Abstract

This study presents an air quality monitoring system that employs the Arduino Uno microcontroller. The system is augmented with a moving average filter and data fusion techniques from BME680 and CCS811 sensors, which are designed to process and combine data from these sensors. The system was tested and analyzed empirically across a range of residential environments in order to validate its efficacy. The findings indicated that the typical IAQ level in a bedroom was approximately 20 units. However, this level increased significantly, reaching 140 units, within minutes after the introduction of a 17% perfume spray. In contrast, the use of an aromatic diffuser resulted in a smaller increase in IAQ to 40 units, which returned to normal levels after ventilation. Moreover, the analysis demonstrated that the kitchen and bathroom exhibited inferior air quality in comparison to the bedroom. This was evidenced by elevated VOC and humidity levels, which were observed to be 10–20% higher due to the combined effects of household activities and inadequate ventilation. This study makes a significant contribution to the field of air quality monitoring by proposing a solution that employs sensor technology and data processing methods to enhance the quality of life within residential spaces.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Air Quality Monitoring and Forecasting · Building Energy and Comfort Optimization · Fire Detection and Safety Systems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Specialized Computer Systems Department, Lviv Polytechnic National University, 12 Bandera Str., 79013 Lviv, Ukraine

Department of Electronics and Computer Technologies, Ivan Franko National University of Lviv, 50 Dragomanov Str., 79005 Lviv, Ukraine

Department of Fire Tactics and Emergency Rescue Work, Lviv State University of Life Safety, 35 Kleparivska Str., 79007 Lviv, Ukraine

Institute of Solid State Physics, University of Latvia, 8 Kengaraga, LV-1063 Riga, Latvia

Funding

Ministry of Education and Science of Ukraine · Institute of Solid State Physics, University of Latvia

References (56)

Show source-provided references
1. Multi-points indoor air quality monitoring based on internet of things10.1109/ACCESS.2021.3073681 ↗
2. De Capua, C., Fulco, G., Lugarà, M., and Ruffa, F. (2023). An improvement strategy for indoor air quality monitoring systems. Sensors, 23.10.3390/s23083999 ↗
3. Monitoring and apportioning sources of indoor air quality using low-cost particulate matter sensors10.1016/j.envint.2023.107907 ↗
4. An agent based traffic regulation system for the roadside air quality control10.1109/ACCESS.2017.2725984 ↗
5. Streamlining IAQ guidelines and investigating the effect of door opening/closing on concentrations of VOCs, formaldehyde, and NO2 in office buildings10.1016/j.buildenv.2018.03.029 ↗
6. Volatile organic compound optical fiber sensors: A review10.3390/s6111440 ↗
7. Spinelle, L., Gerboles, M., Kok, G., Persijn, S., and Sauerwald, T. (2017). Review of portable and low-cost sensors for the ambient air monitoring of benzene and other volatile organic compounds. Sensors, 17.10.3390/s17071520 ↗
8. Development of an IoT-based indoor air quality monitoring platform
9. Sensors for volatile organic compounds10.1021/acsnano.1c10827 ↗
10. Risk assessment of exposure to volatile organic compounds in different indoor environments10.1016/S0013-9351(03)00035-5 ↗
11. Yan, Y., Li, Y., Sun, M., and Wu, Z. (2019). Primary pollutants and air quality analysis for urban air in China: Evidence from Shanghai. Sustainability, 11.10.3390/su11082319 ↗
12. Nguyen, T., Qin, X., Dinh, A., and Bui, F. (2019). Low resource complexity R-peak detection based on triangle template matching and moving average filter. Sensors, 19.10.3390/s19183997 ↗
13. Armand, T.P.T., Mozumder, M.A.I., Ali, S., Amaechi, A.O., and Kim, H.C. (2023). Developing a low-cost IoT-based remote cardiovascular patient monitoring system in Cameroon. Healthcare, 11.10.3390/healthcare11020199 ↗
14. Carnevale, C., Angelis, E.D., Finzi, G., Turrini, E., and Volta, M. (2020). Application of data fusion techniques to improve air quality forecast: A case study in the northern Italy. Atmosphere, 11.10.3390/atmos11030244 ↗
15. Sánchez-Barajas, M.A., Cuevas-González, D., Reyna, M.A., Delgado-Torres, J.C., Altamira-Colado, E., and López-Avitia, R. (2023). Development of a low-cost particulate matter optical sensor for real-time monitoring. Eng. Proc., 58.10.3390/ecsa-10-16025 ↗
16. An adaptive indoor air quality control scheme for minimizing volatile organic compounds density10.1109/ACCESS.2020.2969212 ↗
17. Mannan, M., and Al-Ghamdi, S.G. (2021). Indoor air quality in buildings: A comprehensive review on the factors influencing air pollution in residential and commercial structure. Int. J. Environ. Res. Public Health, 18.10.3390/ijerph18063276 ↗
18. Modeling and control of hybrid ventilation in a building with double skin façade10.1109/ACCESS.2020.3024260 ↗
19. Tanji, A.K., de Brito, M.A., Alves, M.G., Garcia, R.C., Chen, G.L., and Ama, N.R. (2021). Improved noise cancelling algorithm for electrocardiogram based on moving average adaptive filter. Electronics, 10.10.3390/electronics10192366 ↗
20. Venkatraman Jagatha, J., Klausnitzer, A., Chacón-Mateos, M., Laquai, B., Nieuwkoop, E., van der Mark, P., Vogt, U., and Schneider, C. (2021). Calibration method for particulate matter low-cost sensors used in ambient air quality monitoring and research. Sensors, 21.10.3390/s21123960 ↗
21. Kang, J., and Hwang, K.I. (2016). A comprehensive real-time indoor air-quality level indicator. Sustainability, 8.10.3390/su8090881 ↗
22. Taştan, M., and Gökozan, H. (2019). Real-time monitoring of indoor air quality with internet of things-based E-nose. Appl. Sci., 9.10.3390/app9163435 ↗
23. Sun, S., Zheng, X., Villalba-Díez, J., and Ordieres-Meré, J. (2019). Indoor air-quality data-monitoring system: Long-term monitoring benefits. Sensors, 19.10.3390/s19194157 ↗
24. Zhang, H., and Srinivasan, R. (2020). A systematic review of air quality sensors, guidelines, and measurement studies for indoor air quality management. Sustainability, 12.10.3390/su12219045 ↗
25. Indoor environments and health: Moving into the 21st century10.2105/AJPH.93.9.1489 ↗
26. Salamone, F., Belussi, L., Danza, L., Galanos, T., Ghellere, M., and Meroni, I. (2017). Design and development of a nearable wireless system to control indoor air quality and indoor lighting quality. Sensors, 17.10.3390/s17051021 ↗
27. Choi, Y., Lim, Y., Kim, J., and Song, D. (2020). Why does a high humidity level form in low-income households despite low water vapor generation?. Sustainability, 12.10.3390/su12187563 ↗
28. From COVID-19 to future electrification: Assessing traffic impacts on air quality by a machine-learning model10.1073/pnas.2102705118 ↗
29. da Silva Sousa, D., Leal, V.G., dos Reis, G.T., da Silva, S.G., Cardoso, A.A., and da Silveira Petruci, J.F. (2022). An automated, self-powered, and integrated analytical platform for on-line and in situ air quality monitoring. Chemosensors, 10.10.3390/chemosensors10110454 ↗
30. Khan, A.U., Khan, M.E., Hasan, M., Zakri, W., Alhazmi, W., and Islam, T. (2022). An Efficient wireless sensor network based on the ESP-MESH protocol for indoor and outdoor air quality monitoring. Sustainability, 14.10.3390/su142416630 ↗
31. (2024, July 30). DIY Air Quality Monitor—PM2.5, CO2, VOC, Ozone, Temp & Hum Arduino Meter. How To Mechatronics. Available online: https://howtomechatronics.com/projects/diy-air-quality-monitor-pm2-5-co2-voc-ozone-temp-hum-arduino-meter/.
32. Venturini, A., Pancake, M., VanCleave, W., Wan, Y., and Cornish, K. (2022). Invention of a medical glove durability assessment device. Inventions, 7.10.3390/inventions7030062 ↗
33. Pazzi, B.M., Pistoia, D., and Alberti, G. (2022). RGB-Detector: A smart, low-cost device for reading RGB indexes of microfluidic paper-based analytical devices. Micromachines, 13.10.3390/mi13101585 ↗
34. Domínguez-Amarillo, S., Fernández-Agüera, J., Cesteros-García, S., and González-Lezcano, R.A. (2020). Bad air can also kill: Residential indoor air quality and pollutant exposure risk during the COVID-19 crisis. Int. J. Environ. Res. Public Health, 17.10.3390/ijerph17197183 ↗
35. Development of an Internet of Things solution to monitor and analyse indoor air quality10.1016/j.iot.2021.100392 ↗
36. Data fusion for air quality mapping using low-cost sensor observations: Feasibility and added-value10.1016/j.envint.2020.105965 ↗
37. Advances in multi-sensor data fusion: Algorithms and applications10.3390/s91007771 ↗
38. Seasonal variation of air quality in hospitals with indoor–outdoor correlations10.1016/j.buildenv.2018.11.034 ↗
39. Popescu, D., Stoican, F., Stamatescu, G., Ichim, L., and Dragana, C. (2020). Advanced UAV–WSN system for intelligent monitoring in precision agriculture. Sensors, 20.10.3390/s20030817 ↗
40. Cho, K., Cho, D., and Kim, T. (2021). Experimental analysis of CO2 concentration changes in an apartment using a residential heat recovery ventilator. Sustainability, 13.10.3390/su131810302 ↗
41. Gäbel, P., Koller, C., and Hertig, E. (2022). Development of air quality boxes based on low-cost sensor technology for ambient air quality monitoring. Sensors, 22.10.5194/egusphere-egu22-3719 ↗
42. Lin, B., Huangfu, Y., Lima, N., Jobson, B., Kirk, M., O’Keeffe, P., Pressley, S.N., Walden, V., Lamb, B., and Cook, D.J. (2017). Analyzing the relationship between human behavior and indoor air quality. J. Sens. Actuator Netw., 6.10.3390/jsan6030013 ↗
43. Cheng, W.H., Chen, Y.C., and Shih, S.Y. (2023). Volatile organic compound emissions from indoor fragrance diffusers. Atmosphere, 14.10.3390/atmos14061012 ↗
44. Do synthetic fragrances in personal care and household products impact indoor air quality and pose health risks?10.3390/jox13010010 ↗
45. Messan, S., Shahud, A., Anis, A., Kalam, R., Ali, S., and Aslam, M.I. (2022). Air-MIT: Air quality monitoring using Internet of Things. Eng. Proc., 20.10.3390/engproc2022020045 ↗
46. Benammar, M., Abdaoui, A., Ahmad, S.H., Touati, F., and Kadri, A. (2018). A modular IoT platform for real-time indoor air quality monitoring. Sensors, 18.10.3390/s18020581 ↗
47. Literature survey on how different factors influence human comfort in indoor environments10.1016/j.buildenv.2010.10.021 ↗
48. Carbon-integrated semiconductor photocatalysts for removal of volatile organic compounds in indoor environments10.1016/j.cej.2022.139436 ↗
49. Phytoremediation for the indoor environment: A state-of-the-art review10.1007/s11157-023-09644-5 ↗
50. Optimisation of permanent magnets of bioreactor magnetic coupling while preserving their efficiency
51. Suleiko, A., Vanags, J., Konuhova, M., Dubencovs, K., and Grigs, O. (2020). The application of novel magnetically coupled mixer drives in bioreactors of up to 15 m3. Biochem. Eng. J., 154.10.1016/j.bej.2019.107464 ↗
52. High-performance gas sensor array for indoor air quality monitoring: The role of Au nanoparticles on WO3, SnO2, and NiO-based gas sensors10.1039/D0TA08743B ↗
53. Indoor air quality in a domestic environment: Combined contribution of indoor and outdoor PM sources10.1016/j.buildenv.2021.108050 ↗
54. SEnviro: A sensorized platform proposal using open hardware and open standards10.3390/s150305555 ↗
55. Influence of CsCl addition on the nanostructured voids and optical properties of 80GeS2-20Ga2S3 glasses10.1016/j.optmat.2016.03.004 ↗
56. Air velocities inside domestic environments: An important parameter in the study of indoor air quality and climate10.1016/0160-4120(89)90074-3 ↗