journal article·2023-03-22Open access

Numerical Investigation of the Relationship between Anastomosis Angle and Hemodynamics in Ridged Spiral Flow Bypass Grafts

Jhon Jasper Apan, Lemmuel Tayo, Jaime Honra

Applied Sciences· Volume 13· Issue 6

Abstract

Bypass graft failures are linked to hemodynamic disturbances resulting from poor design. Several studies have tried to improve graft patency by modifying conventional graft designs. One strategy being employed is to induce spiral flow in bypass grafts using an internal ridge which has been proposed to optimize blood flow. However, there is still no study focusing on how the anastomosis angle can affect the hemodynamics of such a design despite its huge influence on local flow fields. To fill this gap, we aimed to understand and optimize the relationship between anastomosis angle and ridged spiral flow bypass graft hemodynamics to minimize disturbances and prolong graft patency. Steady-state, non-Newtonian computational fluid dynamics (CFD) analysis of a distal, end-to-side anastomosis between a ridged graft and idealized femoral artery was used to determine the anastomosis angle that would yield the least hemodynamic disturbances. Transient, pulsatile, non-Newtonian CFD analysis between a conventional and ridged graft at the optimal angle was performed to determine if such a design has an advantage over conventional designs. The results revealed that smaller anastomosis angles tend to optimize graft performance by the reduction in the pressure drop, recirculation, and areas in the host artery affected by abnormally high shear stresses. It was also confirmed that the modified design outperformed conventional bypass grafts due to the increased shear stress generated which is said to have atheroprotective benefits. The findings of the study may be taken into consideration in the design of bypass grafts to prevent their failure due to hemodynamic disturbances associated with conventional designs and highlight the importance of understanding and optimizing the relationship among different geometric properties in designing long-lasting bypass grafts.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Coronary Interventions and Diagnostics · Cardiac and Coronary Surgery Techniques · Peripheral Artery Disease Management

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Mechanical and Manufacturing Engineering, Mapúa University, Manila 1002, Philippines

School of Chemical, Biological, and Materials Engineering and Sciences, Mapúa University, Manila 1002, Philippines

Department of Biology, School of Medicine and Health Sciences, Mapúa University, Makati 1200, Philippines

Funding

Mapúa University

References (55)

Show source-provided references
1. Aaronson, P.I., Ward, J.T., and Connolly, M.J. (2012). The Cardiovascular System at a Glance, Wiley-Blackwell. [4th ed.].
2. The Tissue-Engineered Vascular Graft—Past, Present, and Future10.1089/ten.teb.2015.0100 ↗
3. Neointimal Hyperplasia
4. Optimal graft diameter: Effect of wall shear stress on vascular healing10.1016/0741-5214(89)90449-7 ↗
5. Flow Effects on Coagulation and Thrombosis10.1161/01.ATV.0000229658.76797.30 ↗
6. Hemodynamic Shear Stress and Its Role in Atherosclerosis10.1001/jama.282.21.2035 ↗
7. Local Hemodynamics of the Vascular Access for Hemodialysis10.1159/000205522 ↗
8. Competitive flow and anastomosis angle influence on bypass hemodynamics in unsteady flow conditions10.1063/1.4992166 ↗
9. Computational study on the haemodynamic and mechanical performance of electrospun polyurethane dialysis grafts10.1007/s10237-019-01242-1 ↗
10. Micromechanics and strength of agglomerates produced by spray drying10.1016/j.jciso.2022.100068 ↗
11. Response of shear-activated nanotherapeutic particles in a clot-obstructed blood vessel by CFD-DEM simulations10.1002/cjce.24502 ↗
12. Recent advances in mechanical force-responsive drug delivery systems10.1039/D2NA00420H ↗
13. Two-dimensional flow quantitative MRI of aortic arch blood flow patterns: Effect of age, sex, and presence of carotid atheromatous disease on prevalence of spiral blood flow10.1002/jmri.10341 ↗
14. Helical flow: A means to identify unstable plaques and a new direction for the design of vascular grafts and stents10.1016/j.atherosclerosis.2020.03.002 ↗
15. The mechanics of spiral flow: Enhanced washout and transport10.1111/aor.13520 ↗
16. Effect of aortic spiral blood flow on wall shear stress in stenosed left main coronary arteries with varying take-off angle, stenosis severity and eccentricity10.1007/s12206-018-0751-2 ↗
17. Effects of non Newtonian spiral blood flow through arterial stenosis10.1063/1.4958373 ↗
18. Early Results of Using the Spiral Flow AV Graft: Is It a Breakthrough Solution to a Difficult Problem?10.1016/j.jvs.2015.06.110 ↗
19. Hybrid nanofluid (MoS2–SiO2/water) flow with viscous dissipation and Ohmic heating on an irregular variably thick convex/concave-shaped sheet in a porous medium10.1002/htj.22330 ↗
20. Experimental Investigation on Thermal Performance Characteristics of Rotating Packed Bed10.1080/08916152.2022.2027576 ↗
21. A multiresolution wavelet optimised finite-difference method for simulation of thermal regenerator10.1016/j.tsep.2020.100669 ↗
22. Cattaneo–Christov heat flux model in Darcy–Forchheimer radiative flow of MoS2–SiO2/kerosene oil between two parallel rotating disks10.1007/s10973-022-11248-0 ↗
23. Analysis and preparation of rotational flow mechanism of artificial blood vessel with spiral folds on inner wall10.1007/s10237-018-1092-x ↗
24. Optimisation of a Novel Spiral-Inducing Bypass Graft Using Computational Fluid Dynamics10.1038/s41598-017-01930-x ↗
25. Kabinejadian, F., McElroy, M., Ruiz-Soler, A., Leo, H.L., Slevin, M.A., Badimon, L., and Keshmiri, A. (2016). Numerical Assessment of Novel Helical/Spiral Grafts with Improved Hemodynamics for Distal Graft Anastomoses. PLoS ONE, 11.10.1371/journal.pone.0165892 ↗
26. The effect of anastomotic angle and diameter ratio on flow field in the distal end-to-side anastomosis10.1177/0954411919894410 ↗
27. The Anastomotic Angle of Hemodialysis Arteriovenous Fistula Is Associated with Flow Disturbance at the Venous Stenosis Location on Angiography10.3389/fbioe.2020.00846 ↗
28. Tailoring of arteriovenous graft-to-vein anastomosis angle to attenuate pathological flow fields10.1038/s41598-021-90813-3 ↗
29. 3D numerical model of blood flow in the coronary artery bypass graft during no pulse and pulse situations: Effects of an anastomotic angle and characteristics of fluid10.1007/s12206-018-0851-z ↗
30. Dey, S., Ibtida, T., Roy, C.K., and Sakib, N. (2020, January 5–7). Effect of Varying Anastomosis Angles for Non-Newtonian Pulsatile Blood Flow through Artery Bypass Graft Models: An LES Study. Proceedings of the 2020 IEEE Region 10 Symposium (TENSYMP 2020), Dhaka, Bangladesh.10.1109/TENSYMP50017.2020.9230640 ↗
31. Magnetic resonance imaging measurement of blood volume flow in peripheral arteries in healthy subjects10.1016/S0741-5214(03)00706-7 ↗
32. The liver, a functionalized vascular structure10.1038/s41598-020-73208-8 ↗
33. Inumaru, J., Hara, S., and Hasegawa, T. (2021). Advances in Power Boilers, Elsevier.
34. Modelling and simulation of multiphase flow applicable to processes in oil and gas in-dustry10.1515/cppm-2017-0066 ↗
35. Zhang, J., Wang, D., Wang, W., and Zhu, Z. (2022). Numerical Investigation and Optimization of the Flow Characteristics of Bend Pipe with Different Bending Angles. Processes, 10.10.3390/pr10081510 ↗
36. Constructal design of an arterial bypass graft10.1002/htj.21693 ↗
37. Pulsatile flow through an idealized arterial bypass graft: An application of the constructal design method10.1007/s40430-021-03048-8 ↗
38. ANSYS Inc. (2017). ANSYS CFD-Post User’s Guide, Swanson Analysis Systems.
39. A mathematical model to evaluate hemodynamic effects of the graft anastomosis in coronary surgery10.5114/kitp.2019.86366 ↗
40. Wall Shear Stress: Theoretical Considerations and Methods of Measurement10.1016/j.pcad.2006.11.001 ↗
41. Low Wall Shear Stress Is Associated with Saphenous Vein Graft Stenosis in Patients with Coronary Artery Bypass Grafting10.1007/s12265-020-09982-7 ↗
42. Kim, J.T., Kim, H., and Ryou, H.S. (2021). Hemodynamic Analysis on the Anastomosis Angle in Arteriovenous Graft Using Multiphase Blood Model. Appl. Sci., 11.10.3390/app11178160 ↗
43. Flow recirculation zone length and shear rate are differentially affected by stenosis severity in human coronary arteries10.1152/ajpheart.00428.2012 ↗
44. Numerical investigation on flow fields in partially stenosed artery with complete bypass graft: An in vitro study10.1016/j.icheatmasstransfer.2007.03.010 ↗
45. Flow patterns and preferred sites of intimal thickening in bypass-grafted arteries
46. Flow mediated fibrin thrombus formation in an endothelium-lined model of arterial branching10.1016/0049-3848(94)90219-4 ↗
47. Coronary artery bypass grafting hemodynamics and anastomosis design: A biomedical engineering review10.1186/1475-925X-12-129 ↗
48. The Effect of Angle and Flow Rate Upon Hemodynamics in Distal Vascular Graft Anastomoses: An In Vitro Model Study10.1115/1.2895427 ↗
49. The anastomosis angle does change the flow fields at vascular end-to-side anastomoses in vivo10.1016/S0741-5214(95)70288-1 ↗
50. Secondary Flow in Peripheral Vascular Prosthetic Grafts Using Vector Doppler Imaging10.1016/j.ultrasmedbio.2013.07.014 ↗
51. Malvè, M., Finet, G., Lagache, M., Coppel, R., Pettigrew, R.I., and Ohayon, J. (2021). Biomechanics of Coronary Atherosclerotic Plaque: From Model to Patient, Academic Press.
52. A Longitudinal Study of Remodeling in a Revised Peripheral Artery Bypass Graft Using 3D Ultrasound Imaging and Computational Hemodynamics10.1115/1.4003622 ↗
53. Low wall shear stress predicts subsequent development of wall hypertrophy in lower limb bypass grafts10.1016/j.artres.2009.01.001 ↗
54. Fluid-Dynamic Optimal Design of Helical Vascular Graft for Stenotic Disturbed Flow10.1371/journal.pone.0111047 ↗
55. Helical type coronary bypass graft performance: Experimental investigations10.3233/BME-151337 ↗