Positron emission tomography (PET) is an imaging modality for non-invasive visualization and quantification of molecular pathways in human diseases, with applications spanning clinical practice and biomedical research. Recent advances in PET system technology target ultra-high spatial resolution (<2 mm) to enhance diagnostic precision for early-stage disease detection and longitudinal monitoring. A key strategy involves organ-specific, or loco-regional, scanner configurations that optimize photon detection efficiency (PDE) while balancing the trade-off between spatial resolution and image signal-to-noise ratio (SNR). This study reviews innovations driving the development of next-generation clinical PET systems, including the following: (1) novel geometries tailored for anatomical regions such as the head/neck and breast, (2) high-performance detector materials and readout electronics, and (3) advanced image reconstruction algorithms. This paper emphasizes progress toward achieving ≤2 mm isotropic spatial resolution in clinical PET systems, and in particular focuses on describing a 1 mm3 resolution system dedicated to head-and-neck or breast cancer imaging that was developed in our laboratory.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Medical Imaging Techniques and Applications · Radiation Detection and Scintillator Technologies · Atomic and Subatomic Physics Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Electrical Engineering, Stanford University, Stanford, CA 94305, USA
Department of Radiology, Stanford University, Stanford, CA 94305, USA
Department of Bioengineering, Stanford University, Stanford, CA 94305, USA
Department of Physics, Stanford University, Stanford, CA 94305, USA
Funding
The Stanford-Coulter Translational Research Program · The Emerson Collective Cancer Research Fund · National Institutes of Health, National Cancer Institute (NIH-NC)
References (78)
Show source-provided references
1. Positron emission tomography-magnetic resonance imaging: Technical review10.1053/j.ro.2014.10.001 ↗
2. Elangovan, A., and Jeyaseelan, T. (2016, January 24–26). Medical imaging modalities: A survey. Proceedings of the 2016 International Conference on Emerging Trends in Engineering, Technology and Science (ICETETS), Pudukkottai, India.10.1109/ICETETS.2016.7603066 ↗
3. PET/MR imaging: Technical aspects and potential clinical applications10.1148/radiol.13121038 ↗
4. Kim, E.E., Lee, M.C., Inoue, T., and Wong, W.H. (2012). Clinical PET and PET/CT: Principles and Applications, Springer Science & Business Media.10.1007/978-1-4419-0802-5 ↗
5. Dong, Q., Ullah, M.N., Innes, D., Watkins, R.D., Chang, C.M., Zou, S.J., Groll, A., Sacco, I., Chinn, G., and Levin, C.S. (2024). PETcoil: First results from a second-generation RF-penetrable TOF-PET brain insert for simultaneous PET/MRI. Phys. Med. Biol., 69.10.1088/1361-6560/ad7221 ↗
6. Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner10.2967/jnumed.111.092726 ↗
7. NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system10.1118/1.4945416 ↗
8. Performance Characteristics of the Whole-Body Discovery IQ PET/CT System10.2967/jnumed.116.185561 ↗
9. Performance Evaluation of the Vereos PET/CT System According to the NEMA NU2-2012 Standard10.2967/jnumed.118.215541 ↗
10. Performance Characteristics of the Digital Biograph Vision PET/CT System10.2967/jnumed.118.215418 ↗
11. Comparison of NEMA characterizations for Discovery MI and Discovery MI-DR TOF PET/CT systems at different sites and with other commercial PET/CT systems10.1186/s40658-020-0271-x ↗
12. Cherry, S.R., Sorenson, J.A., and Phelps, M.E. (2013). Physics in Nuclear Medicine, Saunders.10.1016/B978-1-4160-5198-5.00001-0 ↗
13. Physical principles and technology of clinical PET imaging10.47102/annals-acadmedsg.V33N2p133 ↗
14. Advances in Detector Instrumentation for PET10.2967/jnumed.121.262509 ↗
15. El Ouaridi, A., Ait Elcadi, Z., Mkimel, M., Bougteb, M., and El Baydaoui, R. (2024). The detection instrumentation and geometric design of clinical PET scanner: Towards better performance and broader clinical applications. Biomed. Phys. Eng. Express, 10.10.1088/2057-1976/ad2d61 ↗
16. Scintillation crystals for PET
17. A comparative study of the luminescence properties of LYSO: Ce, LSO: Ce, GSO: Ce and BGO single crystal scintillators for use in medical X-ray imaging10.1016/j.ejmp.2008.01.007 ↗
18. Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution10.1088/0031-9155/44/3/019 ↗
19. Wavelength discrimination (WLD) detector optimization for time-of-flight positron emission tomography with depth of interaction information10.1016/j.nima.2020.164498 ↗
20. Resolution modeling in PET imaging: Theory, practice, benefits, and pitfalls10.1118/1.4800806 ↗
21. Fundamental limits of spatial resolution in PET10.1016/j.nima.2010.11.092 ↗
22. Annihilation photon acollinearity in PET: Volunteer and phantom FDG studies10.1088/0031-9155/52/17/010 ↗
23. Physics of pure and non-pure positron emitters for PET: A review and a discussion10.1186/s40658-016-0144-5 ↗
24. National Institute of Standards and Technology (2022, April 04). National Institute of Standards and Technology, Available online: https://www.nist.gov.
25. Laboratoire National Henri Becquerel (2022, April 04). Laboratoire National Henri Becquerel. Available online: http://www.lnhb.fr/.
26. Brookhaven National Laboratory (2022, April 04). Brookhaven National Laboratory, Available online: https://www.bnl.gov/.
27. Fabrication and Characterization of a 0.5-mm Lutetium Oxyorthosilicate Detector Array for High-Resolution PET Applications
28. High-resolution PET detector design: Modelling components of intrinsic spatial resolution10.1088/0031-9155/50/2/001 ↗
29. Levin, C.S. (2001, January 4–10). Design of a high resolution and high sensitivity scintillation crystal array with nearly perfect light collection. Proceedings of the 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310), San Diego, CA, USA.
30. Levin, C.S., Foudray, A.M.K., Olcott, P.D., and Habte, F. (2003, January 19–25). Investigation of position sensitive avalanche photodiodes for a new high resolution PET detector design. Proceedings of the 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515), Portland, OR, USA.
31. Lewellen, T.K. (2008). Recent developments in PET detector technology. Phys. Med. Biol., 53.10.1088/0031-9155/53/17/R01 ↗
32. Development of a prototype PET scanner with depth-of-interaction measurement using solid-state photomultiplier arrays and parallel readout electronics10.1088/0031-9155/59/5/1223 ↗
33. Du, J., Bai, X., and Cherry, S.R. (2019). Performance comparison of depth-encoding detectors based on dual-ended readout and different {SiPMs} for high-resolution {PET} applications. Phys. Med. Biol., 64.10.1088/1361-6560/ab1c37 ↗
34. Kuang, Z., Wang, X., Ren, N., Wu, S., Gao, J., Zeng, T., Gao, D., Zhang, C., Sang, Z., and Hu, Z. (2020). Design and performance of SIAT aPET: A uniform high-resolution small animal PET scanner using dual-ended readout detectors. Phys. Med. Biol., 65.10.1088/1361-6560/abbc83 ↗
35. Lewellen, T.K., Janes, M., and Miyaoka, R.S. (2004, January 16–22). DMice-a depth-of-interaction detector design for PET scanners. Proceedings of the IEEE Symposium Conference Record Nuclear Science 2004, Rome, Italy.
36. A Crosshair Light Sharing PET Detector With DOI and TOF Capabilities Using Four-to-One Coupling and Single-Ended Readout10.1109/TRPMS.2020.3032466 ↗
37. Evaluation of high-resolution and depth-encoding PET detector modules based on single-ended readout with TOFPET2 ASIC10.1007/s41605-021-00270-9 ↗
38. Performance characterization of a new high resolution PET scintillation detector10.1088/0031-9155/55/19/018 ↗
39. Study of the performance of a novel resolution dual-panel PET camera design dedicated to breast cancer imaging using Monte Carlo simulation10.1118/1.2409480 ↗
40. Qi, J., and Leahy, R.M. (2006). Iterative reconstruction techniques in emission computed tomography. Phys. Med. Biol., 51.10.1088/0031-9155/51/15/R01 ↗
41. Recent developments in time-of-flight PET10.1186/s40658-016-0138-3 ↗
42. Wang, Y. (2021). High SPATIAL Resolution Dedicated Head and Neck Positron Emission Tomography System Based on Cadmium Zinc Telluride Detectors, University of California.
43. Experimental evaluation of a 3-D CZT imaging spectrometer for potential use in Compton-Enhanced PET imaging10.1109/TRPMS.2022.3200010 ↗
44. Assessment of CZT Dual Panel PET as total-body imaging in small animal with high spatial resolution and multi-sample capability
45. A simulation of a high-resolution cadmium zinc telluride positron emission tomography system10.1002/mp.16856 ↗
46. Development of a 3D brain PET scanner using CdTe semiconductor detectors and its first clinical application10.1109/TNS.2011.2146790 ↗
47. Cherlin, A., Wirth, A., Erlandsson, K., Baistow, I., Thielemans, K., and Hutton, B.F. (2021, January 16–23). A new concept for a low-dose stationary tomographic molecular breast imaging camera using 3D position sensitive CZT detectors. Proceedings of the 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Virtual.10.1109/NSS/MIC44867.2021.9875650 ↗
48. Gu, Y., Matteson, J., Skelton, R., Deal, A., Stephan, E., Duttweiler, F., Gasaway, T., and Levin, C. (2011). Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET. Phys. Med. Biol., 56.10.1088/0031-9155/56/6/004 ↗
49. Jiang, W., Chalich, Y., and Deen, M.J. (2019). Sensors for positron emission tomography applications. Sensors, 19.10.3390/s19225019 ↗
50. Design and Performance of a 1 mm3 Resolution Clinical PET System Comprising 3-D Position Sensitive Scintillation Detectors10.1109/TMI.2018.2799619 ↗
51. The ECAT HRRT: Performance and first clinical application of the new high resolution research tomograph10.1109/TNS.2002.998689 ↗
52. Performance evaluation of a high-resolution brain PET scanner using four-layer MPPC DOI detectors10.1088/1361-6560/aa82e8 ↗
53. Initial Results of the MINDView PET Insert Inside the 3T mMR10.1109/TRPMS.2018.2866899 ↗
54. The System Design, Engineering Architecture, and Preliminary Results of a Lower-Cost High-Sensitivity High-Resolution Positron Emission Mammography Camera10.1109/TNS.2009.2031644 ↗
55. Performance Evaluation of a New Dedicated Breast PET Scanner Using NEMA NU4-2008 Standards10.2967/jnumed.113.131565 ↗
56. Design and evaluation of the MAMMI dedicated breast PET10.1118/1.4742850 ↗
57. Performance Characteristics of the NeuroEXPLORER, a Next-Generation Human Brain PET/CT Imager10.2967/jnumed.124.267767 ↗
58. The ECAT HRRT: NEMA NEC evaluation of the HRRT system, the new high-resolution research tomograph10.1109/TNS.2002.803784 ↗
59. A four-Layer depth of interaction detector block for small animal PET10.1109/TNS.2004.835739 ↗
60. Performance evaluation of a high resolution dedicated breast PET scanner10.1118/1.4945271 ↗
61. Chin, M., Innes, D., and Levin, C.S. (November, January 31). Results from a Further Scaled up Prototype of a 1-millimeter Resolution Clinical PET System. Proceedings of the 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Boston, MA, USA.10.1109/NSS/MIC42677.2020.9507819 ↗
62. A New Positioning Algorithm for Position-Sensitive Avalanche Photodiodes10.1109/TNS.2007.894129 ↗
63. Lau, F.W.Y., Vandenbroucke, A., Reynolds, P.D., Olcott, P.D., Horowitz, M.A., and Levin, C.S. (2010). Analog signal multiplexing for PSAPD-based PET detectors: Simulation and experimental validation. Phys. Med. Biol., 55.10.1088/0031-9155/55/23/001 ↗
64. Convex Optimization of Coincidence Time Resolution for a High-Resolution PET System10.1109/TMI.2010.2080282 ↗
65. Promising new photon detection concepts for high-resolution clinical and preclinical PET10.2967/jnumed.110.084343 ↗
66. Signal Conditioning Technique for Position Sensitive Photodetectors to Manipulate Pixelated Crystal Identification Capabilities10.1109/TNS.2012.2209893 ↗
67. Influence of temperature and bias voltage on the performance of a high resolution {PET} detector built with position sensitive avalanche photodiodes10.1088/1748-0221/7/08/P08001 ↗
68. Zhai, J., Vandenbroucke, A., and Levin, C.S. (2014). Thermal regulation for APDs in a 1 mm3 resolution clinical PET camera: Design, simulation and experimental verification. Phys. Med. Biol., 59.10.1088/0031-9155/59/14/3951 ↗
69. Programmable High Voltage Distribution for Photodetectors in a 1 mm Resolution Clinical PET System10.1109/TNS.2015.2440437 ↗
70. Thermal regulation of tightly packed solid-state photodetectors in a 1 mm3 resolution clinical PET system10.1118/1.4903889 ↗
71. Hsu, D.F.C., Freese, D.L., Innes, D.R., and Levin, C.S. (2019). Intercrystal scatter studies for a 1 mm3 resolution clinical PET system prototype. Phys. Med. Biol., 64.10.1088/1361-6560/ab115b ↗
72. Time Resolution Studies for a 1-mm Resolution Clinical PET System With a Charge Sharing Readout and Leading Edge Discrimination10.1109/TRPMS.2018.2885704 ↗
73. Position sensitive APDs for small Animal PET imaging10.1109/TNS.2003.823012 ↗
74. Tumer, T.O., Cajipe, V.B., Clajus, M., Hayakawa, S., and Volkovskii, A. (November, January 29). Multi-Channel Front-End Readout IC for Position Sensitive Solid-State Detectors. Proceedings of the 2006 IEEE Nuclear Science Symposium Conference Record, San Diego, CA, USA.10.1109/NSSMIC.2006.356181 ↗
75. Reynolds, P.D., Vandenbroucke, A., Freese, D., Hsu, D., Innes, D., and Levin, C.S. (2014, January 8–15). Stackable electronics architecture for densely packed PET detectors. Proceedings of the 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Seattle, WA, USA.10.1109/NSSMIC.2014.7430767 ↗
76. Comparison of Gallium-68 and Fluorine-18 imaging characteristics in positron emission tomography10.1016/j.apradiso.2012.06.034 ↗
77. Sauerzapf, S., Thomas, L., Behe, M., Weber, W., Zakhnini, A., Pietrzyk, U., and Mix, M. (2011, January 23–29). Using Monte-Carlo simulations to implement corrections for I-124 as a non-pure positron emitter in small animal and human PET imaging. Proceedings of the 2011 IEEE Nuclear Science Symposium Conference Record, Valencia, Spain.10.1109/NSSMIC.2011.6152950 ↗
78. Unparalleled and revolutionary impact of PET imaging on research and day to day practice of medicine10.1515/bams-2021-0186 ↗