The Mathematical Model Based on the Parameters of Simulation Results Predicts the Fire Extinguishing Resource Demand of Naval Fires
Source abstract
Abstract
In recent years, due to the diversity of fire scenes in ports and ships, the problem of fire command is complicated. In the case of power failure, the original command platform and fire extinguishing system will not be able to be used normally, or the fire extinguishing resources carried by the ship when it is on fire cannot be used. In the traditional firefighting ability research, there is no clear measure of firefighting ability, resulting in inaccurate calculation results. By corresponding to the quantity and composition of resources for the study of fire extinguishing capability, the combination of the fire dynamics simulation software PyroSim2020 and a calculation model that converts its resources into the total amount and flow of fire extinguishing agent can be provided. Based on the analytic hierarchy process (AHP), a firefighting demand grade calculation and judgment model was established, which included five factors: fire scale, combustion material characteristics, foam extinguishing agent performance, firefighting object characteristics, and external factors. It concluded that the demand assignment values of each index element were 2, 5, 6, 9, and 10, and further proposed the grade judgment criteria for the calculation results of comprehensive fire demand. Through the quantitative simulation of firefighting demand based on the fire scenario and calculation model test of the consumption prediction of cooperative firefighting equipment, it can also provide a strategic reference for related cooperative fire rescue.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Fire Detection and Safety Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Power Engineering Institute, Naval University of Engineering, Wuhan 430030, China
Safety Science and Emergency Management Institute, Wuhan University of Technology, Wuhan 430062, China
Funding
National key research and development plan project
References (25)
Show source-provided references
1. A Fire Dynamics Simulator approximation of non-toxic smoke10.1088/1755-1315/664/1/012098 ↗
2. Performability evaluation, validation and optimization for the steam generation system of a coal-fired thermal power plant10.1016/j.mex.2022.101852 ↗
3. Simulation of flames and smoke spreading in an underground garage under different ventilation conditions10.1088/1742-6596/1736/1/012050 ↗
4. A method to produce a flexible and customized fuel models dataset10.1016/j.mex.2023.102218 ↗
5. A novel approach to fuel biomass sampling for 3D fuel characterization10.1016/j.mex.2018.11.006 ↗
6. Study on Parameters setting of Semi Transverse Smoke Exhaust in Subway Tunnel10.1088/1755-1315/825/1/012039 ↗
7. Research on the Fire of High-rise Residential Building Based on Pyrosim Numerical Simulation10.1088/1755-1315/455/1/012059 ↗
8. Research on Influence and Prediction Model of Urban Traffic Link Tunnel curvature on Fire Temperature Based on Pyrosim—SPSS Multiple Regression Analysis10.1088/1755-1315/153/6/062032 ↗
9. A fire simulation method of urban light rail station hall based on building information model and pyrosim software10.1088/1742-6596/1903/1/012065 ↗
10. Condensed Aerosol Based Fire Extinguishing System Covering Versatile Applications: A Review10.1007/s10694-021-01148-4 ↗
11. Facile synthesis of rGO/Fe2O3 nanocomposite and its combination with aerosol forming composite for ultra-fast fire extinguishment10.1007/s10853-022-08130-7 ↗
12. Gałaj, J., Tuśnio, N., Wolny, P., and Drzymała, T. (2020). Analysis of the Impact of Water Flow Rate on the Temperature Variability in a Closed Room during the Extinguishing of A-Group Fire Using a Hybrid Water Mist Suppression System. Sustainability, 12.10.3390/su12208700 ↗
13. Research on thermal response of pool fire of oil tank based on PyroSim10.1088/1755-1315/565/1/012090 ↗
14. Prakash, B., Saxena, A., Tyagi, Y.K., Devi, K., Tanwar, R.K., and Kumar, A. (2024). Maltose-based pyrotechnic aerosol forming composites for fire extinguishing application. FirePhysChem, 23–39.10.1016/j.fpc.2024.09.003 ↗
15. Fire risk assessment of alternative ship design10.1080/17445302.2016.1275474 ↗
16. Study on the Effect of Pressurized Air Supply Outlet Setting on the Effect of Anteroom Smoke Control10.1088/1742-6596/2445/1/012002 ↗
17. Modelling of fire risks in an offshore facility10.1016/j.firesaf.2014.11.019 ↗
18. Fire Safety of Integrated Pipeline Corridor Cable Block Based on Numerical Simulation10.1088/1742-6596/2074/1/012092 ↗
19. Simulation of fire smoke disaster in a goaf during the closure process10.2298/TSCI200630323Z ↗
20. Safest-path planning approach for indoor fire evacuation10.1016/j.ijdrr.2023.103760 ↗
21. Simulation of a typical fire process in a gas station10.1088/1755-1315/770/1/012054 ↗
22. PyroSim-Based Numerical Simulation of Fire Safety and Evacuation Behaviour of College Buildings10.18280/ijsse.100218 ↗
23. Simulation study on fire and evacuation of super high-rise commercial building10.1016/j.csite.2023.103519 ↗
24. Numerical Simulation of Fire in Underground Commercial Street
25. Analysis of the indoor fire risk based on the Pyrosim simulation10.1088/1755-1315/636/1/012002 ↗