Accuracy, Time, and Comfort of Different Intraoral Scanners: An In Vivo Comparison Study
Source abstract
Abstract
Background: The purpose of this study was to compare the accuracy of three different intraoral scanners (IOSs) and to evaluate the patients’ experience. Methods: Thirty subjects were scanned with three different IOSs (TRIOS Color®, iTero Element 5D®, and iTero Lumina®): a sample of 90 maxillary casts was collected. The inclusion criteria were permanent dentition, absence of defects during the dental impression, and complete record of the palatal vault. After the scanning procedure, patients were asked to answer a questionnaire (10 answers, scale from 1 to 10) to compare their experiences with iTero Element and iTero Lumina in the scanning procedure. Results: Differences were recorded in the upper central incisor region (f-ratio of 4.186 for Mesiodistal 1.1 and f-ratio of 4.222 for Mesiodistal 2.1, p < 0.05), while intercanine width Upper 13–23 showed the smallest f-ratio (0.226) when compared to the other results, followed by Mesiodistal 1.4 (0.433). Patients reported more comfort, less pain, decreased duration, and a better technology visualization of the impression with iTero Lumina. No significant differences concerning dryness of the mouth and gag reflex were found. Conclusions: The examined IOSs offer comparable accuracy in capturing dental arch dimensions. The interviewed patients expressed an overall preference for digital impressions performed with iTero Lumina, linked to increased comfort, painless practice, and a better technology visualization of the impression.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Temporomandibular Joint Disorders · Orthodontics and Dentofacial Orthopedics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Health Sciences, UniCamillus-Saint Camillus International Medical University, 00131 Rome, Italy
References (22)
Show source-provided references
1. The dimensional accuracy of 12 impression material and die stone combinations
2. Accuracy of Intraoral Scanners: A Systematic Review of Influencing Factors
3. Conventional versus Digital Dental Impression Techniques: What Is the Future? An Umbrella Review10.3390/prosthesis5030060 ↗
4. Yuzbasioglu, E., Kurt, H., Turunc, R., and Bilir, H. (2014). Comparison of digital and conventional impression techniques: Evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes. BMC Oral Health, 14.10.1186/1472-6831-14-10 ↗
5. Accuracy of intraoral scanners versus traditional impressions: A rapid umbrella review10.1016/j.jebdp.2022.101719 ↗
6. Digital Impressions Versus Conventional Impressions in Prosthodontics: A Systematic Review
7. Róth, I., Czigola, A., Fehér, D., Vitai, V., Joós-Kovács, G.L., Hermann, P., Borbély, J., and Vecsei, B. (2022). Digital intraoral scanner devices: A validation study based on common evaluation criteria. BMC Oral Health, 22.10.1186/s12903-022-02176-4 ↗
8. Saccomanno, S., Saran, S., Vanella, V., Mastrapasqua, R.F., Raffaelli, L., and Levrini, L. (2022). The Potential of Digital Impression in Orthodontics. Dent. J., 10.10.3390/dj10080147 ↗
9. Winkler, J., and Gkanditis, N. (2020). Trueness and precision of intraoral scanners in the maxillary dental arch: An in vivo analysis. Sci. Rep., 10.10.1038/s41598-020-58075-7 ↗
10. Nedelcu, R., Olsson, P., Nystrom, I., and Thor, A. (2018). Finish line distinctness and accuracy in 7 intraoral scanners versus conventional impression: An in vitro descriptive comparison. BMC Oral Health, 18.10.1186/s12903-018-0489-3 ↗
11. Accuracy, reliability, and efficiency of intraoral scanners for full-arch impressions: A systematic review of the clinical evidence10.1093/ejo/cjv077 ↗
12. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions10.1016/j.prosdent.2015.09.011 ↗
13. Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition10.4047/jap.2015.7.6.460 ↗
14. Kamimura, E., Tanaka, S., Takaba, M., Tachi, K., and Baba, K. (2017). In vivo evaluation of inter-operator reproducibility of digital dental and conventional impression techniques. PLoS ONE, 12.10.1371/journal.pone.0179188 ↗
15. Impact of digital intraoral scan strategies on the impression accuracy using the TRIOS Pod scanner
16. An overview on the veracity of intraoral digital scanning system and utilization of iTero scanner for analyzing orthodontic study models both in-vivo and ex-vivo10.4103/njcp.njcp_698_19 ↗
17. (2024). iTero LuminaTM Intraoral Scanner: User Manual, January 2024, Align Technology, Inc.
18. Analyzing and interpreting data from likert-type scales10.4300/JGME-5-4-18 ↗
19. Comparing the accuracy of six intraoral scanners on prepared teeth and effect of scanning sequence10.4047/jap.2020.12.5.299 ↗
20. Will digital impressions eliminate the current problems with conventional impressions?10.14219/jada.archive.2008.0258 ↗
21. A new method for the computer-aided evaluation of three-dimensional changes in gypsum materials10.1016/S0109-5641(02)00013-1 ↗
22. Comparison of digital intraoral scanners and alginate impressions: Time and patient satisfaction10.1016/j.ajodo.2017.08.017 ↗