Structural Health Monitoring for Prefabricated Building Envelope under Stress Tests
Source abstract
Abstract
This paper details the comprehensive activities conducted in a laboratory setting to assess the structural health monitoring (SHM) of prefabricated building envelopes. Integrating sensors into building components like curtain wall facades poses challenges but offers opportunities for monitoring structural health, requiring compliance with regulatory standards. The research investigates the possibility of defining a kit of conventional and multi-parameter sensors integrated within the building envelope to monitor its behavior during the performance test conducted. The kit of sensors also includes Fiber Optic Sensors for effectively monitoring building envelope behavior and structural integrity. In this context, the European project InComEss (H2020-GA862597) aims to define a stand-alone solution for SHM using Piezoelectric Energy Harvesting Systems (PE-EHS) for façade monitoring through FBG/FOS system. After analyzing the main façade structural stress, a series of FBGs, accelerometers, and force washers were integrated within a 1:1 scale façade prototype and tested in a laboratory following the test sequence parameters required by the curtain wall standard EN 13830. The data collected were analyzed with the aim of monitoring the façade behavior before and after the tests. The results show that the façade’s performance passed the assessing test criteria without reporting any damages. In addition, the outcomes demonstrated the effectiveness of the defined kit of multi-parameter sensors for the building envelope’s SHM.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Structural Health Monitoring Techniques · Advanced Fiber Optic Sensors · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Focchi S.p.A., 47824 Poggio Torriana, Italy
Department of Industrial Engineering and Mathematical Sciences, Università Politecnica delle Marche, 60131 Ancona, Italy
PhotonFirst International, 1812 SC Alkmaar, The Netherlands
Levery S.r.l. Società Benefit, 47814 Bellaria Igea Marina, Italy
Funding
European Union’s Horizon 2020 Research and Innovation Program
References (46)
Show source-provided references
1. Wang, G., and Ke, J. (2024). Literature Review on the Structural Health Monitoring (SHM) of Sustainable Civil Infrastructure: An Analysis of Influencing Factors in the Implementation. Buildings, 14.10.3390/buildings14020402 ↗
2. (2024, January 29). Intelligent Buildings—An Overview|ScienceDirect Topics. Available online: https://www.sciencedirect.com/topics/engineering/intelligent-buildings.
3. Blum, D. (2023). Data-Driven Smart Buildings: State-of-the-Art Review, Energy in Building and Communities Programme.
4. Kaboli, A., and Shirowzhan, S. (2021). Advances and Technologies in Building Construction and Structural Analysis, IntechOpen.10.5772/intechopen.88410 ↗
5. Faridi, A., Roy, K., and Singhal, V. (2024). Damage Quantification in Beam-Type Structures Using Modal Curvature Ratio, Springer International Publishing. Innovative Infrastructure Solutions.10.1007/s41062-023-01353-w ↗
6. Structural Health Monitoring of Buildings and Infrastructure
7. Ferreira, P.M., Machado, M.A., Carvalho, M.S., and Vidal, C. (2022). Embedded Sensors for Structural Health Monitoring: Methodologies and Applications Review. Sensors, 22.10.20944/preprints202210.0414.v1 ↗
8. Structural Health Monitoring System of Bridges10.1016/j.proeng.2017.09.472 ↗
9. Deng, Z., Huang, M., Wan, N., and Zhang, J. (2023). The Current Development of Structural Health Monitoring for Bridges: A Review. Buildings, 13.10.3390/buildings13061360 ↗
10. Field Monitoring and Prediction on Temperature Distribution of Glass Curtain Walls of a Super High-Rise Building10.1016/j.engstruct.2021.113405 ↗
11. Monitoring of Wind Effects on a Wind-Sensitive Hybrid Structure with Single-Layer Cable-Net Curtain Walls under Typhoon Muifa10.1016/j.jobe.2021.102960 ↗
12. Ogasawara, S., Kanda, K., and Suzuki, Y. (2020, January 13–18). Damage Investigation of Non-Structural Components in Buildings with SHM System in the 2018 Osaka Earthquake. Proceedings of the 17th World Conference on Earthquake Engineering, Sendai, Japan.
13. Brell-Cokcan, S., Adams, T.J., Kerber, E., Dai, R., Lee, H.J., Kirner, L.T., von Hilchen, M., and Adams, T.J. (2022). Construction & Robotics: Research Driven Project, Volume 1: Research Paper/SS 2021, RWTH Aachen University.10.1007/978-3-642-41610-1_218-1 ↗
14. Building Facade Inspection: A System Based on Automated Data Acquisition, Machine Learing, and Deep Learning Image Classification Methods
15. Giovanardi, M., Baietta, A., Belletti, F., Magnani, S., Casadei, O., and Pracucci, A. (2024). Exploiting the Value of Active and Multifunctional Façade Technology through the IoT and AI. Appl. Sci., 14.10.3390/app14031145 ↗
16. (2022). Curtain Walling. Standard No. EN13830-2022.
17. Armstrong, S., Auty, M., Aylward, T., Campbell, J., Claridge, P., and De Bleecker, H. (2005). Standard Test Methods for Building Envelopes, Centre of Window and Cladding Technology.
18. Fibre Bragg Gratings in Structural Health Monitoring—Present Status and Applications10.1016/j.sna.2008.04.008 ↗
19. Fibre Optic Sensors for the Structural Health Monitoring of Building Structures10.1016/j.protcy.2016.08.065 ↗
20. Advancing Structural Health Monitoring: A Vibration-Based IoT Approach for Remote Real-Time Systems10.1016/j.sna.2023.114863 ↗
21. Capacitive Accelerometers at Low Frequency for Infrastructure Monitoring10.1016/j.prostr.2023.01.156 ↗
22. SHM of Historical Buildings: The Case Study of Santa Maria in Via Church in Camerino (Italy)10.1016/j.prostr.2023.01.268 ↗
23. Correlation of Local and Global Structural Damage State for SHM10.1016/j.prostr.2023.01.118 ↗
24. Substructure Damage Identification Based on Wavelet-Domain Response Reconstruction10.1177/1475921714532991 ↗
25. Structural Damage Identification with Power Spectral Density Transmissibility: Numerical and Experimental Studies10.12989/sss.2015.15.1.015 ↗
26. SHM System for Anomaly Detection of Bolted Joints in Engineering Structures10.1016/j.istruc.2021.06.086 ↗
27. (2024, January 29). InComEss. Available online: https://www.incomess-project.com.
28. Pracucci, A., Vandi, L., Belletti, F., Melo, A.R.A., Vlachos, M., Amditis, A., Calcagni, M.T., and Esteves, D.S. (2024). Integration of Piezoelectric Energy Harvesting Systems in Building Envelope for Structural Health Monitoring with Fiber Optic Sensing Technology. Preprints.10.20944/preprints202403.1168.v1 ↗
29. Optimization of a Piezoelectric Wind-Excited Cantilever for Energy Harvesting from Facades10.1007/978-3-031-10776-4_97 ↗
30. Ye, X.-W., Su, Y.-H., and Xi, P.-S. (2018). Statistical Analysis of Stress Signals from Bridge Monitoring by FBG System. Sensors, 18.10.3390/s18020491 ↗
31. Ansari, F. (2005). Sensing Issues in Civil Structural Health Monitoring, Springer.10.1007/1-4020-3661-2 ↗
32. Čápová, K., Velebil, L., and Včelák, J. (2020). Laboratory and In-Situ Testing of Integrated FBG Sensors for SHM for Concrete and Timber Structures. Sensors, 20.10.3390/s20061661 ↗
33. Fibre Bragg Grating Sensors as a Measurement Tool for an Organic Rankine Cycle Micro-Turbogenerator10.1016/j.measurement.2020.107666 ↗
34. A Review on Health Monitoring of Concrete Structures Using Embedded Piezoelectric Sensor10.1016/j.conbuildmat.2023.133179 ↗
35. Lei, Y.-J., Li, R.-J., Zhang, L.-S., Hu, P.-H., and Huang, Q.-X. (2022). Optical Accelerometers for Detecting Low-Frequency Micro-Vibrations. Appl. Sci., 12.10.3390/app12083994 ↗
36. Lee, H., Oh, M., Seo, J., and Kim, W. (2021). Seismic and Energy Performance Evaluation of Large-Scale Curtain Walls Subjected to Displacement Control Fasteners. Appl. Sci., 11.10.3390/app11156725 ↗
37. Aiello, C. (2019, January 24–26). In-Plane Seismic Response of a Glazed Curtain Wall: Full-Scale Laboratory Test and Non-Linear Modelling. Proceedings of the 7th International Conference on Computational Methods in Structural Dynamics and Earthquake Engineering (COMPDYN 2019), Crete, Greece.10.7712/120119.6918.19258 ↗
38. (2016). Curtain Walling—Impact Resistance—Performance Requirements. Standard No. EN 14019:2016. Available online: https://standards.iteh.ai/catalog/standards/cen/1bfe4fa0-6bf4-4ae7-b2a2-0a87ced89e0d/en-14019-2016.
39. (2024, February 09). La Norma Uni En 12600: Prova Del Pendolo–Metodo Della Prova Di Impatto E Classificazione Per Il Vetro Piano. Available online: https://www.ingenio-web.it/files/guida-alle-norme-tecniche-del-vetro-per-edilizia.pdf.
40. (2024, March 13). NI-9234 Specifications—NI. Available online: https://www.ni.com/docs/en-US/bundle/ni-9234-specs/page/specs.html.
41. HBK (Hottinger, Brüel & Kjær) (2024, February 09). QuantumX MX840B Universal Amplifier. Available online: https://www.hbm.com/en/2129/quantumx-mx840b-8-channel-universal-amplifier/?product_type_no=QuantumX%20MX840B/MX440B:%20Universal%20Data%20Acquisition%20Module.
42. (2003). Facciate Continue Permeabilità All’aria Requisiti Prestazionali e Classificazione. Standard No. UNI BS EN 12152_2002.
43. (2002). Facciate continue-Permeabilità all’aria-Metodo Di Prova. Standard No. UNI EN 12153:2002.
44. (1999). Curtain Walling—Watertighness-Performance Requirments and Classification. Standard No. UNI BS EN 12154_1999.
45. (2002). Facciate Continue-Tenuta All’acqua-Prova Di Laboratorio Sotto Pressione Statica. Standard No. UNI EN 12155:2002.
46. (2002). Facciate Continue-Resistenza al Carico Del Vento-Metodo Di Prova. Standard No. UNI EN 12179:2002.