Show source-provided references
1. Modification of the Oxygen Effect when Bacteria are given Large Pulses of Radiation
10.1038/1831450a0 ↗3. The Constant Low Oxygen Concentration in All the Target Cells for Mouse Tail Radionecrosis
10.2307/3575852 ↗7. Hypofractionated FLASH-RT as an Effective Treatment against Glioblastoma that Reduces Neurocognitive Side Effects in Mice
10.1158/1078-0432.CCR-20-0894 ↗8. Ultra-high-dose-rate FLASH and Conventional-Dose-Rate Irradiation Differentially Affect Human Acute Lymphoblastic Leukemia and Normal Hematopoiesis
10.1016/j.ijrobp.2020.10.012 ↗9. Reduced cognitive deficits after FLASH irradiation of whole mouse brain are associated with less hippocampal dendritic spine loss and neuroinflammation
12. Ultra-high dose rate electron beams and the FLASH effect: From preclinical evidence to a new radiotherapy paradigm
10.1002/mp.15442 ↗14. Lin, B., Gao, F., Yang, Y., Wu, D., Zhang, Y., Feng, G., Dai, T., and Du, X. (2021). FLASH Radiotherapy: History and Future. Front. Oncol., 11.
10.3389/fonc.2021.644400 ↗15. DesRosiers, C., Moskvin, V., Bielajew, A.F., and Papiez, L. (2000). 150–250 MeV Electron Beams in Radiation Therapy. Phys. Med. Biol., 45.
10.1088/0031-9155/45/7/306 ↗16. Sarti, A., De Maria, P., Battistoni, G., De Simoni, M., Di Felice, C., Dong, Y., Fischetti, M., Franciosini, G., Marafini, M., and Marampon, F. (2021). Deep Seated Tumour Treatments With Electrons of High Energy Delivered at FLASH Rates: The Example of Prostate Cancer. Front. Oncol., 11.
10.3389/fonc.2021.777852 ↗17. Characteristics of very high-energy electron beams for the irradiation of deep-seated targets
10.1002/mp.14891 ↗18. Ronga, M.G., Cavallone, M., Patriarca, A., Leite, A.M., Loap, P., Favaudon, V., Créhange, G., and De Marzi, L. (2021). Back to the Future: Very High-Energy Electrons (VHEEs) and Their Potential Application in Radiation Therapy. Cancers, 13.
10.3390/cancers13194942 ↗19. Treatment planning for radiotherapy with very high-energy electron beams and comparison of VHEE and VMAT plans
10.1118/1.4918923 ↗21. Corsini, R., Aksoy, A., Farabolini, W., Gilardi, A., Malyzhenkov, A., Bateman, J., Dosanjh, M., Korysko, P., Robertson, C., and Rieker, V. (2024, January 25–30). Medical activites in CLEAR: Studies towards radiotherapy using very high energy electrons (VHEE) in the FLSH regime. Proceedings of the LINAC2024, Chicago, IL, USA.
22. Burkart, F., Aßmann, R., Dinter, H., Jaster-Merz, S., Kuropka, W., Mayet, F., and Vinatier, T. (September, January 28). The ARES Linac at DESY. Proceedings of the 31st International Linear Accelerator Conference, LINAC2022, Liverpool, UK.
23. Subiel, A., Moskvin, V., Welsh, G.H., Cipiccia, S., Reboredo, D., Evans, P., Partridge, M., DesRosiers, C., Anania, M.P., and Cianchi, A. (2014). Dosimetry of Very High Energy Electrons (VHEE) for Radiotherapy Applications: Using Radiochromic Film Measurements and Monte Carlo Simulations. Phys. Med. Biol., 59.
10.1088/0031-9155/59/19/5811 ↗24. Comparison of Film Measurements and Monte Carlo Simulations of Dose Delivered with Very High-Energy Electron Beams in a Polystyrene Phantom
10.1118/1.4914371 ↗26. Technical note: Validation of an ultrahigh dose rate pulsed electron beam monitoring system using a current transformer for FLASH preclinical studies
10.1002/mp.15474 ↗27. Jain, S., Cetnar, A., Woollard, J., Gupta, N., Blakaj, D., Chakravarti, A., and Ayan, A.S. (2023). Pulse parameter optimizer: An efficient tool for achieving prescribed dose and dose rate with electron FLASH platforms. Phys. Med. Biol., 68.
10.1088/1361-6560/acf63e ↗28. Cayley, J., Paino, J., Guatelli, S., Rosenfeld, A., Lerch, M., and Tan, Y.R.E. (2024). Simulation and commissioning of a Faraday cup for absolute charge measurements of very high-energy electrons in-air at PEER. Front. Phys., 12.
10.3389/fphy.2024.1448025 ↗29. All Irradiations that are Ultra-High Dose Rate may not be FLASH: The Critical Importance of Beam Parameter Characterization and In Vivo Validation of the FLASH Effect
10.1667/RADE-20-00141.1 ↗30. Bateman, J.J., Buchanan, E., Corsini, R., Farabolini, W., Korysko, P., Garbrecht Larsen, R., Malyzhenkov, A., Ortega Ruiz, I., Rieker, V., and Gerbershagen, A. (2024). Development of a novel fibre optic beam profile and dose monitor for very high energy electron radiotherapy at ultrahigh dose rates. Phys. Med. Biol., 69.
10.1088/1361-6560/ad33a0 ↗31. Clements, N., Esplen, N., Bateman, J., Robertson, C., Dosanjh, M., Korysko, P., Farabolini, W., Corsini, R., and Bazalova-Carter, M. (2024). Mini-GRID radiotherapy on the CLEAR very-high-energy electron beamline: Collimator optimization, film dosimetry, and Monte Carlo simulations. Phys. Med. Biol., 69.
10.1088/1361-6560/ad247d ↗32. Multi-Institutional Audit of FLASH and Conventional Dosimetry With a 3D Printed Anatomically Realistic Mouse Phantom
10.1016/j.ijrobp.2024.03.017 ↗34. Kranzer, R., Schüller, A., Bourgouin, A., Hackel, T., Poppinga, D., Lapp, M., Looe, H.K., and Poppe, B. (2022). Response of diamond detectors in ultra-high dose-per-pulse electron beams for dosimetry at FLASH radiotherapy. Phys. Med. Biol., 67.
10.1088/1361-6560/ac594e ↗35. Development of an ultra-thin parallel plate ionization chamber for dosimetry in FLASH radiotherapy
10.1002/mp.15668 ↗36. Di Martino, F., Barca, P., Barone, S., Bortoli, E., Borgheresi, R., De Stefano, S., Di Francesco, M., Faillace, L., Giuliano, L., and Grasso, L. (2020). FLASH Radiotherapy With Electrons: Issues Related to the Production, Monitoring, and Dosimetric Characterization of the Beam. Front. Phys., 8.
10.3389/fphy.2020.570697 ↗37. Ion recombination correction for very high dose-per-pulse high-energy electron beams
10.1118/1.1940167 ↗38. Using laboratory X-ray and cobalt-60 irradiations to predict CMOS device response in strategic and space environments
10.1109/23.25487 ↗41. Choi, J.H., Cutajar, D., Metcalfe, P., and Downes, S. (2018). Application of MOSkin detector for in vivo dosimetry on total skin electron therapy (TSET). Biomed. Phys. Eng. Express, 4.
10.1088/2057-1976/aaac61 ↗43. Characterization of MOSkin detector for in vivo skin dose measurement during megavoltage radiotherapy
46. Tai, M., Patterson, E., Metcalfe, P.E., Rosenfeld, A., and Oborn, B.M. (2022). Skin Dose Modeling and Measurement in a High Field In-Line MRI-Linac System. Front. Phys., 10.
10.3389/fphy.2022.902744 ↗47. A comparison of entrance skin dose delivered by clinical angiographic c-arms using the real-time dosimeter: The MOSkin
10.1007/s13246-016-0435-0 ↗48. Monte Carlo study of the energy response and depth dose water equivalence of the MOSkin radiation dosimeter at clinical kilovoltage photon energies
10.1007/s13246-011-0075-3 ↗51. (2025, February 03). Council Directive 2013/59/Euratom of 5 December 2013 Laying Down Basic Safety Standards for Protection Against the Dangers Arising from Exposure to Ionising Radiation, and Repealing Directives 89/618/Euratom, 90/641/Euratom, 96/29/Euratom, 97/43/Euratom and 2003/122/Euratom. Available online: http://data.europa.eu/eli/dir/2013/59/oj/eng.
52. Characterization of a MOSkin detector for in vivo skin dose measurements during interventional radiology procedures
10.1118/1.4918576 ↗53. Clinical application of MOSkin dosimeters to rectal wall in vivo dosimetry in gynecological HDR brachytherapy
10.1016/j.ejmp.2017.05.003 ↗54. SU-F-T-328: Real-Time in Vivo Dosimetry of Prostate SBRT Boost Treatments Using MOSkin Detectors
10.1118/1.4956513 ↗55. Towards real time in-vivo rectal dosimetry during trans-rectal ultrasound based high dose rate prostate brachytherapy using MOSkin dosimeters
10.1016/j.radonc.2020.08.003 ↗57. Radioluminescence characterization of in situ x-ray nanodosimeters: Potential real-time monitors and modulators of external beam radiation therapy
10.1063/1.4900962 ↗58. Cayley, J., Tan, Y.R.E., Petasecca, M., Cutajar, D., Breslin, T., Rosenfeld, A., and Lerch, M. (2024). MOSkin dosimetry for an ultra-high dose-rate, very high-energy electron irradiation environment at PEER. Front. Phys., 12.
10.3389/fphy.2024.1401834 ↗59. Gafchromic EBT3 Film Provides Equivalent Dosimetric Performance to EBT-XD Film for Stereotactic Radiosurgery Dosimetry
10.1007/s13246-024-01430-z ↗61. Ashland (2024, May 12). Ashland EBT-XD Datasheet. Available online: https://www.ashland.com/file_source/Ashland/Documents/PHA21-011_Gafchromic%20EBT-XD%20Protocol.pdf.
62. Wanstall, H.C., Korysko, P., Farabolini, W., Corsini, R., Bateman, J.J., Rieker, V., Hemming, A., Henthorn, N.T., Merchant, M.J., and Santina, E. (2024). VHEE FLASH sparing effect measured at CLEAR, CERN with DNA damage of pBR322 plasmid as a biological endpoint. Sci. Rep., 14.
10.1038/s41598-024-65055-8 ↗63. Whitmore, L., Mackay, R.I., van Herk, M., Korysko, P., Farabolini, W., Malyzhenkov, A., Corsini, R., and Jones, R.M. (2024). CERN-based experiments and Monte-Carlo studies on focused dose delivery with very high energy electron (VHEE) beams for radiotherapy applications. Sci. Rep., 14.
10.1038/s41598-024-60997-5 ↗64. Influence of heterogeneous media on Very High Energy Electron (VHEE) dose penetration and a Monte Carlo-based comparison with existing radiotherapy modalities
10.1016/j.nimb.2020.09.008 ↗65. Small, K.L., Henthorn, N.T., Angal-Kalinin, D., Chadwick, A.L., Santina, E., Aitkenhead, A., Kirkby, K.J., Smith, R.J., Surman, M., and Jones, J. (2021). Evaluating very high energy electron RBE from nanodosimetric pBR322 plasmid DNA damage. Sci. Rep., 11.
10.1038/s41598-021-82772-6 ↗66. Application of a Novel Diamond Detector for Commissioning of FLASH Radiotherapy Electron Beams
10.1002/mp.15782 ↗67. Bourgouin, A., Schüller, A., Hackel, T., Kranzer, R., Poppinga, D., Kapsch, R.P., and McEwen, M. (2020). Calorimeter for Real-Time Dosimetry of Pulsed Ultra-High Dose Rate Electron Beams. Front. Phys., 8.
10.3389/fphy.2020.567340 ↗68. Medina, E., Ferro, A., Abujami, M., Camperi, A., Centis Vignali, M., Data, E., Del Sarto, D., Deut, U., Di Martino, F., and Fadavi Mazinani, M. (2024). First Experimental Validation of Silicon-Based Sensors for Monitoring Ultra-High Dose Rate Electron Beams. Front. Phys., 12.
10.3389/fphy.2024.1258832 ↗69. Technical note: Proton beam dosimetry at ultra-high dose rates (FLASH): Evaluation of GAFchromic™ (EBT3, EBT-XD) and OrthoChromic (OC-1) film performances
10.1002/mp.15526 ↗70. Del Sarto, D., Masturzo, L., Cavalieri, A., Celentano, M., Fuentes, T., Gadducci, G., Giannini, N., Gonnelli, A., Milluzzo, G., and Paiar, F. (2025). A systematic investigation on the response of EBT-XD gafchromic films to varying dose-per-pulse, average dose-rate and instantaneous dose-rate in electron flash beams. Front. Phys., 13.
10.3389/fphy.2025.1474416 ↗72. Oldham, T.R. (2012). Basic Mechanisms of TID and DDD Response in MOS and Bipolar Microelectronics.
73. Ma, T., and Dressendorfer, P. (1989). Ionizing Radiation Effects in MOS Devices and Circuits, John Wiley and Sons Inc.. INIS Reference Number: 21087484.
74. Absolute depth-dose-rate measurements for an 192Ir HDR brachytherapy source in water using MOSFET detectors
10.1118/1.2198168 ↗75. Kattner, K. (1988). Modelling the effects of heavy charged particles on MOSFETs. Air Force Inst. Technol.
76. Ausman, G. (1987). Field Dependence of Geminate Recombination in a Dielectric Medium, Defense Technical Information Center.
79. The International Commission on Radiation Units and Measurements (ICRU) (1984). Stopping Powers for Electrons and Positrons, ICRU. Technical Report 0-913394-31-9—ICRU–37 INIS Reference Number: 24031395.
81. NIST (2024, June 27). NIST E-Star Database, Available online: https://physics.nist.gov/PhysRefData/Star/Text/ESTAR.html.
85. Technical note: Energy dependence of the Gafchromic EBT4 film: Dose-response curves for 70 kV, 6 MV, 6 MV FFF, 10 MV FFF, and 15 MV x-ray beams
10.1002/mp.16240 ↗87. Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group
10.1002/mp.14226 ↗89. High Spatial Resolution Dosimetry for Radiation Oncology with “MagicPlates”, a New 976-pixel Monolithic Silicon Detector
10.1002/acm2.70015 ↗