journal article·2024-05-15Open access

Analysis and Applications of the Two Phases Closed Thermosyphon Technology in the Highways in Permafrost Regions: A Review

Shuai Du, Zeliang Ye

Applied Sciences· Volume 14· Issue 10

Abstract

Permafrost spans approximately 23–25% of the land in the northern hemisphere, primarily found in Russia, Canada, USA, and China. Numerous engineering projects, particularly those related to transportation, are situated within these permafrost regions. Due to the impact of highway construction and global warming, the permafrost beneath the infrastructure is deteriorating, leading to significant damage. Two phases closed thermosyphon (TPCT) is a widely accepted green countermeasure against the problem in permafrost regions. Although it has been applied to prevent permafrost degradation, their application presents significant challenges on account of the stronger endothermic action of asphalt pavement. This paper focused on a review of the thermosyphon technology and application in the permafrost. Moreover, the article highlighted the excellent working performance of the TPCT that improves the stability of the infrastructures and prevents it degrading due its excellent efficiency in terms of heat transfer. The industrial applications of the TPCT were also summarized, along with their limitations. Ultimately, the findings presented in this paper can offer crucial insights for future TPCT design and development in permafrost areas.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Climate change and permafrost · Smart Materials for Construction

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Northwest Institute of Eco-Environment and Resources, Chinese Academy of Sciences, Lanzhou 730000, China

University of Chinese Academy of Sciences, Beijing 100049, China

References (89)

Show source-provided references
1. A New 2010 Permafrost Distribution Map over the Qinghai–Tibet Plateau Based on Subregion Survey Maps: A Benchmark for Regional Permafrost Modeling10.5194/essd-15-3905-2023 ↗
2. Degrading Permafrost Puts Arctic Infrastructure at Risk by Mid-Century10.1038/s41467-018-07557-4 ↗
3. Impacts of Permafrost Degradation on Infrastructure10.1038/s43017-021-00247-8 ↗
4. Field and Numerical Studies on the Thermal Performance of Air Convection Embankments to Protect Side Slopes in Permafrost Environments10.1016/j.coldregions.2021.103325 ↗
5. Main Geotechnical Problems of Railways and Roads in Kriolitozone and Their Solutions10.1016/j.proeng.2017.05.111 ↗
6. Optimizing Embankment Structures in a Snowy Permafrost Region of the Pan-Arctic Based on a Coupled Numerical Model10.1016/j.trgeo.2022.100889 ↗
7. Application of the Cooling Measures in the Highway Roadbed in Permafrost Regions of the Qinghai-Tibet Plateau10.1016/j.coldregions.2024.104177 ↗
8. Wu, Q., Ma, W., Lai, Y., and Cheng, G. (2024). Permafrost Degradation Threatening the Qinghai—Xizang Railway. Engineering, S2095809924001292.10.1016/j.eng.2024.01.023 ↗
9. Adjusting Temperature Distribution under the South and North Slopes of Embankment in Permafrost Regions by the Ripped-Rock Revetment10.1016/j.coldregions.2004.04.003 ↗
10. McHattie, R., Mullin, A., and Liu, J. (2024, March 25). Evaluating the Need to Seal Thermal Cracks in Alaska’s Asphalt Concrete Pavements. Available online: https://scholarworks.alaska.edu/bitstream/handle/11122/7529/r.mchattie-et-al_evaluating-needto-seal-thermal-cracks_final-12.27.pdf?sequence=1.
11. Thermo-Seismic Performances of a Unilateral Two-Phase Closed Thermosyphon (TPCT) Embankment in Earthquake-Prone Permafrost Regions10.1016/j.trgeo.2020.100456 ↗
12. Evaluation of the Ground Heat Control Capacity of a Novel Air-L-Shaped TPCT-Ground (ALTG) Cooling System in Cold Regions10.1016/j.energy.2019.04.156 ↗
13. Evaluation of the Application Effect of the Inclined TPCTs on an Embankment with the Shady-Sunny Slope Effect in Permafrost Regions10.1016/j.coldregions.2023.103936 ↗
14. A Self-Adaption Horizontal Thermosyphon Technology in Uneven Thermal Control of Roadway Embankments in Sub-Arctic Permafrost Regions10.1016/j.trgeo.2021.100714 ↗
15. Laboratory Investigation of the Heat Transfer Characteristics of a Two-Phase Closed Thermosyphon10.1016/j.coldregions.2013.08.006 ↗
16. Countermeasures Combined with Thermosyphons against the Thermal Instability of High-Grade Highways in Permafrost Regions10.1016/j.ijheatmasstransfer.2019.119047 ↗
17. A Review of Experimental Studies on Cylindrical Two-Phase Closed Thermosyphon Using Refrigerant for Low-Temperature Applications10.1016/j.ijrefrig.2020.08.011 ↗
18. An Experimental Study of Two-Phase Closed Thermosyphons for Compact Solar Domestic Hot-Water Systems10.1016/j.solener.2003.02.001 ↗
19. Coupling Effect of Operational Factors on Heat Extraction from a Coal Pile Using a Two-Phase Closed Thermosyphon10.1016/j.energy.2021.122371 ↗
20. Numerical Simulation on the Performance of Thermosyphon Adopted to Mitigate Thaw Settlement of Embankment in Sandy Permafrost Zone10.1016/j.applthermaleng.2017.09.130 ↗
21. Reducing Heat Loss of Fluids in Heavy Oil Wellbore Using Two-Phase Closed Thermosyphon Sucker Rod10.1016/j.energy.2013.04.054 ↗
22. Experimental Investigation of the Thermal Performance of a Two-Phase Closed Thermosyphon at Different Operating Conditions10.1016/j.enbuild.2016.06.066 ↗
23. Wang, J., Lin, S., Tao, H., and Li, Y. (2023). Experiment Study on Dryout Characteristics and Thermal Resistance Analysis of Two-Phase Closed Thermosiphon (TPCT). Therm. Sci., 285.10.2298/TSCI230916285W ↗
24. Heat Pipe Heat Exchangers and Heat Sinks: Opportunities, Challenges, Applications, Analysis, and State of the Art10.1016/j.ijheatmasstransfer.2015.05.020 ↗
25. Heat Pipe Based Systems—Advances and Applications10.1016/j.energy.2017.04.028 ↗
26. Two-Phase Closed Thermosyphons: A Review of Studies and Solar Applications10.1016/j.rser.2015.09.002 ↗
27. Heat Transfer Performance of an Inclined Two-Phase Closed Thermosyphon10.1016/S0017-9310(83)80175-6 ↗
28. Experimental Investigation of a Two-Phase Closed Thermosyphon Charged with Hydrocarbon and Freon Refrigerants10.1016/j.apenergy.2017.06.100 ↗
29. Drage, J., and Brooks, H. (2012, January 17). Performance of a Thermopile (Long Thermopile) Foundation—50 Years Later. Proceedings of the Cold Regions Engineering 2012, Quebec City, QC, Canada.10.1061/9780784412473.036 ↗
30. Yarmak, E. (2015, January 23). Permafrost Foundations Thermally Stabilized Using Thermosyphons. Proceedings of the All Days, Copenhagen, Denmark.10.4043/25500-MS ↗
31. Correlations to Predict Heat Transfer Characteristics of an Inclined Closed Two-Phase Thermosyphon at Normal Operating Conditions10.1016/S1359-4311(99)00047-2 ↗
32. Condensation Heat Transfer Inside Vertical and Inclined Thermosyphons10.1115/1.2910634 ↗
33. Effect of Aspect Ratio and Filling Ratio on Thermal Performance of an Inclined Two-Phase Closed Thermosyphon
34. An Experimental Investigation on the Gravity Assisted Solar Heat Pipe under the Climatic Conditions of Tunisia10.1016/j.enconman.2012.06.009 ↗
35. Effect of Marangoni Condensation on the Heat Transfer Performance of Two-Phase Closed Thermosyphons10.1016/j.ijheatmasstransfer.2022.123669 ↗
36. Unsteady Experimental and Numerical Analysis of a Two-Phase Closed Thermosyphon at Different Filling Ratios10.1016/j.expthermflusci.2016.10.022 ↗
37. Experimental Investigation on Thermal-Electric Characteristics of Curved Thermosyphon-Thermoelectric Generator in Waste Heat Recovery of Coal Spontaneous Combustion10.1016/j.applthermaleng.2024.122638 ↗
38. Laboratory Investigation on the Cooling Effect of the Embankment with L-Shaped Thermosyphon and Crushed-Rock Revetment in Permafrost Regions10.1016/j.coldregions.2009.05.002 ↗
39. A Full-Scale Field Experiment to Evaluate the Cooling Performance of a Novel Composite Embankment in Permafrost Regions10.1016/j.ijheatmasstransfer.2015.12.067 ↗
40. Laboratory Investigation of the Efficiency Optimization of an Inclined Two-Phase Closed Thermosyphon in Ambient Cool Energy Utilization10.1016/j.renene.2018.08.078 ↗
41. Critical and Optimal Inclination Angles of Two-Phase Closed Thermosyphon under Different Operating Conditions10.1016/j.ijheatmasstransfer.2021.121540 ↗
42. Effect of Inclination Angle and Filling Ratio on Thermal Performance of a Two-Phase Closed Thermosyphon under Normal Operating Conditions10.1080/01457630601122997 ↗
43. Effect of Inclination Angle on the Heat Transfer Performance of a Two-Phase Closed Thermosyphon under Low-Temperature Conditions10.1061/(ASCE)CR.1943-5495.0000074 ↗
44. Experimental Study on the Startup and Heat Transfer Behaviors of a Two-Phase Closed Thermosyphon at Subzero Temperatures10.1016/j.ijheatmasstransfer.2021.122283 ↗
45. Feasibility Study on Use of Cellular Concrete for Air Convection Embankment on Permafrost Foundations in Fairbanks, Alaska10.1016/j.trgeo.2020.100317 ↗
46. Thermosyphons and Foundation Design in Cold Regions10.1016/0165-232X(88)90072-9 ↗
47. Performance of a Thermosyphon with a 37-Meter-Long, Horizontal Evaporator10.1016/0165-232X(92)90033-Q ↗
48. Remedying Embankment Thaw Settlement in a Warm Permafrost Region with Thermosyphons and Crushed Rock Revetment10.1139/t2012-058 ↗
49. Experimental Validation of Passive Permafrost Cooling Systems10.1016/j.coldregions.2007.09.002 ↗
50. Use of Two-Phase Heat Pipes with the Enlarged Heat-Exchange Surface for Thermal Stabilization of Permafrost Soils at the Bases of Structures10.1016/j.applthermaleng.2006.02.022 ↗
51. The Thermal Budget Evaluation of the Two-Phase Closed Thermosyphon Embankment of the Qinghai–Tibet Highway in Permafrost Regions10.1016/j.coldregions.2014.03.013 ↗
52. Crack Formation of a Highway Embankment Installed with Two-Phase Closed Thermosyphons in Permafrost Regions: Field Experiment and Geothermal Modelling10.1016/j.applthermaleng.2017.01.001 ↗
53. Numerical Simulation of Efficient Cooling by Coupled RR and TCPT on Railway Embankments in Permafrost Regions10.1016/j.applthermaleng.2018.01.070 ↗
54. The Thermal Effect of Heating Two-Phase Closed Thermosyphons on the High-Speed Railway Embankment in Seasonally Frozen Regions10.1016/j.applthermaleng.2018.06.061 ↗
55. Passively Cooled Railway Embankments for Use in Permafrost Areas10.1061/(ASCE)0887-381X(2003)17:3(119) ↗
56. Numerical Study of the Thermal Characteristics of a Shallow Tunnel Section with a Two-Phase Closed Thermosyphon Group in a Permafrost Region under Climate Warming10.1016/j.ijheatmasstransfer.2016.09.010 ↗
57. Thermal and Mechanical Response of Frozen Soils and Buried Pipeline Armed with Thermosyphons and Insulation Layer10.1007/s00231-023-03352-0 ↗
58. Two-Phase Closed Thermosyphon-Induced Frost Jacking of Piles and Foundation Instability in a Thawed Permafrost Area10.1007/s11069-023-06169-6 ↗
59. Laboratory Study on the Frost-Proof Performance of a Novel Embankment Dam in Seasonally Frozen Regions10.1016/j.jhydrol.2021.126769 ↗
60. Ding, L., Wang, W., Peng, B., Li, B., Li, B., and Sunden, B. (2023). A Modified Dynamic Lee Model for Two-Phase Closed Thermosyphon (TPCT) Simulation. Numer. Heat. Transf. Part. B Fundam., 1–15.10.1080/10407790.2023.2262114 ↗
61. Damage Analysis of the Characteristics and Development Process of Thermosyphon Embankment along the Qinghai-Tibet Highway10.1016/j.coldregions.2017.07.003 ↗
62. Laboratory Investigation on the Cooling Effect of Crushed-Rock Interlayer Embankment with Ventilated Ducts in Permafrost Regions10.1016/j.coldregions.2010.01.012 ↗
63. Hayley, D.W., Roggensack, W.D., Jubien, W.E., Johnson, P.V., Hayley, D.W., Roggensack, W.D., Jubien, W.E., and Johnson, P.V. (1983, January 18–22). Stabilization of Sinkholes on the Hudson Bay Railway. Proceedings of the Fourth International Conference on Permafrost, Fairbanks, AK, USA.
64. In-Situ Study on Cooling Effect of the Two-Phase Closed Thermosyphon and Insulation Combinational Embankment of the Qinghai–Tibet Railway10.1016/j.coldregions.2009.11.002 ↗
65. Observation Study on the Cooling Radius of a New Type of Heat Pipe in the Middle-Latitude Swampy Permafrost Regions
66. In-Situ Test Study on the Cooling Effect of Two-Phase Closed Thermosyphon in Marshy Permafrost Regions along the Chaidaer–Muli Railway, Qinghai Province, China10.1016/j.coldregions.2010.10.012 ↗
67. In-Situ Experimental and Numerical Investigation on the Cooling Effect of a Multi-Lane Embankment with Combined Crushed-Rock Interlayer and Ventilated Ducts in Permafrost Regions10.1016/j.coldregions.2014.05.003 ↗
68. Thermal Control Performance of the Embankment with L-Shaped Thermosyphons and Insulations along the Gonghe-Yushu Highway10.1016/j.coldregions.2021.103428 ↗
69. Thermal Performance and Heat Transfer Process of an Expressway Embankment with Horizontal-Thermosyphons in Permafrost Regions10.1016/j.coldregions.2023.103887 ↗
70. Performance Analyses of Two-Phase Closed Thermosyphons for Road Embankments in the High-Latitude Permafrost Regions10.1007/s11629-023-8215-2 ↗
71. Field Investigation on the Spatiotemporal Thermal-Deformation Characteristics of a Composite Embankment with Two-Phase Closed Thermosyphons on a Permafrost Slope10.1007/s11440-023-01878-5 ↗
72. Wang, G., Bi, J., Fan, Y., Zhu, L., Zhang, F., and Feng, D. (2022). Settlement Characteristic of Warm Permafrost Embankment with Two-Phase Closed Thermosyphons in Daxing’anling Mountains Region. Sustainability, 14.10.3390/su141912272 ↗
73. Cooling Performance of Two-Phase Closed Thermosyphons Installed at a Highway Embankment in Permafrost Regions10.1016/j.applthermaleng.2015.11.102 ↗
74. Numerical Analysis for Random Temperature Fields of Embankment in Cold Regions10.1007/s11430-007-2043-z ↗
75. Numerical Investigations and Engineering Applications on Freezing Expansion of Soil Restrained Two-Phase Closed Thermosyphons10.1016/S1290-0729(02)01324-8 ↗
76. Numerical Study on Cooling Characteristics of Two-Phase Closed Thermosyphon Embankment in Permafrost Regions10.1016/j.coldregions.2010.08.001 ↗
77. Geotemperature Control Performance of Two-Phase Closed Thermosyphons in the Shady and Sunny Slopes of an Embankment in a Permafrost Region10.1016/j.applthermaleng.2016.10.143 ↗
78. Evaluation on the Stability of Expressway Embankment Combined with L-Shaped Thermosyphons and Insulation Boards in Warm and Ice-Rich Permafrost Regions10.1016/j.trgeo.2021.100633 ↗
79. Numerical Evaluation for Cooling Performance of a Composite Measure on Expressway Embankment with Shady and Sunny Slopes in Permafrost Regions10.1016/j.energy.2022.123194 ↗
80. Numerical Evaluation of the Cooling Performance of a Composite L-Shaped Two-Phase Closed Thermosyphon (LTPCT) Technique in Permafrost Regions10.1016/j.solener.2018.11.001 ↗
81. Numerical Optimization of the Installing Position for the L-Shaped TPCT in a Permafrost Embankment Based on the Spatial Heat Control10.1016/j.solener.2021.06.044 ↗
82. A Review and Comparative Study of the Investigations on Micro Heat Pipes10.1002/er.1285 ↗
83. Determination of Operation Envelopes for Closed, Two-Phase Thermosyphons10.1016/S0017-9310(98)00212-9 ↗
84. Determination of the Operation Range of a Vertical Two-Phase Closed Thermosyphon10.1007/s00231-011-0954-x ↗
85. Entrainment Limits in Heat Pipes10.2514/3.61190 ↗
86. Heat Transfer Analysis of an Inclined Two-Phase Closed Thermosyphon10.1115/1.2836287 ↗
87. Experimental Investigation of Geyser Boiling in an Annular Two-Phase Closed Thermosyphon10.1016/0017-9310(95)90019-5 ↗
88. Experimental Investigation of Effective Parameters and Correlation of Geyser Boiling in a Two-Phase Closed Thermosyphon10.1016/j.applthermaleng.2009.09.012 ↗
89. The Micro-Structural Studies of Ni-BaTiO3 Nanocomposite Films by TEM and EELS10.1007/s11595-011-0333-4 ↗