Combating Pathogens Using Carbon-Fiber Ionizers (CFIs) for Air Purification: A Narrative Review
Source abstract
Abstract
Airborne pathogens, though a minor fraction of airborne particles, can cause infections, intoxications, or allergic reactions through respiration, dermal contact, or ingestion. The SARS-CoV-2 pandemic has underscored the significance of mitigating airborne microbial threats. Traditional air ionization methods, such as dielectric barrier discharge and metal tip corona discharge, produce ozone, a reactive and potentially harmful byproduct. However, carbon-fiber ionizers (CFIs) generate high concentrations of ions with minimal ozone production, making them a safer alternative. Operating at voltages below 5 kV, CFIs are more efficient than their metallic counterparts. This review focuses on the antimicrobial efficacy of CFIs, which produce unipolar ions that can disrupt microbial membranes, leading to cell death. Compared to ultraviolet light sterilization, CFIs are cost-effective and suitable for small spaces. The literature review highlights the need for comprehensive studies to evaluate the real-world application and effectiveness of CFIs. Many existing studies are limited by small-scale testing and insufficient data reporting, complicating comparative analyses. Our work aims to provide a detailed perspective on CFIs, examining their impact on various microorganisms, ion efficacy, ionization outcomes, and ozone generation levels. By addressing these aspects, the review seeks to offer an updated understanding of CFIs’ antimicrobial capabilities and to identify limitations in current research, paving the way for more informed and effective air purification strategies.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Chemical and Physical Studies · Biofield Effects and Biophysics · Hydrogen's biological and therapeutic effects
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Faculty of Veterinary Medicine, University of Belgrade, 11000 Belgrade, Serbia
Institute of Physics Belgrade, University of Belgrade, 11000 Belgrade, Serbia
Institute of Microbiology and Immunology, Faculty of Medicine, University of Belgrade, 11000 Belgrade, Serbia
Department of Pathological Physiology, University of Belgrade, 11000 Belgrade, Serbia
Funding
Science Fund of the Republic of Serbia
References (100+)
Show source-provided references
1. Air sampling and ATP bioluminescence for quantitative detection of airborne microbes10.1016/j.talanta.2024.126025 ↗
2. Removal of bioaerosols by the combination of a photocatalytic filter and negative air ions10.1016/j.jaerosci.2007.12.005 ↗
3. Estimating aerosol particle removal in indoor air by ion-enhanced deposition10.1016/j.jaerosci.2023.106199 ↗
4. Application of corona discharge-generated air ions for filtration of aerosolized virus and inactivation of filtered virus10.1016/j.jaerosci.2017.02.004 ↗
5. Unipolar Charging of Fine and Ultra-Fine Particles Using Carbon Fiber Ionizers10.1080/02786820802339553 ↗
6. A novel bipolar charger for submicron aerosol particles using carbon fiber ionizers10.1016/j.jaerosci.2008.11.005 ↗
7. Prediction of VOC adsorption performance for estimation of service life of activated carbon-based filter media for indoor air purification10.1016/j.buildenv.2018.12.001 ↗
8. Rashid, M.M., Tushan, S.S., Ahmed, S., and Tushar, S.I. (2019, January 5–7). Design and development of advanced Air Purifier Facial Mask. Proceedings of the International Conference on Industrial Engineering and Operations Management, Bangkok, Thailand. Available online: https://www.ieomsociety.org/ieom2019/papers/581.pdf.
9. Rafique, M.S., Tahir, M.B., Rafique, M.S., and Shakil, M. (2020). Photocatalytic Nanomaterials for Air Purification and Self-Cleaning, Elsevier Inc.10.1016/B978-0-12-821192-2.00012-7 ↗
10. Application of air ions for bacterial de-colonization in air filters contaminated by aerosolized bacteria10.1016/j.scitotenv.2010.11.012 ↗
11. Removal of submicron aerosol particles and bioaerosols using carbon fiber ionizer assisted fibrous medium filter media10.1007/s12206-009-0613-z ↗
12. Removal of PM 2.5 entering through the ventilation duct in an automobile using a carbon fiber ionizer-assisted cabin air filter10.1016/j.jaerosci.2010.07.005 ↗
13. Large-scale evaluation of microorganism inactivation by bipolar ionization and photocatalytic devices10.1016/j.buildenv.2022.109804 ↗
14. Real-time monitoring of bioaerosols via cell-lysis by air ion and ATP bioluminescence detection10.1016/j.bios.2013.09.015 ↗
15. Synergistic disinfection of aerosolized bacteria and bacteriophage by far-UVC (222-nm) and negative air ions10.1016/j.jhazmat.2022.129876 ↗
16. One-pass antibacterial efficacy of bipolar air ions against aerosolized Staphylococcus epidermidis in a duct flow10.1016/j.jaerosci.2013.12.005 ↗
17. Numerical and experimental study on airborne disinfection by negative ions in air duct flow10.1016/j.buildenv.2017.11.006 ↗
18. Park, J.S., Sung, B.J., Yoon, K.S., and Jeong, C.S. (2016). The bactericidal effect of an ionizer under low concentration of ozone. BMC Microbiol., 16.10.1186/s12866-016-0785-5 ↗
19. Enhanced Antimicrobial Activity on Non-Conducting and Conducting Air Filters by Using Air Ions and Grapefruit Seed Extract10.4209/aaqr.2016.10.0466 ↗
20. Positive and Negative Ions Potently Inhibit the Viability of Airborne Gram-Positive and Gram-Negative Bacteria10.1128/Spectrum.00651-21 ↗
21. Use of Negative and Positive Ions for Reducing Bacterial Pathogens to Control Infections10.31080/ASMI.2019.02.0395 ↗
22. Effetti della ionizzazione dell’aria su alcuni ceppi batterici (Effects of ionization of the air on some bacterial strains)
23. Evaluation of a bipolar ionization device in inactivation of antimicrobial-resistant bacteria, yeast, Aspergillus spp. and human coronavirus10.1016/j.jhin.2022.04.004 ↗
24. Electrostatic precipitation (ESP) index driven bio-aerosol collection for a high biological viability sampling10.1016/j.jclepro.2023.138790 ↗
25. Design and Evaluation of the Field-Deployable Electrostatic Precipitator with Superhydrophobic Surface (FDEPSS) with High Concentration Rate10.4209/aaqr.2015.04.0206 ↗
26. Collection of airborne microorganisms by electrostatic precipitation10.1016/S0021-8502(02)00091-5 ↗
27. Antimicrobial action of essential oil vapours and negative air ions against Pseudomonas fluorescens10.1016/j.ijfoodmicro.2010.08.023 ↗
28. Interaction of ozone and negative air ions to control micro-organisms10.1046/j.1365-2672.2002.01683.x ↗
29. Ion-Based Metal/Graphene Antibacterial Agents Comprising Mono-Ionic and Bi-Ionic Silver and Copper Species10.1021/acs.langmuir.8b01880 ↗
30. Indoor airborne disinfection with electrostatic disinfector (ESD): Numerical simulations of ESD performance and reduction of computing time10.1016/j.buildenv.2021.107956 ↗
31. Inactivation of airborne bacteria by cold plasma in air duct flow10.1016/j.buildenv.2016.06.026 ↗
32. Application of cold plasma and ozone technology for decontamination of Escherichia coli in foods—A review10.1016/j.foodcont.2021.108338 ↗
33. Effect of air ions on bacterial aerosols10.1007/BF02186925 ↗
34. Bactericidal Effects of Negative and Positive Ions Generated in Nitrogen on Starved Pseudomonas Veronii10.1016/S0304-3886(02)00110-9 ↗
35. The application of ionizers in domestic refrigerators for reduction in airborne and surface bacteria10.1111/j.1365-2672.2009.04359.x ↗
36. Use of Negative Air Ionization for Reducing Bacterial Pathogens and Spores on Stainless Steel Surfaces10.1093/japr/13.2.200 ↗
37. Fletcher, L.A., Gaunt, L.F., Beggs, C.B., Shepherd, S.J., Sleigh, P.A., Noakes, C.J., and Kerr, K.G. (2007). Bactericidal action of positive and negative ions in air. BMC Microbiol., 7.10.1186/1471-2180-7-32 ↗
38. Escombe, A.R., Moore, D.A., Gilman, R.H., Navincopa, M., Ticona, E., Mitchell, B., Noakes, C., Martínez, C., Sheen, P., and Ramirez, R. (2009). Upper-room ultraviolet light and negative air ionization to prevent tuberculosis transmission. PLoS Med., 6.10.1371/journal.pmed.1000043 ↗
39. Ahmed, W., Al-Marzouqi, A.H., Nazir, M.H., Rizvi, T.A., Zaneldin, E., and Khan, M. (2022). Comparative Experimental Investigation of Biodegradable Antimicrobial Polymer-Based Composite Produced by 3D Printing Technology Enriched with Metallic Particles. Int. J. Mol. Sci., 23.10.3390/ijms231911235 ↗
40. Controlling Legionella in hospital drinking water: An evidence-based review of disinfection methods10.1086/657934 ↗
41. Experiences of the first 16 hospitals using copper-silver ionization for Legionella control: Implications for the evaluation of other disinfection modalities10.1086/502251 ↗
42. Controlling Legionella in hospital water systems: Experience with the superheat-and-flush method and copper-silver ionization10.1086/647762 ↗
43. Application of negative air ionization for reducing experimental airborne transmission of Salmonella enteritidis to chicks10.1093/ps/78.1.57 ↗
44. Use of Negative Air Ionization for Reducing Airborne Levels of Salmonella enterica serovar enteritidis in a Room Containing Infected Caged Layers10.1093/japr/8.4.440 ↗
45. Bactericidal effects of negative air ions on airborne and surface Salmonella enteritidis from an artificially generated aerosol10.4315/0362-028X-64.1.113 ↗
46. Superoxide involvement in the bactericidal effects of negative air ions on Staphylococcus albus10.1038/281400a0 ↗
47. Unipolar ion emission enhances respiratory protection against fine and ultrafine particles10.1016/j.jaerosci.2004.05.006 ↗
48. Aplin, K.L., and Harrison, R.G. (2015). Electricity in the Atmosphere; Ions in the Atmosphere. Encyclopedia of Atmospheric Sciences, Academic Press. [2nd ed.].10.1016/B978-0-12-382225-3.00145-6 ↗
49. Some effects of ionized air on Penicillium notatum10.1002/jps.3030491004 ↗
50. Sensitivity of Candida albicans to negative air ion streams10.1046/j.1365-2672.1999.00944.x ↗
51. Electronics, Sanyo Home Appliances Research Program (2005). Sharp’s plasmacluster ions effectively deactivate H5N1 avian influenza virus. Asia Pac. Biotech. News., 6.
52. Methods for air cleaning and protection of building occupants from airborne pathogens10.1016/j.buildenv.2008.09.001 ↗
53. Inactivation of RNA and DNA viruses in water by copper and silver ions and their synergistic effect10.1016/j.wroa.2020.100077 ↗
54. The Efficacy of Plant-Based Ionizers in Removing Aerosol for COVID-19 Mitigation10.34133/2021/2173642 ↗
55. Van Egeren, D., Stoddard, M., Malakar, A., Ghosh, D., Acharya, A., Mainuddin, S., Majumdar, B., Luo, D., Nolan, R.P., and Joseph-McCarthy, D. (2022). No magic bullet: Limiting in-school transmission in the face of variable SARS-CoV-2 viral loads. Front. Public Health, 10.10.3389/fpubh.2022.941773 ↗
56. Removal of SARS-CoV-2 using UV+Filter in built environment10.1016/j.scs.2021.103226 ↗
57. Zhang, C., Cui, H., Zhang, C., Chen, Z., Jiang, X., Liu, J., Wan, Z., Li, J., Liu, J., and Gao, Y. (2022). Aerosol Transmission of the Pandemic SARS-CoV-2 and Influenza A Virus Was Blocked by Negative Ions. Front. Cell. Infect. Microbiol., 12.10.3389/fcimb.2022.897416 ↗
58. Effect of Negative Air Ionization on Airborne Transmission of Newcastle Disease Virus10.2307/1592107 ↗
59. The effect of air ionization on the air-borne transmission of experimental Newcastle disease virus infections in chickens10.1017/S0022172400025821 ↗
60. Park, D.H., An, S.H., Lee, Y., Kim, Y.J., Han, B., and Kim, H.J. (2022). Development of On-Demand Antiviral Electrostatic Precipitators with Electrothermal-Based Antiviral Surfaces against Airborne Virus Particles. Toxics, 10.10.3390/toxics10100601 ↗
61. Heo, J., Lee, J., and Park, D. (2022). Effects of Brush-Type Ionizer Materials on Virus Inactivation. Toxics, 10.10.3390/toxics10100611 ↗
62. Performance evaluation of an electrostatic precipitator with a copper plate using an aerosolized SARS-CoV-2 surrogate (bacteriophage phi 6)10.1016/j.eti.2023.103124 ↗
63. Hagbom, M., Nordgren, J., Nybom, R., Hedlund, K.O., Wigzell, H., and Svensson, L. (2015). Ionizing air affects influenza virus infectivity and prevents airborne-transmission. Sci. Rep., 5.10.1038/srep11431 ↗
64. (2003). Cleanrooms and Associated Controlled Environments-Biocontamination Control: Part 1: General Principles and Methods (Standard No. ISO 14698-1:2003).
65. Ouyang, H., Wang, L., Sapkota, D., Yang, M., Morán, J., Li, L., Olson, B.A., Schwartz, M., Hogan, C.J., and Torremorell, M. (2023). Control technologies to prevent aerosol-based disease transmission in animal agriculture production settings: A review of established and emerging approaches. Front. Vet. Sci., 10.10.3389/fvets.2023.1291312 ↗
66. How does decarbonization of the central heating industry affect employment? A spatiotemporal analysis from the perspective of urbanization10.1016/j.enbuild.2024.113912 ↗
67. Conceptual model of comprehensive research metrics for improved human health and environment10.1289/ehp.10925 ↗
68. The National Human Activity Pattern Survey (NHAPS): A resource for assessing exposure to environmental pollutants10.1038/sj.jea.7500165 ↗
69. Viral infections acquired indoors through airborne, droplet or contact transmission
70. Air purifiers: A supplementary measure to remove airborne SARS-CoV-210.1016/j.buildenv.2020.106918 ↗
71. A review of methods to reduce the probability of the airborne spread of COVID-19 in ventilation systems and enclosed spaces10.1016/j.envres.2021.111765 ↗
72. Block, S.S. (2001). Disinfection, Sterilization, and Preservation, Lippincott Williams & Wilkins.
73. Control technology of pathogenic biological aerosol: Review and prospect10.1016/j.buildenv.2023.110679 ↗
74. Developing an Optimal Antiviral Method for the Air-filtration System of Subway Stations10.4209/aaqr.230088 ↗
75. Control of aerosol contaminants in indoor air: Combining the particle concentration reduction with microbial inactivation10.1021/es061373o ↗
76. Jiang, S.-Y., Ma, A., and Ramachandran, S. (2018). Negative Air Ions and Their Effects on Human Health and Air Quality Improvement. Int. J. Mol. Sci., 19.10.3390/ijms19102966 ↗
77. Cappa, C. (2024, July 09). Air Pollutant Emissions and Possible Health Effects Associated with Electronic Air Cleaners, Available online: https://ww2.arb.ca.gov/sites/default/files/2023-09/CARB%2022RD003%20White%20Paper%20Sept%2020%202023.pdf.
78. Evaluation of Negative Air Ions in Bioaerosol Removal: Indoor Concentration of Airborne Bacterial and Fungal in Residential Building in Qom City, Iran
79. Evaluation of ionic air purifiers for reducing aerosol exposure in confined indoor spaces10.1111/j.1600-0668.2005.00364.x ↗
80. Submicrometer particle removal indoors by a novel electrostatic precipitator with high clean air delivery rate, low ozone emissions, and carbon fiber ionizer10.1111/ina.12037 ↗
81. Inactivation of airborne bacteria using different UV sources: Performance modeling, energy utilization, and endotoxin degradation10.1016/j.scitotenv.2018.11.266 ↗
82. The effect of negative air ion exposure on Escherichia coli and Pseudomonas fluorescens10.1080/10934520801959831 ↗
83. Mata, T.M., Martins, A.A., Calheiros, C.S.C., Villanueva, F., Alonso-Cuevilla, N.P., Gabriel, M.F., and Silva, G.V. (2022). Indoor Air Quality: A Review of Cleaning Technologies. Environments, 9.10.3390/environments9090118 ↗
84. Emission rates of indoor ozone emission devices: A literature review10.1016/j.buildenv.2019.05.024 ↗
85. Performance of wearable ionization air cleaners: Ozone emission and particle removal10.1080/02786826.2016.1139045 ↗
86. (2021). WHO Global Air Quality Guidelines. Particulate Matter (PM2.5 And Pmio), Ozone, Nitrogen Dioxide, Sulfur Dioxide and Carbon Monoxide, World Health Organization.
87. WHO Regional Office for Europe (2024, June 19). Review of Evidence on Health Aspects of Air Pollution—REVIHAAP Project, Available online: https://www.ncbi.nlm.nih.gov/books/NBK361805/.
88. (2024, July 03). United States Environmental Protection Agency, Available online: https://www.epa.gov/ozone-pollution-and-your-patients-health/course-outline-and-key-points-ozone.
89. On assessment of ozone generation in dc coronas10.1088/0022-3727/33/7/312 ↗
90. Ultrafine particle cleaning performance of an ion spray electrostatic air cleaner emitting zero ozone with diffusion charging by carbon fiber10.1016/j.buildenv.2019.106422 ↗
91. Using an insulating fiber as the sampling probe and ionization substrate for ambient ionization–mass spectrometric analysis of volatile, semi-volatile, and polar analytes10.1007/s00216-022-04080-w ↗
92. Inactivation of Norovirus by ozone gas in conditions relevant to healthcare10.1016/j.jhin.2006.12.021 ↗
93. Vertically oriented graphene sheets grown on metallic wires for greener corona discharges: Lower power consumption and minimized ozone emission10.1039/c1ee01140e ↗
94. Suppression of particle generation in a modified clean room corona air ionizer10.1016/0021-8502(90)90074-8 ↗
95. Recent advances in materials science: A reinforced approach toward challenges against COVID-1910.1007/s42247-021-00179-5 ↗
96. A novel electrostatic precipitator-type small air purifier with a carbon fiber ionizer and an activated carbon fiber filter10.1016/j.jaerosci.2017.12.014 ↗
97. World Health Organization (2006). Air Quality Guidelines for Particulate Matter, Ozone, Nitrogen Dioxide and Sulfur Dioxide: Global Update, WHO Regional Office for Europe.
98. (2024, June 22). National Ambient Air Quality Standards for Ozone, EPA-HQ-OAR, Available online: https://www.govinfo.gov/content/pkg/FR-2018-12-06/pdf/2018-25424.pdf.
99. Young, T.M., Sobek, E., and Farahi, F. (2022). Quantifying the Natural Variation of ‘Data Signatures’ from Aerosols Using Statistical Control Bands. Mathematics, 10.10.3390/math10122103 ↗
100. HEPA Filters