journal article·2023-03-21Open access

Bone Cut Accuracy in Total Knee Arthroplasty: Do Conventional Cutting Guides Stay True to the Planned Coronal Orientation of the Components?

Joan Leal-Blanquet, Pedro Hinarejos, Elisenda Gimenez-Valero, Raul Torres-Claramunt, Juan Sánchez-Soler, Juan Erquicia, Sergi Gil-González, Angela Zumel-Marne, Juan Carlos Monllau

Applied Sciences· Volume 13· Issue 6

Abstract

Background: Total knee arthroplasty (TKA) has become the gold standard for the definitive treatment of knee osteoarthritis. One crucial aspect in the implantation of a TKA is the precise orientation of the femoral and tibial components. The main purpose of the present study is to assess, in patients undergoing total knee replacement, whether the difference between the planned angulation in the distal femoral cut and the angulation obtained in the postoperative radiological control is low enough to consider the conventional bone-cutting guides reliable. Methods: A retrospective study was designed with a consecutive series of patients who had undergone primary total knee arthroplasty using conventional instrumentation over one year. The authors analysed the main variable (bone cuts) while considering different variables (age, gender, surgeon, prosthesis, laterality, constraint, body mass index and alignment) to identify different patient patterns that justify the results in the main variable. Descriptive variables were analysed using the Mann–Whitney U and Kruskal–Wallis tests. Additionally, the correlation between continuous variables was explored in accordance with the Spearman correlation. Results: A total of 340 patients with a mean age of 75 ± 9.16 years were finally included in the present study. The mean absolute error of the main variable for the femoral coronal bone cut was 1.89° (SD 1.53). For the tibial coronal bone cut, it was 1.31° (SD 2.54). These values correspond to what remains after subtracting the radiological angulation obtained in the postoperative period from the planned intraoperative angulation of the distal femoral cut. No associations were observed between the main variable (the angulation of the proximal tibial cut and distal femoral cut) and the rest of variables for either the femur or tibia. Conclusion: A discrepancy between the planned angulation and the final radiological measure on the coronal plane of the femur and tibia using conventional cutting guides has been demonstrated. The degree of deviation is low enough that it probably does not affect clinical outcomes. Therefore, the use of conventional cutting guides will continue to be an appropriate tool to perform bone cuts in knee replacement surgery.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Total Knee Arthroplasty Outcomes · Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Orthopedic Surgery, Hospital d’Igualada, Consorci Sanitari de L’Anoia, 08700 Barcelona, Spain

Fundació Sanitària d’Igualada, 08700 Barcelona, Spain

Department of Orthopedic Surgery, Parc de Salut Mar, Hospital de l’Esperança, 08024 Barcelona, Spain

Facultat de Medicina, Universitat Autonoma de Barcelona, 08193 Barcelona, Spain

Department of Orthopedic Surgery, Fundació Althaia, 08243 Barcelona, Spain

Grupo de Investigación en Salud Pública, Universidad de Alicante, 03690 Alicante, Spain

References (39)

Show source-provided references
1. Obesity, Bariatric Surgery, and Hip/Knee Arthroplasty Outcomes10.1016/j.suc.2020.12.011 ↗
2. The Effects of a New Protocol on Blood Loss in Total Knee Arthroplasty10.52965/001c.37625 ↗
3. Critical Steps in Total Knee Arthroplasty. A Method of Analyzing Operative Procedures10.1007/BF00181105 ↗
4. Knee Arthroplasty System with Medialized Keel: Seven-Year Follow-up of a Pioneer Cohort10.1016/j.knee.2020.04.014 ↗
5. Current Failure Mechanisms after Knee Arthroplasty Have Changed: Polyethylene Wear Is Less Common in Revision Surgery10.2106/JBJS.M.01534 ↗
6. Positioning of Total Knee Arthroplasty with and without Navigation Support. A Prospective, Randomised Study10.1302/0301-620X.85B6.13722 ↗
7. The Effect of Alignment and BMI on Failure of Total Knee Replacement10.2106/JBJS.J.00772 ↗
8. Do Manual Cutting Guides for Total Knee Arthroplasty Introduce Systematic Error?10.1007/s00264-015-2963-8 ↗
9. Improved Accuracy of Component Alignment with the Implementation of Image-Free Navigation in Total Knee Arthroplasty10.1007/s00167-007-0420-y ↗
10. Computer Navigation versus Standard Instrumentation for TKA: A Single-Surgeon Experience10.1097/01.blo.0000186561.70566.95 ↗
11. Comparison of Planned and Achieved Implant Position in Total Knee Arthroplasty with Patient-Specific Positioning Guides10.3109/17453674.2014.985154 ↗
12. Quantification of Effect of Sequential Posteromedial Release on Flexion and Extension Gaps: A Computer-Assisted Study in Cadaveric Knees10.1016/j.arth.2008.03.018 ↗
13. Computer-Assisted Navigation Increases Precision of Component Placement in Total Knee Arthroplasty10.1097/01.blo.0000150564.31880.c4 ↗
14. A Comparison of Patient-Specific and Conventional Instrumentation for Total Knee Arthroplasty: A Multicentre Randomised Controlled Trial10.1302/0301-620X.97B1.34440 ↗
15. Postoperative Coronal Alignment after Total Knee Arthroplasty: Does Tailoring the Femoral Valgus Cut Angle Really Matter?10.1016/j.arth.2015.03.013 ↗
16. Radiological Assessment of Osteo-Arthrosis10.1136/ard.16.4.494 ↗
17. Radiological Assessment of Lower Limb Alignment10.1302/2058-5241.6.210015 ↗
18. The Effect of Post-Operative Mechanical Axis Alignment on the Survival of Primary Total Knee Replacements after a Follow-up of 15 Years10.1302/0301-620X.93B9.26573 ↗
19. Effect of Postoperative Mechanical Axis Alignment on the Fifteen-Year Survival of Modern, Cemented Total Knee Replacements10.2106/JBJS.I.01398 ↗
20. Accuracy of Empirical Distal Femoral Valgus Cut Angle of 4° to 6° in Total Knee Arthroplasty: A Randomized Controlled Trial10.1007/s00590-021-02890-9 ↗
21. Femoral Shaft Bowing in the Coronal Plane Has More Significant Effect on the Coronal Alignment of TKA than Proximal or Distal Variations of Femoral Shape10.1007/s00167-014-3006-5 ↗
22. Cement Mantle Thickness at the Bone Cement Interface in Total Knee Arthroplasty: Comparison of PS150 RP and LPS-Flex Knee Implants10.5792/ksrr.16.013 ↗
23. Interobserver Reliability and Intraobserver Reproducibility of Powers Ratio for Assessment of Atlanto-Occipital Junction: Comparison of Plain Radiography and Computed Tomography10.1007/s00586-008-0877-5 ↗
24. Inter-Observer and Intra-Observer Reliability of Mechanical Axis Alignment before and after Total Knee Arthroplasty Using Long Leg Radiographs10.1016/j.knee.2015.11.013 ↗
25. Patient-Specific Positioning Guides for Total Knee Arthroplasty: No Significant Difference between Final Component Alignment and Pre-Operative Digital Plan except for Tibial Rotation10.1007/s00167-015-3661-1 ↗
26. Optimizing Limb Position for Measuring Knee Anatomical Axis Alignment from Standing Knee Radiographs10.3899/jrheum.080732 ↗
27. Do Small Changes in Rotation Affect Measurements of Lower Extremity Limb Alignment?10.1186/s13018-017-0571-6 ↗
28. Does Obesity Affect Clinical and Radiological Outcomes in Minimally Invasive Total Knee Arthroplasty? Minimum 5-Year Follow-up of Minimally Invasive TKA in Obese Patients10.4055/cios.2018.10.3.315 ↗
29. No Effect of Obesity on Limb and Component Alignment after Computer-Assisted Total Knee Arthroplasty10.1016/j.knee.2014.04.004 ↗
30. Computed Tomography-Based Patient-Specific Instrumentation Loses Accuracy with Significant Varus Preoperative Misalignment
31. Assessing the Accuracy of Patient-Specific Guides for Total Knee Arthroplasty10.1007/s00167-014-3429-z ↗
32. The Accuracy of Bony Resection from Patient-Specific Guides during Total Knee Arthroplasty10.1007/s00167-016-4254-3 ↗
33. A Prospective Randomised Controlled Study of Patient-Specific Cutting Guides Compared with Conventional Instrumentation in Total Knee Replacement10.1302/0301-620X.95B3.29903 ↗
34. Intraoperative Validation of Bone Cut Accuracy of a Pinless Smart Touch-Screen Navigation System Device in Total Knee Arthroplasty10.1002/rcs.2030 ↗
35. Accelerometer-Based and Computer-Assisted Navigation in Total Knee Arthroplasty: A Reduction in Mechanical Axis Outliers Does Not Lead to Improvement in Functional Outcomes or Quality of Life When Compared to Conventional Total Knee Arthroplasty10.1016/j.arth.2017.09.005 ↗
36. Accuracy of a New Robotically Assisted Technique for Total Knee Arthroplasty: A Cadaveric Study10.1016/j.arth.2019.06.040 ↗
37. Robotic-Arm Assisted Total Knee Arthroplasty Demonstrated Greater Accuracy and Precision to Plan Compared with Manual Techniques10.1055/s-0038-1641729 ↗
38. Accuracy of Bone Resection in MAKO Total Knee Robotic-Assisted Surgery10.1055/s-0039-1700570 ↗
39. Are There Differences in Accuracy or Outcomes Scores Among Navigated, Robotic, Patient-Specific Instruments or Standard Cutting Guides in TKA? A Network Meta-Analysis10.1097/CORR.0000000000001324 ↗