Designing Intensive Care Unit Windows in a Mediterranean Climate: Efficiency, Daylighting, and Circadian Response
Source abstract
Abstract
Hospital intensive care units (ICUs) frequently experience inadequate lighting conditions, with low daytime and excessive nighttime illuminance, which can negatively affect patient recovery and the work performance of health personnel. This study examines the impact of window design parameters—specifically, window-to-wall ratio (WWR) and window position—and interior surface reflectance on visual comfort, lighting performance, energy consumption, and human well-being in intensive care units (ICUs) in Mediterranean climates, according to orientation. Using dynamic lighting metrics, such as daylight autonomy (DA) and circadian stimulus autonomy (CSA), this research quantifies the influence of these design factors. The results suggest that a WWR of 25% is optimal for achieving sufficient DA and CSA values, with centered window configurations preferred for uniform daylight distribution and circadian stimulus. This study further emphasizes the significance of interior reflectance, recommending bright coatings to maximize outcomes, while advising against dark finishes, particularly in north-facing rooms or with smaller WWRs. Although Seville shows slightly better performance than Barcelona, the proposed configurations are effective across both locations, highlighting the prioritization of window sizing, positioning, and reflectance over Mediterranean geographical differences. These findings offer practical guidance for ICU design to enhance natural lighting, supporting patient recovery and overall well-being through improved circadian alignment.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Circadian rhythm and melatonin · Building Energy and Comfort Optimization · Climate Change and Health Impacts
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Instituto Universitario de Arquitectura y Ciencias de la Construcción, Universidad de Sevilla, 41012 Seville, Spain
Escuela Técnica Superior de Arquitectura, Universidad de Sevilla, 41012 Seville, Spain
Funding
MICIU/AEI/10.13039/501100011033
References (73)
Show source-provided references
1. Analysis of Circadian Stimulus Allowed by Daylighting in Hospital Rooms10.1177/1477153515592948 ↗
2. A Systematic Literature Review: Building Window’s Influence on Indoor Circadian Health10.1016/j.rser.2023.113796 ↗
3. Sleep in the Intensive Care Unit10.1590/s1806-37562015000000056 ↗
4. Sleep in the Intensive Care Unit: A Review10.1177/0885066614538749 ↗
5. Sleep Deprivation in Critical Illness: Its Role in Physical and Psychological Recovery10.1177/0885066610394322 ↗
6. Impact of Sleep Deprivation in the Neurological Intensive Care Unit: A Narrative Review10.1007/s12028-019-00795-4 ↗
7. Short- and Long-Term Health Consequences of Sleep Disruption10.2147/NSS.S134864 ↗
8. Impact of Circadian Disruption on Cardiovascular Function and Disease10.1016/j.tem.2019.07.008 ↗
9. Cardiovascular Disease and Lifestyle Choices: Spotlight on Circadian Rhythms and Sleep10.1016/j.pcad.2023.02.004 ↗
10. Of Mice and Women: Light as a Circadian Stimulus in Breast Cancer Research10.1007/s10552-005-0574-1 ↗
11. Lighting for the Human Circadian Clock: Recent Research Indicates That Lighting Has Become a Public Health Issue10.1016/j.mehy.2004.03.020 ↗
12. Sleep during and Following Critical Illness: A Narrative Review10.5492/wjccm.v12.i3.92 ↗
13. Circadian Disruption of ICU Patients: A Review of Pathways, Expression, and Interventions10.1016/j.jcrc.2016.12.006 ↗
14. Nurses Perceptions of Sleep in the Intensive Care Unit Environment: A Literature Review10.1016/j.iccn.2013.12.005 ↗
15. Effect of Noise and Light Levels on Sleep of Intensive Care Unit Patients10.1111/nicc.12490 ↗
16. Miranda-Ackerman, R.C., Lira-Trujillo, M., Gollaz-Cervantez, A.C., Cortés-Flores, A.O., Zuloaga-Fernández del Valle, C.J., García-González, L.A., Morgan-Villela, G., Barbosa-Camacho, F.J., Pintor-Belmontes, K.J., and Guzmán-Ramírez, B.G. (2020). Associations between Stressors and Difficulty Sleeping in Critically Ill Patients Admitted to the Intensive Care Unit: A Cohort Study. BMC Health Serv. Res., 20.10.1186/s12913-020-05497-8 ↗
17. Noise in the Intensive Care Unit and Its Influence on Sleep Quality: A Multicenter Observational Study in Dutch Intensive Care Units10.1186/s13054-018-2182-y ↗
18. ‘Notes on Nursing: What It Is and What It Is Not’. (1860): By Florence Nightingale10.1016/j.nedt.2012.04.025 ↗
19. The Impact of Daytime Light Exposures on Sleep and Mood in Office Workers10.1016/j.sleh.2017.03.005 ↗
20. A Model of Phototransduction by the Human Circadian System10.1016/j.brainresrev.2005.07.002 ↗
21. Action Spectrum for Melatonin Regulation in Humans: Evidence for a Novel Circadian Photoreceptor10.1523/JNEUROSCI.21-16-06405.2001 ↗
22. An Action Spectrum for Melatonin Suppression: Evidence for a Novel Non-Rod, Non-Cone Photoreceptor System in Humans10.1111/j.1469-7793.2001.t01-1-00261.x ↗
23. Conceptual Design Metrics for Daylighting10.1177/1477153511423076 ↗
24. Ministerio de Sanidad del Gobierno de España (2022). Informe Anual Del Sistema Nacional de Salud 2020–2021. Resumen Ejecutivo, Ministerio de Sanidad del Gobierno de España.
25. Light Spectra: An Important Consideration for Circadian Alignment in the Medical ICU10.1016/j.chest.2021.07.2096 ↗
26. The Effect of Light on Sleep Quality and Physiological Parameters in Patients in the Intensive Care Unit10.1016/j.apnr.2022.151607 ↗
27. Circadian Hygiene in the ICU Environment (CHIE) Study
28. Light Patterns of the Medical ICU: Are We Disrupting Circadian Rhythms?10.1016/j.chest.2021.07.2095 ↗
29. Sound and Light in ICU during Different Environmental Conditions10.1016/j.aucc.2017.12.065 ↗
30. Lighting, Sleep and Circadian Rhythm: An Intervention Study in the Intensive Care Unit10.1016/j.iccn.2015.07.001 ↗
31. Patient Room Lighting Influences on Sleep, Appraisal and Mood in Hospitalized People10.1111/jsr.12470 ↗
32. Impact of Light Intensity on Sleep of Patients in the Intensive Care Unit: A Prospective Observational Study10.5005/jp-journals-10071-23323 ↗
33. Daylighting Design for Healthy Environments: Analysis of Educational Spaces for Optimal Circadian Stimulus10.1016/j.solener.2019.10.004 ↗
34. A Systematic Literature Review on the Rationale for and Effects of Dynamic Light Scenarios10.1016/j.buildenv.2020.107326 ↗
35. Assessment of a New Dynamic Light Regimen in a Nuclear Power Control Room without Windows on Quickly Rotating Shiftworkerseffects on Health, Wakefulness, and Circadian Alignment: A Pilot Study10.3109/07420528.2012.675850 ↗
36. Active Interventions of Dynamic Lighting on Human Circadian Rhythm and Sleep Quality in Confined Spaces10.1016/j.buildenv.2022.109766 ↗
37. Biodynamic Lighting Effects on the Sleep Pattern of People with Dementia10.1016/j.buildenv.2019.01.010 ↗
38. Bagci, S., Wieduwilt, A., Alsat, E.A., Blickwedel, J., Strizek, B., Di Battista, C., Lachner, A., Plischke, H., Melaku, T., and Müller, A. (2022). Biodynamic Lighting Conditions Preserve Nocturnal Melatonin Production in Pregnant Women during Hospitalization: A Randomized Prospective Pilot Study. Front. Endocrinol., 13.10.3389/fendo.2022.1043366 ↗
39. Shift Work and Quality of Sleep: Effect of Working in Designed Dynamic Light10.1007/s00420-015-1051-0 ↗
40. Non-Image Forming Effects of Illuminance and Correlated Color Temperature of Office Light on Alertness, Mood, and Performance across Cognitive Domains10.1016/j.buildenv.2018.12.002 ↗
41. Impact of Daylight Saving Time on Lighting Energy Consumption and on the Biological Clock for Occupants in Office Buildings10.1016/j.solener.2020.10.072 ↗
42. Dynamic Analysis of Office Lighting Smart Controls Management Based on User Requirements10.1016/j.autcon.2021.104021 ↗
43. The Potential of Simplified Concepts for Daylight Harvesting10.1191/1365782805li127oa ↗
44. Environmental Quality of University Classrooms: Subjective and Objective Evaluation of the Thermal, Acoustic, and Lighting Comfort Conditions10.1016/j.buildenv.2017.10.030 ↗
45. (1994). CIE 110-1994: Spatial Distribution of Daylight—Luminance Distributions of Various Reference Skies, Commission Internationale de l’Éclairage.
46. (2004). ISO 15469:2004. Spatial Distribution of Daylight—CIE Standard General Sky, International Standarisation Office.
47. Minimum Daylight Autonomy: A New Concept to Link Daylight Dynamic Metrics with Daylight Factors
48. Dynamic Daylight Performance Metrics for Sustainable Building Design
49. Chronobiological Aspects of Green Buildings Daylighting10.1016/j.renene.2014.06.008 ↗
50. Non-Visual Effects of Office Light Environment: Field Evaluation, Model Comparison, and Spectral Analysis10.1016/j.buildenv.2021.107859 ↗
51. Woo, M., MacNaughton, P., Lee, J., Tinianov, B., Satish, U., and Boubekri, M. (2021). Access to Daylight and Views Improves Physical and Emotional Wellbeing of Office Workers: A Crossover Study. Front. Sustain. Cities, 3.10.3389/frsc.2021.690055 ↗
52. Boubekri, M., Lee, J., MacNaughton, P., Woo, M., Schuyler, L., Tinianov, B., and Satish, U. (2020). The Impact of Optimized Daylight and Views on the Sleep Duration and Cognitive Performance of Office Workers. Int. J. Environ. Res. Public. Health, 17.10.3390/ijerph17093219 ↗
53. Ruiz, A., Campano, M.Á., Acosta, I., and Luque, Ó. (2021). Partial Daylight Autonomy (DAp): A New Lighting Dynamic Metric to Optimize the Design of Windows for Seasonal Use Spaces. Appl. Sci., 11.10.3390/app11178228 ↗
54. Ezpeleta, S., Orduna-Hospital, E., Solana, T., Aporta, J., Pinilla, I., and Sánchez-Cano, A. (2021). Analysis of Photopic and Melanopic Lighting in Teaching Environments. Buildings, 11.10.3390/buildings11100439 ↗
55. Lighting in Educational Environments: An Example of a Complete Analysis of the Effects of Daylight and Electric Light on Occupants10.1016/j.buildenv.2013.04.005 ↗
56. Acosta, I., Campano, M.Á., Bellia, L., Fragliasso, F., Diglio, F., and Bustamante, P. (2023). Impact of Daylighting on Visual Comfort and on the Biological Clock for Teleworkers in Residential Buildings. Buildings, 13.10.3390/buildings13102562 ↗
57. Nagare, R., Woo, M., MacNaughton, P., Plitnick, B., Tinianov, B., and Figueiro, M. (2021). Access to Daylight at Home Improves Circadian Alignment, Sleep, and Mental Health in Healthy Adults: A Crossover Study. Int. J. Environ. Res. Public Health, 18.10.3390/ijerph18199980 ↗
58. Abidi, S., and Rajagopalan, P. (2020). Investigating Daylight in the Apartment Buildings in Melbourne, Australia. Infrastructures, 5.10.3390/infrastructures5100081 ↗
59. Winter and Summer Analysis of Daylight Characteristics in Offices10.1016/j.buildenv.2014.06.015 ↗
60. Simulation-Based Study for Healing Environment in Intensive Care Units: Enhancing Daylight and Access to View, Optimizing an ICU Room in Temperate Climate, the Case Study of Palestine10.1016/j.asej.2022.101868 ↗
61. Insufficient Melanopic Equivalent Daylight Illuminance in Nursing Home Dementia Units across Seasons and Gaze Directions10.1177/1477153521994539 ↗
62. The Impact of Daylight and Window Views on Length of Stay among Patients with Heart Disease: A Retrospective Study in a Cardiac Intensive Care Unit10.1016/j.jointm.2022.11.002 ↗
63. (2021). Light and Lighting. Lighting of Work Places. Indoor Work Places (Standard No. EN 12464-1:2021).
64. LBNL (2012). Lawrence Berkeley National Laboratory Technical Report (2012) 1278—EnergyPlus Engineering Reference. The Reference to EnergyPlus Calculations, LBNL.
65. Comité Español de IIuminación, Instituto para la Diversificación y Ahorro de la Energía, and Ministerio de Ciencia y Tecnología, G. de España (2001). Guía Técnica de Eficiencia Energética En Iluminación. Hospitales y Centros de Atención Primaria, Instituto para la Diversificación y Ahorro de la Energía.
66. Crone, S. (1992). Radiance Users Manual Vol. 2, Lawrence Berkeley Laboratory.
67. All-Weather Model for Sky Luminance Distribution-Preliminary Configuration and Validation10.1016/0038-092X(93)90017-I ↗
68. Validation of Lighting Parametric Workflow Tools of Ladybug and Solemma Using CIE Test Cases10.1016/j.jobe.2022.105608 ↗
69. Experimental Validation of Autodesk® 3ds Max® Design 2009 and Daysim 3.0
70. Darula, S., and Kittler, R. (2002, January 11–13). CIE General Sky Standard Defining Luminance Distributions. Proceedings of the International Building Performance Simulation Association (IBPSA), Montreal, QC, Canada.
71. Mardaljevic, J. (1999). Daylight Simulation: Validation, Sky Models and Daylight Coefficients. [Ph.D. Thesis, Loughborough University].
72. Validation of a Lighting Simulation Program under Real Sky Conditions10.1177/14771535950270040701 ↗
73. Validation Study for Daylight Dynamic Metrics by Using Test Cells in Mediterranean Area10.7763/IJET.2018.V10.1107 ↗