Research on a Neutron Detector with a Boron-Lined Multilayer Converter
Source abstract
Abstract
3He is a splendid neutron detection material due to its high neutron reaction cross section, gaseous state, and nonelectronegative and nonpoisonous nature. With the worldwide problem of the “3He supply crisis” arising, boron-lined gaseous neutron detectors are being widely used in neutron detection to replace 3He neutron detectors. In this work, to reduce the scattering neutron background coming from the substrate of a boron-lined neutron detector in the application of neutron scattering, a new design of the boron-lined gaseous neutron detector composed of a boron-lined multichip converter and a multiwire proportional chamber was proposed. The electron drift efficiency matrix simulated by Garfield++ (Version 2023.4) and the values and positions of electron energy deposition simulated by Geant4 were obtained. The α, 7Li, and total charged particle energy deposition spectra were acquired via coupling calculations of the electron drift efficiency matrix and the values and positions of electron energy deposition, and the width of the slit was selected as 3 mm. The boron-lined multilayer converter neutron detector (BMCND) was tested using a 241Am–239Pu mixture α source, and the total count rate of α charged particles was measured as 599.5 s−1, which is 89% of the theoretical α particle emission rate of 672.9 s−1. The drift voltage experiments showed that 1200 V is enough to acquire a relatively ideal count, and a 2500 V drift voltage was confirmed, considering the higher count and instrument safety. We also performed the neutron detection experiments using a photo-neutron source, and a characteristic spectrum shape of “two stairs” was measured. When borated polyethylene was used to shield the BMCND, the detected total count decreased while keeping the characteristic spectrum shape, demonstrating that the BMCND was equipped with the ability to detect neurons, indicating that BMCNDs have the potential to be an outstanding 3He alternative neutron detector.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Radiation Detection and Scintillator Technologies · Nuclear Physics and Applications · Radiation Therapy and Dosimetry
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Physics and Electronic Engineering, Sichan University of Science and Engineering, Zigong 643000, China
Funding
National Natural Science Foundation of China · National Defense Technology Foundation Program of China · Sichuan Science and Technology Program · Talent Project of Sichuan University of Science and Engineering · the Scientific Research and Innovation Team Program of Sichuan University of Science and Engineering
References (40)
Show source-provided references
1. Why new neutron detector materials must replace helium-310.1140/epjp/i2014-14236-6 ↗
2. Progress in alternative neutron detection to address the helium-3 shortage10.1016/j.nima.2014.10.046 ↗
3. Kouzes, R.T. (2009). The 3He Supply Problem.10.2172/956899 ↗
4. Shea, D.A., and Morgan, D.L. (2010). The Helium-3 Shortage: Supply, Demand, and Options for Congress.
5. 3He supply crisis: Reasons and challenges10.1007/s10556-013-9701-0 ↗
6. Lacy, J.L., Athanasiades, A., Martin, C.S., Sun, L., Vazquez-Flores, G.J., and Lyons, T.D. (November, January 30). Boron-coated straw detectors: A novel approach for helium-3 neutron detector replacement. Proceedings of the IEEE Nuclear Science Symposuim & Medical Imaging Conference, Knoxville, TN, USA.
7. Boron-coated straw detectors for backpack monitors10.1109/TNS.2013.2245915 ↗
8. Large-scale boron-lined neutron detectors for Cosmic-Ray Neutron Sensing
9. Large-scale boron-lined neutron detection systems as a 3He alternative for cosmic ray neutron sensing10.3389/frwa.2020.00016 ↗
10. Deng, C., Tuo, X., Peng, S., Yu, Y., Fang, Z., Wang, Q., Liu, L., and Yang, Y. (November, January 26). An angular sensitivity study of the boron-lined honeycomb convertor neutron detector used for the small angle neutron scattering. Proceedings of the 2019 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Manchester, UK.10.1109/NSS/MIC42101.2019.9059999 ↗
11. Characterization of the Multi-Blade 10B-based detector at the CRISP reflectometer at ISIS for neutron reflectometry at ESS10.1088/1748-0221/13/05/P05009 ↗
12. Multi-Grid detector for neutron spectroscopy: Results obtained on time-of-flight spectrometer CNCS10.1088/1748-0221/12/04/P04030 ↗
13. Novel boron-10-based detectors for neutron scattering science: Helium-3-free detectors for large-and small-area applications: The Multi-Grid and the Multi-Blade prototypes10.1140/epjp/i2015-15027-3 ↗
14. Evolution in boron-based GEM detectors for diffraction measurements: From planar to 3D converters10.1088/0957-0233/27/11/115902 ↗
15. Boron-coated straws as a replacement for 3He-based neutron detectors10.1016/j.nima.2010.09.011 ↗
16. Chen, C., Gong, H., Yang, Y., Zhu, S., Huang, T., Wang, Y., Wang, X., and Li, Y. (November, January 27). Realization and test of position sensitive boron coated straw-tube. Proceedings of the 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC), Seoul, Republic of Korea.
17. 10B4C Multi-Grid as an Alternative to 3He for Large Area Neutron Detectors10.1109/TNS.2012.2227798 ↗
18. Khaplanov, A. (2012). Multi-Grid Boron-10 detector for large area applications in neutron scattering science. arXiv.
19. Yang, Y., Li, C., Chen, C., Wang, X., and Li, Y. (November, January 26). Research of boron lined honey-neutron detector realized with atomic layer deposition. Proceedings of the 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC), Seoul, Republic of Korea.
20. Fang, Z., Yang, Y., and Li, Y. (November, January 31). The research of high detection efficiency boron lined detector with a honeycomb neutron converter. Proceedings of the 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), San Diego, CA, USA.10.1109/NSSMIC.2015.7582005 ↗
21. Research on a neutron detector with a boron-lined honeycomb neutron converter10.1109/TNS.2017.2670639 ↗
22. The Multi-Blade Boron-10-based neutron detector performance using a focusing reflectometer10.1088/1748-0221/15/03/P03010 ↗
23. The Multi-Blade Boron-10-based neutron detector for high intensity neutron reflectometry at ESS10.1088/1748-0221/12/03/P03013 ↗
24. Experimental research on a THGEM-based thermal neutron detector10.1088/1674-1137/39/5/056002 ↗
25. GEM-based detectors for thermal and fast neutrons10.1140/epjp/i2015-15118-1 ↗
26. Study of a nTHGEM-based thermal neutron detector10.1088/1674-1137/40/7/076002 ↗
27. A new neutron detector based on ceramic THGEM and boron-coated meshes10.1007/s41605-018-0055-1 ↗
28. Fang, Z., Yang, Y., Li, Y., and Wang, X. (2017, January 21–28). The research on the suppression of spurious neutrons for a neutron detector array that may be used in the neutron scattering. Proceedings of the 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Atlanta, GA, USA.10.1109/NSSMIC.2017.8532603 ↗
29. GEANT4-a simulation toolkit10.1016/S0168-9002(03)01368-8 ↗
30. Geant4 developments and applications10.1109/TNS.2006.869826 ↗
31. Recent developments in Geant410.1016/j.nima.2016.06.125 ↗
32. THGEM gain calculations using Garfield++: Solving discrepancies between simulation and experimental data10.1088/1748-0221/11/08/P08018 ↗
33. Interfacing Geant4, Garfield++ and Degrad for the simulation of gaseous detectors10.1016/j.nima.2019.04.110 ↗
34. Preparation and characterization of boron films used for boron-lined gaseous neutron detectors10.1007/s40042-021-00256-2 ↗
35. Realization and evaluation of the Boron Nano Particle-based drip-coating method for boron-lined gaseous neutron detectors10.1088/1748-0221/14/12/P12003 ↗
36. Multiwire Chambers, Drift Chambers and Some of their Applications10.1051/epn/19791007007 ↗
37. Multiwire proportional chambers and drift chambers10.1016/0029-554X(79)90726-2 ↗
38. Research on angle sensitivity of the boron-lined multilayer converter neutron detector10.1088/1361-6501/ac51ee ↗
39. Zhao, Y., Cui, T., and Yang, Y. (2017, January 21–28). The design of a photoneutron source for the narcotic drugs detection in a large-truck. Proceedings of the 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Atlanta, GA, USA.10.1109/NSSMIC.2017.8532992 ↗
40. Cui, T., Yang, Y., Zhang, Z., Zong, C., Ming, S., and Wang, D. (November, January 31). An e-LINAC driven PGNAA system for concealed drug inspection. Proceedings of the 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Boston, MA, USA.10.1109/NSS/MIC42677.2020.9508075 ↗