Development and Initial Characterisation of a Localised Elastin Degradation Ex Vivo Porcine Aortic Aneurysm Model
Source abstract
Abstract
Aortic aneurysms (AA) occur in 4.8% of people causing 150,000 deaths annually. While endovascular aneurysm repairs reduce surgical morbidity, device-related failures (leak/displacement) are frequent highlighting the need for test models that better represent the mural geometry and compliance changes in human AAs. We aimed to develop and characterise an ex vivo porcine aortic model of AA. The optimal duration of tissue elastase exposure to emulate AA changes in elastin microstructure and content was determined using porcine aortic rings. Elastase-induced changes were quantified morphologically, and mechanical properties assessed via ring tensile testing. Subsequent experiments tested the potential for localised elastase treatment in a 1 cm segment of porcine aorta using a specially designed 3D printed rig. The effect on pressure-diameter behaviour was investigated via inflation-extension testing. Elastase treatment produced time dependent decreases in elastin, resulting in an increased tensile modulus and circumferential length in the ring samples in the final phase of the J-shaped tissue stress-strain curves. In whole aortic segments, localised elastase-induced luminal degradation was successfully limited to a central region. The degree of elastin degradation achieved was sufficient to cause localised dilation with respect to controls under physiological pressures. Localised elastin degradation in porcine aortic segments is feasible and emulates the changes seen clinically in aortic aneurysms.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Aortic aneurysm repair treatments · Aortic Disease and Treatment Approaches · Cardiac, Anesthesia and Surgical Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, D02 R590 Dublin, Ireland
Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, D02 R590 Dublin, Ireland
Advanced Materials and Bioengineering Research Centre (AMBER), Royal College of Surgeons in Ireland and Trinity College Dublin, D02 W05 Dublin, Ireland
Funding
European Research Council (ERC)
References (65)
Show source-provided references
1. Tse, H.-F., Lip, G.Y., and Coats, A.J.S. (2011). Cardiology (Oxford Desk Reference), Oxford University Press.10.1093/med/9780199568093.001.0001 ↗
2. Li, X., Zhao, G., Zhang, J., Duan, Z., and Xin, S. (2013). Prevalence and Trends of the Abdominal Aortic Aneurysms Epidemic in General Population—A Meta-Analysis. PLoS ONE, 8.10.1371/journal.pone.0081260 ↗
3. Global Burden of Aortic Aneurysm and Attributable Risk Factors from 1990 to 201710.5334/gh.920 ↗
4. Meta-analysis of individual-patient data from EVAR-1, DREAM, OVER and ACE trials comparing outcomes of endovascular or open repair for abdominal aortic aneurysm over 5 years10.1002/bjs.10430 ↗
5. Changes in abdominal aortic aneurysm epidemiology10.23736/S0021-9509.17.10064-9 ↗
6. A comparison of endovascular versus open repair for ruptured abdominal aortic aneurysm—Meta-analysis of propensity score-matched data10.1177/17085381211025168 ↗
7. Complications of endovascular aneurysm repair of the thoracic and abdominal aorta: Evaluation and management10.21037/cdt.2017.09.17 ↗
8. ACC/AHA 2005 Practice Guidelines for the management of patients with peripheral arterial disease (lower extremity, renal, mesenteric, and abdominal aortic): A collaborative report from the American Association for Vascular Surgery/Society for Vascular Surgery, Society for Cardiovascular Angiography and Interventions, Society for Vascular Medicine and Biology, Society of Interventional Radiology, and the ACC/AHA Task Force on Practice Guidelines (Writing Committee to Develop Guidelines for the Management of Patients With Peripheral Arterial Disease): Endorsed by the American Association of Cardiovascular and Pulmonary Rehabilitation; National Heart, Lung, and Blood Institute; Society for Vascular Nursing; TransAtlantic Inter-Society Consensus; and Vascular Disease Foundation10.1161/CIRCULATIONAHA.106.174526 ↗
9. The relevance of aortic endograft prosthetic infection10.1016/j.jvs.2010.12.067 ↗
10. Five-year results of endovascular treatment with the Gore TAG device compared with open repair of thoracic aortic aneurysms10.1016/j.jvs.2007.12.006 ↗
11. The “first generation” of endovascular stent-grafts for patients with aneurysms of the descending thoracic aorta10.1016/S0022-5223(98)00455-3 ↗
12. Update: Complications and management of infrarenal EVAR10.1016/j.ejrad.2008.05.015 ↗
13. Endovascular stent grafting versus open surgical repair of descending thoracic aortic aneurysms in low-risk patients: A multicenter comparative trial10.1016/j.jtcvs.2006.07.040 ↗
14. Need for secondary interventions after endovascular repair of abdominal aortic aneurysms. Intermediate-term follow-up results of a European collaborative registry (EUROSTAR)10.1046/j.1365-2168.2000.01661.x ↗
15. Patient-specific computational modeling of endovascular aneurysm repair: State of the art and future directions10.1002/cnm.3529 ↗
16. The reason for the shape of the distensibility curves of arteries10.1139/y57-080 ↗
17. Ascending thoracic aortic aneurysms are associated with compositional remodeling and vessel stiffening but not weakening in age-matched subjects10.1016/j.jtcvs.2008.07.023 ↗
18. The composition and mechanical properties of abdominal aortic aneurysms10.1016/0741-5214(94)90169-4 ↗
19. Recent Advances in Biomechanical Characterization of Thoracic Aortic Aneurysms10.3389/fcvm.2020.00075 ↗
20. A compliant aortic model for in vitro simulations: Design and manufacturing process10.1016/j.medengphy.2018.04.022 ↗
21. Biomechanical behavior of the arterial wall and its numerical characterization10.1016/S0010-4825(98)00022-5 ↗
22. Arterial extracellular matrix: A mechanobiological study of the contributions and interactions of elastin and collagen10.1016/j.bpj.2014.05.014 ↗
23. The effects of aneurysm on the biaxial mechanical behavior of human abdominal aorta10.1016/j.jbiomech.2005.03.003 ↗
24. Biomechanical response of ascending thoracic aortic aneurysms: Association with structural remodelling10.1080/10255842.2010.522186 ↗
25. Experimental Study of a Novel Suture-less Aortic Anastomotic Device10.1016/j.ejvs.2007.02.004 ↗
26. Additive fabrication technologies applied to medicine and health care: A review10.1007/s00170-007-1308-1 ↗
27. Stent-Graft Deployment Increases Aortic Stiffness in an Ex Vivo Porcine Model10.1016/j.avsg.2017.04.024 ↗
28. Impact of thoracic endovascular aortic repair on radial strain in an ex vivo porcine model
29. An experimental investigation of the impact of thoracic endovascular aortic repair on longitudinal strain10.1093/ejcts/ezw180 ↗
30. de Beaufort, H.W.L., Coda, M., Conti, M., van Bakel, T.M.J., Nauta, F.J.H., Lanzarone, E., Moll, F.L., van Herwaarden, J.A., Auricchio, F., and Trimarchi, S. (2017). Changes in aortic pulse wave velocity of four thoracic aortic stent grafts in an ex vivo porcine model. PLoS ONE, 12.10.1371/journal.pone.0186080 ↗
31. Comparative Analysis of Porcine and Human Thoracic Aortic Stiffness10.1016/j.ejvs.2017.12.014 ↗
32. Development of an Endovascular Training Model for Simulation of Evar Procedures Using 3D Rapid Prototyping for the Production of Exchangeable Patient Specific Anatomic Models10.1016/j.ejvs.2019.06.896 ↗
33. Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing10.1186/1532-429X-15-2 ↗
34. 3D Reconstruction and Manufacture of Real Abdominal Aortic Aneurysms: From CT Scan to Silicone Model10.1115/1.2907765 ↗
35. In vitro non-rigid life-size model of aortic arch aneurysm for endovascular prosthesis assessment10.1016/j.ejcts.2007.10.016 ↗
36. A Protocol for a Novel Human Ex Vivo Model of Aneurysm10.1016/j.xpro.2020.100108 ↗
37. Development and characterisation of a human ex-vivo model of aneurysm10.1016/j.atherosclerosis.2018.06.425 ↗
38. An in vitro method to keep human aortic tissue sections functionally and structurally intact10.1038/s41598-018-26549-4 ↗
39. Failure of Elastin or Collagen as Possible Critical Connective Tissue Alterations Underlying Aneurysmal Dilatation10.1177/096721099400200412 ↗
40. The effect of proteolytic treatment on plastic deformation of porcine aortic tissue10.1016/j.jmbbm.2008.04.001 ↗
41. Progressive structural and biomechanical changes in elastin degraded aorta10.1007/s10237-012-0404-9 ↗
42. Full-field strain mapping of healthy and pathological mouse aortas using stereo digital image correlation10.1016/j.jmbbm.2023.105745 ↗
43. Rapid saccular aneurysm induction by elastase application in vitro10.1097/00006123-199707000-00034 ↗
44. Animal models in the research of abdominal aortic aneurysms development10.33549/physiolres.933579 ↗
45. Mouse models of abdominal aortic aneurysms10.1161/01.ATV.0000118013.72016.ea ↗
46. Diffusion tensor imaging and arterial tissue: Establishing the influence of arterial tissue microstructure on fractional anisotropy, mean diffusivity and tractography10.1038/s41598-020-77675-x ↗
47. NIH Image to ImageJ: 25 years of image analysis10.1038/nmeth.2089 ↗
48. Methods in Mechanical Testing of Arterial Tissue: A Review10.1111/str.12183 ↗
49. Investigation of a small-diameter decellularised artery as a potential scaffold for vascular tissue engineering; biomechanical evaluation and preliminary cell seeding10.1016/j.jmbbm.2012.06.001 ↗
50. Circumferential variations of mechanical behavior of the porcine thoracic aorta during the inflation test10.1016/j.jbiomech.2011.04.022 ↗
51. Identification of the material parameters of an aortic wall
52. Quantification of histochemical staining by color deconvolution
53. Effect of elastin degradation on carotid wall mechanics as assessed by a constituent-based biomechanical model10.1152/ajpheart.01108.2006 ↗
54. Passive mechanics and connective tissue composition of canine arteries
55. In-situ characterization of the uncrimping process of arterial collagen fibers using two-photon confocal microscopy and digital image correlation10.1016/j.jbiomech.2013.08.001 ↗
56. Biomechanical evaluation of ascending aortic aneurysms10.1155/2014/820385 ↗
57. Effect of aneurysm on the tensile strength and biomechanical behavior of the ascending thoracic aorta10.1016/S0003-4975(02)04711-2 ↗
58. Epidemiology and management of aortic disease: Aortic aneurysms and acute aortic syndromes10.1038/s41569-020-00472-6 ↗
59. Thoracic and Abdominal Aortic Aneurysms10.1161/01.CIR.0000154569.08857.7A ↗
60. Characterization of Biaxial Mechanical Behavior of Porcine Aorta under Gradual Elastin Degradation10.1007/s10439-012-0733-y ↗
61. Measuring Areas (2023, April 25). Read the Docs—QuPath 2.3 Documentation 2021. Available online: https://qupath.readthedocs.io/en/0.2/docs/tutorials/measuring_areas.html.
62. Quantitative not qualitative histology differentiates aneurysmal from nondilated ascending aortas and reveals a net gain of medial components10.1038/s41598-021-92659-1 ↗
63. The Ring-Pull Assay for Mechanical Properties of Fibrous Soft Tissues—An Analysis of the Uniaxial Approximation and a Correction for Nonlinear Thick-Walled Tissues10.1007/s11340-020-00623-3 ↗
64. On the Uniaxial Ring Test of Tissue Engineered Constructs10.1007/s11340-014-9910-2 ↗
65. Conti, M. (2019, January 20–21). Biomechanical simulations and 3D printing for endovascular device testing. Proceedings of the Meeting Annuale Centro 3R—GENOVA, Giugno 2019, Genoa, Italy.10.4081/bse.2019.86 ↗