journal article·2025-07-24Open access

Chest Compression Skill Evaluation System Using Pose Estimation and Web-Based Application

Ryota Watanabe, Jahidul Islam, Xin Zhu, Emiko Kaneko, Ken Iseki, Lei Jing

Applied Sciences· Volume 15· Issue 15

Abstract

It is critical to provide life-sustaining treatment to OHCA patients before ambulance care arrives. However, incorrectly performed resuscitation maneuvers reduce the chances of survival and recovery for the victims. Therefore, we must train regularly and learn how to do it correctly. To facilitate regular chest compression training, this study aims to improve the accuracy of a chest compression evaluation system using posture estimation and to develop a web application. To analyze and enhance accuracy, the YOLOv8 posture estimation was used to examine compression depth, recoil, and tempo, and its accuracy was compared to that of the manikin, which has evaluation systems. We conducted comparative experiments with different camera angles and heights to optimize the accuracy of the evaluation. The experimental results showed that an angle of 30 degrees and a height of 50 cm produced superior accuracy. For web application development, a system has been designed to allow users to upload videos for analysis and obtain appropriate compression parameters. The usability evaluation of the application confirmed its ease of use and accessibility, and positive feedback was obtained. In the conclusion, these findings suggest that optimizing recording conditions significantly improves the accuracy of posture-based chest compression evaluation. Future work will focus on enhancing real-time feedback functionality and improving the user interface of the web application.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Simulation-Based Education in Healthcare · Cardiac Arrest and Resuscitation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Human Intelligent Sensing (iSensing) Lab, University of Aizu, Aizu-Wakamatsu 965-8580, Japan

Department of AI Technology Development, M&D Data Science Center, Institute of Integrated Research, Institute of Science Tokyo, Tokyo 101-0062, Japan

Center for Language Research, University of Aizu, Aizu-Wakamatsu 965-8580, Japan

Department of Emergency and Critical Care, Fukushima Medical University, Fukushima 960-1295, Japan

References (15)

Show source-provided references
1. FDMA (2025, March 30). Status of Emergency Services Provided by Ambulance Vehicles in 2020. Available online: https://www.fdma.go.jp/publication/hakusho/r2/chapter2/section5/56699.html.
2. Global incidence of out-of-hospital cardiac arrest and survival rates: Systematic review and meta-analysis10.1186/s13054-020-2773-2 ↗
3. Mechanical devices for cardiopulmonary resuscitation
4. Quality of cardiopulmonary resuscitation in out-of-hospital cardiac arrest before and after introduction of a mechanical chest compression device, LUCAS-2; a prospective, observational study10.1186/s13049-015-0114-2 ↗
5. Impact of a corpuls CPR Mechanical Chest Compression Device on chest compression quality during extended pediatric manikin resuscitation: A randomized crossover pilot study10.5603/DEMJ.2017.0012 ↗
6. The effects of a newly developed miniaturized mechanical chest compressor on outcomes of cardiopulmonary resuscitation in a porcine model10.1097/CCM.0b013e31825d924d ↗
7. Haemodynamic effects of adrenaline (epinephrine) depend on chest compression quality during cardiopulmonary resuscitation in pigs10.1016/j.resuscitation.2006.05.003 ↗
8. Manual versus automatic chest compression devices for cardiopulmonary resuscitation under zero gravity (The MACCC - 0G STUDY)10.1016/j.resuscitation.2024.110385 ↗
9. Takayama, W., Endo, A., Morishita, K., and Otomo, Y. (2023). Manual Chest Compression versus Automated Chest Compression Device during Day-Time and Night-Time Resuscitation Following Out-of-Hospital Cardiac Arrest: A Retrospective Historical Control Study. J. Pers. Med., 13.10.21203/rs.3.rs-2501124/v1 ↗
10. Chest Compression Evaluation based on Pose Estimation10.37394/23208.2024.21.32 ↗
11. Japan Resuscitation Council (2025, March 30). JRC Guideline 2020. Available online: https://www.jrc-cpr.org/jrc-guideline-2020/.
12. Reliability of the System Usability Scale (SUS) in the field of prosthetics and orthotics
13. Sumitomo Electric Industries, Ltd. (2021). Future-Oriented Technologies by Sumitomo Electric for Next-Generation Vehicles. SEI Tech. Rev., 190, 31–36. Available online: https://sumitomoelectric.com/jp/sites/japan/files/2021-10/download_documents/J190-31.pdf.
14. ResusTime: Measuring Cardiopulmonary Resuscitation Performance Using Smartwatches10.1145/3610894 ↗
15. Nishimura, K., Noda, Y., Hayashi, Y., and Takagi, H. (2022, January 28–30). CPR quality measurement using glove-type sensors. Proceedings of the Annual Conference of the Japanese Society for Medical and Biological Engineering, Niigata, Japan.