Simulation Analysis and Experiment of Variable-Displacement Asymmetric Axial Piston Pump
Source abstract
Abstract
The variable displacement pump control system has greater energy-saving advantages and application prospects than the valve control system. However, the variable displacement pump control of differential cylinder is not concurrent with the existing technologies. The asymmetric pump-controlled cylinder is, therefore, used to balance the unequal volume flow through a single rod cylinder in closed-circuit system. This is considered to be an effective method. Nevertheless, the asymmetric axial piston pump (AAPP) is a constant displacement pump. In this study, variable-displacement asymmetric axial piston pump (VAPP) is investigated according to the same principle used in investigating AAPP. This study, therefore, aims at investigating the characteristics of VAPP. The variable-displacement output of VAPP is implemented by controlling the swash plate angle with angle feedback control circuit, which is composed of a servo proportional valve and an angular displacement sensor. The angular displacement sensor is connected to the swash plate. The simulation model of VAPP, which is set up through the ITI-SimulationX simulation platform, is used to predict VAPP’s characteristics. The purpose of implementing the experiment is to verify the theoretical results. Both the simulation and the experiment results demonstrated that the swash plate angle is controlled by a variable mechanism; when the swash plate angle increases, the flow of Port B and Port T increases while the response speed of Port B and Port T also accelerates. When the swash plate angle is constant, the flow of Port B and Port T increases along with the increase of pump speed, although the pressure-response speed of Port B is faster than that of Port T. Consequently, the flow pulsation of Port B and Port T tends to decrease gradually along with the increase of pump speed. When the pressure loaded on Port B equals to that of Port T, the flow ripple cycle of Port B is longer than that of Port T, whereas the peak flow of Port B is higher than that of Port T. Since the flow ripple of Port T is bigger than that of Port B, Port T should be connected to the low pressure sides or the oil tank so that it does not affect VAPP’s performance. Further, to avoid the backflow of VAPP from Port T to Port B, Port T cannot be loaded alone, and the loading pressure of Port T also cannot exceed that of Port B.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Hydraulic and Pneumatic Systems · Mechanical Systems and Engineering · Rocket and propulsion systems research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Mechanical Engineering, Taiyuan University of Science and Technology, Taiyuan 030024, China
Institute of Mechatronic Engineering, Taiyuan University of Technology, Taiyuan 030024, China
References (14)
Show source-provided references
1. Current state, problems and the innovative solution of electro-hydraulic technology of pump controlled cylinder10.3901/JME.2008.11.087 ↗
2. Hewett, A.J. (1994). Hydraulic Circuit Flow Control. (5329767), U.S. Patent No.
3. Lawrence, P.D., Salcudean, S.E., Sepehri, N., Chan, D., Bachmann, S., Parker, N., Zhu, M., and Frenette, R. (July, January 30). Coordinated and Force-Feedback Control of Hydraulic Excavators. Proceedings of the 4th International Symposium on Experimental Robotics, ISER’95, Stanford, CA, USA.
4. Rahmfeld, R., Ivantysynova, M., and Weber, J. (2004, January 25–26). Displacement controlled wheel loader—A simple and clever solution. Proceedings of the 4th International Fluid Power Conference, Dresden, Germany.
5. Rahmfeld, R., and Ivantysynova, M. (1998, January 2–3). Energy saving hydraulic actuators for mobile machines. Proceedings of the 1st Bratislavian Fluid Power Symposium, Častá-Píla, Slovakia.
6. Heybroek, K., Larsson, J., and Palmberg, J.O. (2006, January 13–17). Open Circuit Solution for Pump Controlled Actuators. Proceedings of the 4th FPNI PhD Symposium, Sarasota, FL, USA.
7. Williamson, C., and Ivantysynova, M. (2008, January 15–18). Pump mode prediction for four-quadrant velocity control of valveless hydraulic actuators. Proceedings of the 7th JFPS International Symposium on Fluid Power Toyama 2008, Toyama, Japan.10.5739/isfp.2008.323 ↗
8. A hydraulic circuit for single rod cylinders10.1115/1.4004777 ↗
9. Theoretical Analysis and Experimental Research on Characteristics of Parallel Three Assignment Windows Axial Piston Pump10.3901/JME.2011.14.151 ↗
10. Output characteristics of a series three-port axial piston pump10.3901/CJME.2012.03.498 ↗
11. Development of an asymmetric axial piston pump for displacement-controlled system10.1177/0954406213508385 ↗
12. Ivantysyn, J., and Ivantysynova, M. (2001). Hydrostatic Pumps and Motors, Academia Books International.
13. Characteristics of delivery pressure in the axial piston pump with combination of variable displacement and variable speed
14. Optimization of cross angle based on the pumping dynamics model10.1631/jzus.A0900417 ↗