Towards Management of Residual Limb Volume: Monitoring the Prosthetic Interface Pressure to Detect Volume Fluctuations—A Feasibility Study
Source abstract
Abstract
(1) Motivation: Variations in the volume of the residual limb negatively impact various aspects of prosthesis use including the prosthetic socket fit. Although volume adjustment systems mitigate corresponding fit problems to some extent, some users still find the management of these systems challenging. With the ultimate goal of creating a feedback system that assists users with the management of their volume adjustment systems, this study demonstrates the feasibility of detecting variations in the volume of the residual limb. (2) Methods: Measurements of the interface force at the bottom of the prosthetic socket were used as indicators of variations in the volume of the residual limb. Force sensitive resistors (FSRs) were placed at the bottom of participants’ prosthetic sockets to monitor the interface limb–socket force as participants walked on a flat surface. Two phases of experiments were carried out: The first phase considered variations simulated by three prosthetic sock plies, established the feasibility of detecting variations in the volume of the limb based on the interface force, and further determined the locations at which the interface force could be used to detect variations in the limb’s volume. Having validated the effectiveness of the proposed method in the first phase, the second phase was carried out to determine the smallest detectable variation of the limb’s volume using the proposed method. In this phase, variations simulated by one and two prosthetic sock plies were considered. Four and three volunteers with transtibial amputations participated in the first and the second phases, respectively. (3) Results: Results of the first phase showed that an increase in the volume of the limb resulted in a decrease in the force measured at the distal location of the prosthetic sockets of all participants; however, the smallest detected variation could not be statistically confirmed.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Muscle activation and electromyography studies · Prosthetics and Rehabilitation Robotics · Advanced Sensor and Energy Harvesting Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Menrva Research Group, Schools of Mechatronic Systems Engineering and Engineering Science, Simon Fraser University (Burnaby Mountain Campus), Metro Vancouver, BC V5A 1S6, Canada
Menrva Research Group, Schools of Mechatronic Systems Engineering and Engineering Science, Simon Fraser University (Surrey Campus), Metro Vancouver, BC V3T 0A3, Canada
Barber Prosthetics Clinic, Vancouver, BC V5X 2T4, Canada; brittany@barberprosthetics.com
References (32)
Show source-provided references
1. Reduction of residual limb volume in people with transtibial amputation10.1682/JRRD.2013.11.0243 ↗
2. Residual limb volume change: Systematic review of measurement and management10.1682/JRRD.2010.09.0189 ↗
3. Clinical utility of in-socket residual limb volume change measurement: Case study results10.3109/03093640903214067 ↗
4. Self-reported prosthetic sock use among persons with transtibial amputation10.1177/0309364613499064 ↗
5. National Academies of Sciences, Engineering, and Medicine (2017). The Promise of Assistive Technology to Enhance Activity and Work Participation, National Academies Press.
6. Estimating the Prevalence of Limb Loss in the United States: 2005 to 205010.1016/j.apmr.2007.11.005 ↗
7. Ahmadizadeh, C., and Menon, C. (2019). Investigation of Regression Methods for Reduction of Errors Caused by Bending of FSR-Based Pressure Sensing Systems Used for Prosthetic Applications. Sensors, 19.10.3390/s19245519 ↗
8. How do sock ply changes affect residual limb fluid volume in people with trans-tibial amputation?
9. Medicine and design investigate residual limb volume fluctuations: Three case studies
10. Volume Management: Smart Variable Geometry Socket (SVGS) Technology for Lower-Limb Prostheses10.1097/00008526-200307000-00011 ↗
11. A Device to monitor sock use in people using prosthetic limbs: Technical report10.1682/JRRD.2011.09.0169 ↗
12. Assessment of residual-limb volume change using bioimpedence10.1682/JRRD.2006.08.0096 ↗
13. A bioimpedance analysis platform for amputee residual limb assessment10.1109/TBME.2015.2502060 ↗
14. Biomechanical implications of excessive endograft protrusion into the aortic arch after thoracic endovascular repair10.1016/j.compbiomed.2015.09.011 ↗
15. On the prospect of serum exosomal miRNA profiling and protein biomarkers for the diagnosis of ascending aortic dilatation in patients with bicuspid and tricuspid aortic valve10.1016/j.ijcard.2018.10.005 ↗
16. Multi-material 3-D viscoelastic model of a transtibial residuum from in-vivo indentation and MRI data10.1016/j.jmbbm.2016.02.020 ↗
17. Changes in interface pressures and shear stresses over time on trans-tibial amputee subjects ambulating with prosthetic limbs: Comparison of diurnal and six-month differences10.1016/j.jbiomech.2004.08.008 ↗
18. Real-time patient-specific finite element analysis of internal stresses in the soft tissues of a residual limb: A new tool for prosthetic fitting10.1007/s10439-006-9208-3 ↗
19. State-of-the-art research in lower-limb prosthetic biomechanics-socket interface: A review
20. A Variable-Impedance Prosthetic Socket for a Transtibial Amputee Designed from Magnetic Resonance Imaging Data10.1097/JPO.0b013e31829be19c ↗
21. Effects of fluid insert volume changes on socket pressures and shear stresses: Case studies from two trans-tibial amputee subjects10.1080/03093640600810266 ↗
22. A noncontact sensor for measurement of distal residual-limb position during walking10.1682/JRRD.2004.11.0143 ↗
23. Clinical study: Changes in interface pressure and stump shape over time: Preliminary results from a trans-tibial amputee subject10.1080/03093640008726539 ↗
24. Pseudoreplication revisited10.2307/2265754 ↗
25. Towards understanding and use of mixed-model analysis of agricultural experiments10.4141/CJPS10049 ↗
26. Normality tests for statistical analysis: A guide for non-statisticians10.5812/ijem.3505 ↗
27. Sall, J., Stephens, M.L., Lehman, A., and Loring, S. (2017). JMP Start Statistics: A Guide to Statistics and Data Analysis Using JMP, Sas Institute.
28. Investigation of Feature Selection for Gesture Classification for Prosthesis Control Using Force Myography: A Case Study10.3389/fbioe.2019.00331 ↗
29. A proportional control scheme for high density force myography10.1088/1741-2552/aac89b ↗
30. Preliminary evaluation of a novel bladder-liner for facilitating residual-limb fluid volume recovery without doffing10.1682/JRRD.2014.12.0316 ↗
31. Real-time subject-specific analyses of dynamic internal tissue loads in the residual limb of transtibial amputees10.1016/j.medengphy.2009.12.006 ↗
32. Statistical significance and statistical power in hypothesis testing10.1002/jor.1100080221 ↗