Integrating Finite Element Data with Neural Networks for Fatigue Prediction in Titanium Dental Implants: A Proof-of-Concept Study
Source abstract
Abstract
Background: Titanium dental implants are widely used, but their long-term mechanical reliability under fatigue loading remains a key concern. Traditional finite element analysis is accurate but computationally intensive. This study explores the integration of finite element analysis data with neural networks to predict fatigue-related responses efficiently. Methods: A dataset of 200 finite element analysis simulations was generated, varying load intensity, load angle, and implant size. Each simulation provided three outputs: maximum von Mises stress, maximum displacement, and fatigue safety factor. A feedforward neural network with two hidden layers (64 neurons each, ReLU activation) was trained using 160 simulations, with 40 reserved for testing. Results: The neural network achieved high accuracy across all outputs, with R2 values of 0.97 for stress, 0.95 for deformation, and 0.92 for the fatigue safety factor. Mean errors across the test set were below 5%, indicating strong predictive performance under diverse conditions. Conclusions: The findings demonstrate that neural networks can reliably replicate finite element analysis outcomes with significantly reduced computational time. This approach offers a promising tool for accelerating implant assessment and supports the growing role of AI in biomechanical design and analysis.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Modelling, Simulation and Data Analysis Group for Engineering Industrial, UNIE Universidad, Calle Arapiles 14, 28015 Madrid, Spain
Escuela Superior de Ingeniería y Tecnología, Universidad Internacional de La Rioja (UNIR), Avenida de la Paz, 137, 26006 Logroño, Spain
Faculty of Digital Business, Technology and Law, UTAMED (Universidad Tecnológica Atlántico Mediterráneo), C. de Marie Curie, 1, Campanillas, 29590 Málaga, Spain
References (29)
Show source-provided references
1. A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDPs) after a mean observation period of at least 5 years10.1111/j.1600-0501.2012.02546.x ↗
2. The long-term efficacy of currently used dental implants: A review and proposed criteria of success
3. Biomedical Applications of Titanium and its Alloys10.1007/s11837-008-0031-1 ↗
4. Gasik, M., Lambert, F., and Bacevic, M. (2021). Biomechanical Properties of Bone and Mucosa for Design and Application of Dental Implants. Materials, 14.10.3390/ma14112845 ↗
5. Application of finite element analysis in implant dentistry: A review of the literature10.1067/mpr.2001.115251 ↗
6. Application of the finite element method in dental implant research10.1080/10255840600837074 ↗
7. Evaluation of Fatigue Life for Dental Implants Using FEM Analysis10.3390/prosthesis3040028 ↗
8. Zieliński, R., Lipa, S., Piechaczek, M., Sowiński, J., Kołkowska, A., and Simka, W. (2024). Finite Element Analysis and Fatigue Test of INTEGRA Dental Implant System. Materials, 17.10.3390/ma17051213 ↗
9. A deep learning approach to estimate stress distribution: A fast and accurate surrogate of finite-element analysis10.1098/rsif.2017.0844 ↗
10. Application of neural networks for the prediction of cartilage stress in a musculoskeletal system10.1016/j.bspc.2013.04.004 ↗
11. Griggs, J.A. (2023). Artificial Neural Networks for the Design Optimization of Implants. Artificial Intelligence in Dentistry, Springer International Publishing.10.1007/978-3-031-43827-1_6 ↗
12. Combined effects of implant insertion depth and alveolar bone quality on periimplant bone strain induced by a wide-diameter, short implant and a narrow-diameter, long implant10.1016/S0022-3913(10)60142-4 ↗
13. Boyer, H.E. (2006). Atlas of Fatigue Curves, ASM International.
14. Design of patient specific basal dental implant using Finite Element method and Artificial Neural Network technique10.1177/09544119221114729 ↗
15. Design of patient specific dental implant using FE analysis and computational intelligence techniques10.1016/j.asoc.2018.01.025 ↗
16. Finite element analysis of the influence of implant inclination, loading position, and load direction on stress distribution10.1007/s10266-003-0029-7 ↗
17. Neural network integrated with symbolic regression for multiaxial fatigue life prediction10.1016/j.ijfatigue.2024.108535 ↗
18. Marković, E., Marohnić, T., and Basan, R. (2025). A Surrogate Artificial Neural Network Model for Estimating the Fatigue Life of Steel Components Based on Finite Element Simulations. Materials, 18.10.3390/ma18122756 ↗
19. Numerical study of steel–concrete composite beam with composite dowels connectors10.1016/j.compstruc.2021.106618 ↗
20. The Transition from Rebound to Bonding in High-Velocity Metallic Microparticle Impacts: Jetting-Associated Power-Law Divergence10.1115/1.4047206 ↗
21. Three-dimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support, prosthesis type, and loading during function10.1016/S0022-3913(96)90442-4 ↗
22. Martinez-Mondragon, M., Urriolagoitia-Sosa, G., Romero-Ángeles, B., García-Laguna, M.A., Laguna-Canales, A.S., Pérez-Partida, J.C., Mireles-Hernández, J., Carrasco-Hernández, F., and Urriolagoitia-Calderón, G.M. (2024). Biomechanical Fatigue Behavior of a Dental Implant Due to Chewing Forces: A Finite Element Analysis. Materials, 17.10.3390/ma17071669 ↗
23. Physics-informed neural networks: A deep learning framework for solving forward and inverse problems involving nonlinear partial differential equations10.1016/j.jcp.2018.10.045 ↗
24. A physics-informed neural network for creep-fatigue life prediction of components at elevated temperatures10.1016/j.engfracmech.2021.108130 ↗
25. (2016). Medical Device Software—Software life-Cycle Processes (Standard No. UNE-EN 62304:2007/A1:2016).
26. (2020). Medical Devices—Application of Risk Management to Medical Devices (Standard No. UNE-EN ISO 14971:2020).
27. (2015). Medical Devices—Part 1: Application of Usability Engineering to Medical Devices (Endorsed by AENOR in June of 2015) (Standard No. UNE-EN 62366-1:2015).
28. (2016). Reglamento General de Protección de Datos (RGPD) o Reglamento
29. (UE) (Standard No. GDPR 2016/679).