journal article·2017-10-13Open access

Assessment on Stationarity of EMG Signals with Different Windows Size During Isotonic Contractions

Nurhazimah Nazmi, Mohd Abdul Rahman, Shin-ichiroh Yamamoto, Siti Ahmad, MB Malarvili, Saiful Mazlan, Hairi Zamzuri

Applied Sciences· Volume 7· Issue 10

Abstract

In order to analyse surface electromyography (EMG) signals, it is necessary to extract the features based on a time or frequency domain. These approaches are based on the mathematical assumption of signal stationarity. Stationarity of EMG signals is thoroughly examined, especially in isotonic contractions. According to research, conflicting results have been identified depending on varying window sizes. Therefore, in this study, the authors endeavoured to determine the suitable window size to analyse EMG signals during isotonic contractions utilising stationary tests, reverse arrangement (RA), and modified reverse arrangement (MRA). There were slight differences in the average percentages of signal stationarity for RA and MRA tests in 100 ms, 500 ms, and 1000 ms window sizes. However, there was none for the 200 ms window size. On average, a window size of 200 ms provided stationary information with 88.57% of EMG signals compared to other window sizes. This study also recommended the MRA test to determine EMG signals stationarity for future studies, as the performances were better in comparison to RA tests. However, the following recommendation is only valid for window sizes greater than 200 ms. For a real-time application, the size of the analysis window together with the processing time should be less than 300 ms and a window size of 200 ms is applicable for isotonic contractions.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Muscle activation and electromyography studies · Advanced Sensor and Energy Harvesting Materials · Motor Control and Adaptation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Advanced Vehicle System, Malaysia Japan International Institute of Technology, Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, Kuala Lumpur 54100, Malaysia

Department of Bio-science and Engineering, College of Systems Engineering and Science, Shibaura Institute of Technology, Omiya Campus, Fukasaku 307, Saitama 337-8570, Japan

Malaysian Research Institute on Ageing, Universiti Putra Malaysia, 43400 Serdang, Malaysia

Department of Biotechnology and Medical Engineering, Faculty of Biosciences and Medical Engineering, Universiti Teknologi Malaysia, Skudai 81310, Malaysia

References (36)

Show source-provided references
1. Surface Electromyography signal processing and classification techniques10.3390/s130912431 ↗
2. Electromyography (EMG) based classification of neuromuscular disorders using multi-layer perceptron10.1016/j.procs.2015.12.346 ↗
3. Classification of EMG signals using PSO optimized SVM for diagnosis of neuromuscular disorders10.1016/j.compbiomed.2013.01.020 ↗
4. A comparison of EMG-based muscle fatigue assessments during dynamic contractions10.1016/j.jelekin.2013.05.005 ↗
5. EMG-based decoding of grasp gestures in reaching-to-grasping motions10.1016/j.robot.2016.12.014 ↗
6. EMG-based control of a robot arm using low-dimensional embeddings10.1109/TRO.2009.2039378 ↗
7. Kim, M., Lee, J., Ko, H., and Kim, K. (2014, January 12–15). A preliminary analysis of analysis window size and voting size with a time delay for a robust real-time sEMG pattern recognition. Proceedings of the 2014 11th International Conference on Ubiquitous Robots and Ambient Intelligence (URAI), Kuala Lumpur, Malaysia.10.1109/URAI.2014.7057411 ↗
8. Richer, R., Blank, P., Schuldhaus, D., and Eskofier, B.M. (2014, January 16–19). Real-time ECG and EMG analysis for biking using android-based mobile devices. Proceedings of the 2014 11th International Conference on Wearable and Implantable Body Sensor Networks, Zürich, Switzerland.10.1109/BSN.2014.20 ↗
9. Fuzzy logic control for ankle foot orthoses equipped with magnetorheological brake10.11113/.v78.7942 ↗
10. Transradial amputee gesture classification using an optimal number of sEMG sensors: An approach using ICA clustering10.1109/TNSRE.2015.2478138 ↗
11. A review of classification techniques of EMG signals during isotonic and isometric contractions10.3390/s16081304 ↗
12. He, J., Zhang, D., Jiang, N., Sheng, X., Farina, D., and Zhu, X. (2015). User adaptation in long-term, open-loop myoelectric training: Implications for EMG pattern recognition in prosthesis control. J. Neural Eng., 12.10.1088/1741-2560/12/4/046005 ↗
13. Self-recalibrating surface EMG pattern recognition for neuroprosthesis control based on convolutional neural network10.3389/fnins.2017.00379 ↗
14. EMG feature set selection through linear relationship for grasp recognition10.1007/s40846-016-0188-y ↗
15. Fitting distribution for electromyography and electroencephalography signals based on goodness-of-fit tests10.1016/j.procs.2015.12.317 ↗
16. A new strategy for multifunction myoelectric control10.1109/10.204774 ↗
17. Bio-signal based control in assistive robots: A survey10.1016/j.dcan.2015.02.004 ↗
18. Feature reduction and selection for EMG signal classification10.1016/j.eswa.2012.01.102 ↗
19. Support vector machine-based classification scheme for myoelectric control applied to upper limb10.1109/TBME.2008.919734 ↗
20. Al-Ani, A., Koprinska, I., Naik, G.R., and Khushaba, R.N. (2016, January 24–29). A dynamic channel selection algorithm for the classification of EEG and EMG data. Proceedings of the 2016 International Joint Conference on Neural Networks (IJCNN), Vancouver, BC, Canada.10.1109/IJCNN.2016.7727730 ↗
21. Normality and stationarity of EMG Signals of elbow flexor muscles during ramp and step isometric contractions10.1016/S1050-6411(96)00024-7 ↗
22. Lessard, C.S. (2006). Signal Processing of Random Physiological Signals, Morgan & Clypool Publishers.10.1007/978-3-031-01610-3 ↗
23. An examination of the Runs Test, Reverse Arrangements Test, and modified Reverse Arrangements Test for assessing surface EMG signal stationarity10.1016/j.jneumeth.2006.03.011 ↗
24. Stationarity test of electromyographic signals during isokinetic trunk exertions10.3233/WOR-2012-0496-2545 ↗
25. Assessment of the non-Gaussianity and non-linearity levels of simulated sEMG signals on stationary segments10.1016/j.jelekin.2016.12.006 ↗
26. Thongpanja, S., Phinyomark, A., Quaine, F., Laurillau, Y., Wongkittisuksa, B., Limsakul, C., and Phukpattaranont, P. (2013, January 29–31). Effects of window size and contraction types on the stationarity of biceps brachii muscle EMG signals. Proceedings of the 7th International Convention on Rehabilitation Engineering and Assistive Technology, Gyeonggi-do, Korea.
27. Comparison of algorithms for estimation of EMG variables during voluntary isometric contractions10.1016/S1050-6411(00)00025-0 ↗
28. EMG feature evaluation for improving myoelectric pattern recognition robustness10.1016/j.eswa.2013.02.023 ↗
29. A wavelet-based continuous classification scheme for multifunction myoelectric control10.1109/10.914793 ↗
30. Characterization of surface electromyography using time domain features for determining hand motion and stages of contraction10.1007/s13246-014-0243-3 ↗
31. Nazmi, N., Yamamoto, S.I., Abdul Rahman, M.A., Ahmad, S.A., Adiputra, D., Zamzuri, H., and Mazlan, S.A. (2016, January 17–19). Fuzzy logic for walking patterns based on surface electromyography signals with different membership functions. Proceedings of the 2016 6th International Workshop on Computer Science and Engineering, Tokyo, Japan.
32. Bendat, J., and Piersol, A. (2000). Random Data: Analysis and Measurement Procedures, Wiley. [3rd ed.].10.1088/0957-0233/11/12/702 ↗
33. The effects of load, flexion, twisting and window size on the stationarit y of trunk muscle EMG signals10.1016/j.ergon.2012.02.004 ↗
34. Moving approximate entropy applied to surface electromyographic signals10.1016/j.bspc.2007.10.003 ↗
35. Classifcation of ankle joint movements based on surface electromyography signals for rehabilitation robot applications
36. Menon, R., Caterina, G.D., Lakany, H., Petropoulakis, L., Conway, B., and Soraghan, J. (2017). Study on interaction between temporal and spatial information in classification of EMG signals in myoelectric prostheses. IEEE Trans. Neural Syst. Rehabil. Eng.10.1109/TNSRE.2017.2687761 ↗