicante), Spain

Department of Medicine and Surgery, Rey Juan Carlos University, Alcorcón, 28922 Madrid, Spain

References (39)

Show source-provided references
1. American Association of Oral and Maxillofacial Surgeons (2019, July 13). Oral and maxillofacial surgeons: the experts in face, mouth and jaw surgery. Available online: https://myoms.org/procedures/dental-implant-surgery.
2. Grand View Research, Inc. (2019, July 13). Dental Implants Market Size, Share & Trends Analysis Report by Product (Titanium Implants, Zirconium Implants), by Region (North America, Europe, Asia Pacific, Latin America, MEA), And Segment Forecasts, 2018–2024. Available online: https://www.grandviewresearch.com/industry-analysis/dental-implants-market.
3. McGlumphy, E.A., Hashemzadeh, S., Yilmaz, B., Purcell, B.A., Leach, D., and Larsen, P.E. (2019). Treatment of Edentulous Mandible with Metal-Resin Fixed Complete Dentures: A 15- to 20-Year Retrospective Study. Clin. Oral Implants Res., 27.10.1111/clr.13488 ↗
4. Marginal bone loss at implants with different surface characteristics - A 20-year follow-up of a randomized controlled clinical trial10.1111/clr.13145 ↗
5. Long-term (10-year) dental implant survival: A systematic review and sensitivity meta-analysis10.1016/j.jdent.2019.03.008 ↗
6. Osteoblastic cell behaviour on modified titanium surfaces10.1016/j.micron.2017.11.010 ↗
7. Novel surfaces and osseointegration in implant dentistry10.1111/jicd.12349 ↗
8. Scanning electron microscopy and microbiological approaches for the evaluation of salivary microorganisms behaviour on anatase titanium surfaces: In vitro study10.1016/j.morpho.2017.12.001 ↗
9. Ganbold, B., Kim, S.K., Heo, S.J., Koak, J.Y., Lee, Z.H., and Cho, J. (2019). Osteoclastogenesis Behavior of Zirconia for Dental Implant. Materials, 12.10.3390/ma12050732 ↗
10. Gehrke, S.A., Dedavid, B.A., Aramburú, J.S., Pérez-Díaz, L., Calvo Guirado, J.L., Canales, P.M., and De Aza, P.N. (2018). Effect of Different Morphology of Titanium Surface on the Bone Healing in Defects Filled Only with Blood Clot: A New Animal Study Design. Biomed. Res. Int.10.1155/2018/4265474 ↗
11. Effects on the osseointegration of titanium implants incorporating calcium-magnesium: a resonance frequency and histomorphometric analysis in rabbit tibia10.1111/clr.12909 ↗
12. de Lima Cavalcanti, J.H., Matos, P.C., Depes de Gouvêa, C.V., Carvalho, W., Calvo-Guirado, J.L., Aragoneses, J.M., Pérez-Díaz, L., and Gehrke, S.A. (2019). In Vitro Assessment of the Functional Dynamics of Titanium with Surface Coating of Hydroxyapatite Nanoparticles. Materials, 12.10.3390/ma12050840 ↗
13. Assessment of the primary stability of root analog zirconia implants designed using cone beam computed tomography software by means of the Periotest® device: An ex vivo study. A preliminary report10.17219/acem/65069 ↗
14. Impact of Surface Chemistry Modifications on Speed and Strength of Osseointegration10.11607/jomi.5871 ↗
15. Impact of Dental Implant Surface Modifications on Osseointegration10.1155/2016/6285620 ↗
16. Implant surface material, design, and osseointegration10.1016/j.cden.2014.12.003 ↗
17. Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: A laboratory study10.1111/j.1600-0501.2008.01692.x ↗
18. The Effect of Osteotomy Dimension on Implant Insertion Torque, Healing Mode, and Osseointegration Indicators: A Study in Dogs10.1097/ID.0000000000000476 ↗
19. Multiscale Analyses of the Bone-implant Interface10.1177/0022034514566029 ↗
20. Implant compression necrosis: current understanding and case report10.1902/jop.2009.080581 ↗
21. Evaluation of primary and secondary stability of titanium implants using different surgical techniques10.1111/clr.12180 ↗
22. Effect of drilling dimension on implant placement torque and early osseointegration stages: An experimental study in dogs10.1016/j.joms.2011.08.006 ↗
23. The combined effects of undersized drilling and implant macrogeometry on bone healing around dental implants: An experimental study10.1016/j.ijom.2014.03.017 ↗
24. Is there a need for standardization of tightening force used to connect the transducer for resonance frequency analysis in determining implant stability?10.11607/jomi.7361 ↗
25. The effects of superficial roughness and design on the primary stability of dental implants10.1111/j.1708-8208.2009.00202.x ↗
26. Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation
27. Dental implant thread pitch and its influence on the osseointegration process: an in vivo comparison study
28. Implant design considerations for the posterior regions of the mouth10.1097/00008505-199904000-00008 ↗
29. Impact of bone quality and implant type on the primary stability: an experimental study using bovine bone10.1563/AAID-JOI-D-11-00156 ↗
30. Salles, M.B., Allegrini, S., Yoshimoto, M., Pérez-Díaz, L., Calvo-Guirado, J.L., and Gehrke, S.A. (2018). Analysis of Trauma Intensity during Surgical Bone Procedures Using NF-κB Expression Levels as a Stress Sensor: An Experimental Study in a Wistar Rat Model. Materials, 12.10.3390/ma11122532 ↗
31. Evaluation of bone heating, immediate bone cell viability, and wear of high-resistance drills after the creation of implant osteotomies in rabbit tibias
32. Risk factors for dental implant failure: A strategy for the analysis of clustered failure-time observations10.1177/154405910208100814 ↗
33. Implant stability and bone remodeling after 3 and 13 days of implantation with an initial static strain10.1111/cid.12000 ↗
34. A Review of the Impact of Implant Biomaterials on Osteocytes10.1177/0022034518778033 ↗
35. Animal models for implant biomaterial research in bone: a review10.22203/eCM.v013a01 ↗
36. Effects of implant thread geometry on percentage of osseointegration and resistance to reverse torque in the tibia of rabbits10.1902/jop.2004.75.9.1233 ↗
37. Implant materials, designs, and surface topographies: their effect on osseointegration. A literature review
38. Gehrke, S.A., Eliers Treichel, T.L., Pérez-Díaz, L., Calvo-Guirado, J.L., Aramburú Júnior, J., Mazón, P., and de Aza, P.N. (2019). Impact of Different Titanium Implant Thread Designs on Bone Healing: A Biomechanical and Histometric Study with an Animal Model. J. Clin. Med., 31.10.3390/jcm8060777 ↗
39. Osteocyte density in the peri-implant bone of immediately loaded and submerged dental implants10.1902/jop.2009.080484 ↗