CO2 Transcritical Refrigeration Cycle with Dedicated Subcooling: Mechanical Compression vs. Absorption Chiller
Source abstract
Abstract
The objective of this paper is the comparison of two dedicated subcooling methods, after the gas cooler, in a CO2 transcritical refrigeration system. The use of vapor compression refrigeration with R134a for subcooling is the first method, and the second is the use of an absorption chiller that operates with a LiBr-H2O working pair. The examined systems are compared energetically and exegetically with the reference transcritical CO2 refrigeration cycle without subcooling. The analysis is conducted for different operating scenarios and in every case, the system is optimized by selecting the proper temperature and pressure levels. The analysis is performed with a developed and validated model in Engineering Equation Solver. According to the final results, the use of the absorption chiller is able to decrease the system electricity consumption by about 54% compared to the simple transcritical cycle, while the decrease with the mechanical subcooling is 41%. Both systems with dedicated subcooling are found to have an important increase in the system exergy performance compared to the simple transcritical cycle. However, the system with the mechanical subcooling is found to be the best choice exegetically, with a small difference from the system with the absorption chiller.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Refrigeration and Air Conditioning Technologies · Advanced Thermodynamic Systems and Engines · Phase Equilibria and Thermodynamics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Thermal Department, School of Mechanical Engineering, National Technical University of Athens, Zografou, Heroon Polytechniou 9, 15780 Athens, Greece
Funding
Bodossaki Foundation
References (48)
Show source-provided references
1. Wang, J., Shang, S., Li, X., Wang, B., Wu, W., and Shi, W. (2017). Dynamic Performance Analysis for an Absorption Chiller under Different Working Conditions. Appl. Sci., 7.10.3390/app7080797 ↗
2. Bellos, E., and Tzivanidis, C. (2019). Investigation of the Environmentally-Friendly Refrigerant R152a for Air Conditioning Purposes. Appl. Sci., 9.10.3390/app9010119 ↗
3. European Commission (2014). Regulation (EU) No 517/2014 of the European Parliament and of the Council of 16th April 2014 on Fluorinated Greenhouse Gases and Repealing Regulation (EC) No 842/2006, European Commission.
4. Refrigerants: There is still no vision for sustainable solutions10.1016/j.ijrefrig.2017.12.006 ↗
5. Llopis, R., Sánchez, D., Cabello, R., Catalán-Gil, J., and Nebot-Andrés, L. (2018). Conversion of a Direct to an Indirect Refrigeration System at Medium Temperature Using R-134a and R-507A: An Energy Impact Analysis. Appl. Sci., 8.10.3390/app8020247 ↗
6. Natural and synthetic refrigerants, global warming: A review10.1016/j.rser.2018.03.099 ↗
7. Energy and environmental performance assessment of R744 booster supermarket refrigeration systems operating in warm climates10.1016/j.ijrefrig.2015.12.016 ↗
8. Energy analysis of alternative CO2 refrigeration system configurations for retail food applications in moderate and warm climates10.1016/j.enconman.2017.03.020 ↗
9. Energetic and economic analysis of trans-critical CO2 booster system for refrigeration in warm climatic condition10.1016/j.ijrefrig.2017.04.023 ↗
10. The optimum high pressure for CO2 transcritical refrigeration systems with internal heat exchangers10.1016/j.ijrefrig.2005.08.009 ↗
11. Energetic evaluation of an internal heat exchanger in a CO2 transcritical refrigeration plant using experimental data10.1016/j.ijrefrig.2010.07.006 ↗
12. Two-stage transcritical carbon dioxide cycle optimisation: A theoretical and experimental analysis10.1016/j.ijrefrig.2005.09.004 ↗
13. Performance optimization of transcritical CO2 cycle with parallel compression economization10.1016/j.ijthermalsci.2009.12.001 ↗
14. Gullo, P., Elmegaard, B., and Cortella, G. (July, January 29). Energetic, Exergetic and Exergoeconomic Analysis of CO2 Refrigeration Systems Operating in Hot Climates. Proceedings of the ECOS 2015: 28th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems, Pau, France.
15. Experimental analysis of R744 parallel compression cycle10.1016/j.apenergy.2014.08.087 ↗
16. Experimental investigation on the effect of mixing length on the performance of two-phase ejector for CO2 refrigeration cycle with and without heat exchanger10.1016/j.ijrefrig.2010.07.021 ↗
17. Theoretical analysis and optimization of a hybrid CO2 transcritical mechanical compression—Ejector cooling cycle10.1016/j.ijrefrig.2016.10.002 ↗
18. Performance investigation of transcritical carbon dioxide two-stage compression cycle with expander10.1016/j.energy.2006.03.031 ↗
19. Performance analysis of a new ejector expansion refrigeration cycle (NEERC) for power and cold: Exergy and energy points of view10.1016/j.applthermaleng.2017.05.014 ↗
20. Conversion of a direct to an indirect commercial (HFC134a/CO2) cascade refrigeration system: Energy impact analysis10.1016/j.ijrefrig.2016.09.012 ↗
21. Thermodynamic analysis of a novel ejector expansion transcritical CO2/N2O cascade refrigeration (NEETCR) system for cooling applications at low temperatures10.1016/j.energy.2017.04.073 ↗
22. Performance evaluation and optimal configuration analysis of a CO2/NH3 cascade refrigeration system with falling film evaporator–condenser10.1016/j.enconman.2013.12.021 ↗
23. Subcooling methods for CO2 refrigeration cycles: A review10.1016/j.ijrefrig.2018.06.010 ↗
24. Energy improvements of CO2 transcritical refrigeration cycles using dedicated mechanical subcooling10.1016/j.ijrefrig.2015.03.016 ↗
25. Experimental evaluation of a CO2 transcritical refrigeration plant with dedicated mechanical subcooling10.1016/j.ijrefrig.2016.06.009 ↗
26. Nebot-Andres, L., Llopis, R., Sánchez, D., Catalán-Gil, J., and Cabello, R. (2017). CO2 with Mechanical Subcooling vs. CO2 Cascade Cycles for Medium Temperature Commercial Refrigeration Applications Thermodynamic Analysis. Appl. Sci., 7.10.3390/app7090955 ↗
27. Energetic performance of transcritical CO2 refrigeration cycles with mechanical subcooling using zeotropic mixture as refrigerant10.1016/j.energy.2018.02.111 ↗
28. Effects of further cooling the gas cooler outlet refrigerant by an absorption chiller, on a transcritical CO2-compression refrigeration system10.1504/IJEX.2016.078516 ↗
29. Theoretical investigation on performance improvement of a low-temperature transcritical carbon dioxide compression refrigeration system by means of an absorption chiller after-cooler10.1016/j.applthermaleng.2018.04.006 ↗
30. A thermo-economic analysis of a combined cooling system for air conditioning and low to medium temperature refrigeration10.1016/j.jclepro.2018.09.107 ↗
31. Two stage ecological hybrid sorption–compression refrigeration cycle10.1016/j.ijrefrig.2014.08.017 ↗
32. Preliminary conceptual design and thermodynamic comparative study on vapor absorption refrigeration cycles integrated with a supercritical CO2 power cycle10.1016/j.enconman.2018.01.065 ↗
33. Energy and exergy analysis of a combined transcritical CO2 compression refrigeration and single effect H2O-LiBr vapour absorption system10.1504/IJEX.2011.043916 ↗
34. Performance optimization of transcritical CO2 refrigeration cycle with thermoelectric subcooler10.1002/er.1879 ↗
35. CO2 transcritical vapor compression cycle with thermoelectric subcooler10.1080/10789669.2012.625348 ↗
36. Performance improvement of a transcritical CO2 refrigeration cycle using two-stage thermoelectric modules in sub-cooler and gas cooler10.1016/j.ijrefrig.2016.10.007 ↗
37. Thermodynamic performance evaluation of transcritical carbon dioxide refrigeration cycle integrated with thermoelectric subcooler and expander10.1016/j.energy.2017.01.029 ↗
38. The application of a desiccant wheel to increase the energetic performances of a transcritical cycle10.1016/j.enconman.2014.09.066 ↗
39. The substitution of R134a with R744: An exergetic analysis based on experimental data10.1016/j.ijrefrig.2013.06.012 ↗
40. (2018, October 15). F-Chart Software, Engineering Equation Solver (EES). Available online: http://www.fchart.com/ees.
41. Comparitive analysis of an automotive air conditioning systems operating with CO2 and R134a10.1016/S0140-7007(01)00011-1 ↗
42. Performance analysis and optimization of an absorption chiller driven by nanofluid based solar flat plate collector10.1016/j.jclepro.2017.10.313 ↗
43. Energetic, exergetic and financial evaluation of a solar driven absorption chiller—A dynamic approach10.1016/j.enconman.2017.01.041 ↗
44. Parametric analysis and optimization of a solar driven trigeneration system based on ORC and absorption heat pump10.1016/j.jclepro.2017.05.159 ↗
45. Bellos, E., and Tzivanidis, C. (2019). A Theoretical Comparative Study of CO2 Cascade Refrigeration Systems. Appl. Sci., 9.10.3390/app9040790 ↗
46. Advanced exergy analysis of a R744 booster refrigeration system with parallel compression10.1016/j.energy.2016.04.043 ↗
47. Thermodynamic investigation of LiCl-H2O working pair in a double effect absorption chiller driven by parabolic trough collectors10.1016/j.tsep.2017.06.005 ↗
48. Factors influencing the efficiency of photovoltaic system10.1016/j.rser.2018.11.012 ↗