The Impact of Contact Force on Signal Quality Indices in Photoplethysmography Measurements
Source abstract
Abstract
Photoplethysmography (PPG) is widely used to assess cardiovascular health. Yet, its effectiveness is often hindered by external factors like contact force (CF), which significantly affects the accuracy and reliability of measurements. This study investigates how variations in the CF at the index fingertips influence six signal quality indices (SQIs)—including the perfusion index, skewness, kurtosis, entropy, zero-crossing rate, and relative power—using data from 11 healthy participants. Our analysis of normalized CF values reveals that lower CF ranges (0.2 to 0.4) may be optimal for extracting information about perfusion and blood flow. However, they may not be the best range to capture all the physiological details within the PPG pulse. In contrast, higher CF ranges (0.4 to 0.6) enable capturing more complex signals that could be physiologically representative. The findings underscore the necessity of considering viscoelastic tissue properties and individual biomechanical differences, advocating for both the normalization of CF for improved cross-subject comparison and personalized CF calibration to adapt PPG devices to diverse populations. These strategies ensure measurement reliability and consistency, thereby advancing the accuracy of cardiac and vascular assessments. Our study offers guidelines for adjusting the CF levels to balance signal detail and perfusion quality, customized to meet specific analytical requirements, with direct implications for both clinical and research environments.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Non-Invasive Vital Sign Monitoring · Hemodynamic Monitoring and Therapy · Heart Rate Variability and Autonomic Control
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium
Department of Biomedical Engineering, Universidad de Oriente, Santiago de Cuba 90500, Cuba
Centre of Medical Biophysics, Universidad de Oriente, Santiago de Cuba 90500, Cuba
Funding
VUB · Belgian Development Cooperation · OZR4103 VUB project funding · FWO-Flanders FWOSB106 Ph.D. grant · Innoviris-Brussels
References (64)
Show source-provided references
1. Photoplethysmography and its application in clinical physiological measurement10.1088/0967-3334/28/3/R01 ↗
2. Chatterjee, S., Patel, Z., Thaha, M.A., and Kyriacou, P.A. (2020). In silico and in vivo investigations using an endocavitary photoplethysmography sensor for tissue viability monitoring. J. Biomed. Opt., 25.10.1117/1.JBO.25.2.027001 ↗
3. Han, D., Bashar, S.K., Lázaro, J., Mohagheghian, F., Peitzsch, A., Nishita, N., Ding, E., Dickson, E.L., DiMezza, D., and Scott, J. (2022). A real-time PPG peak detection method for accurate determination of heart rate during sinus rhythm and cardiac arrhythmia. Biosensors, 12.10.3390/bios12020082 ↗
4. Detection and classification of sleep apnea and hypopnea using PPG and SpO2 signals10.1109/TBME.2020.3028041 ↗
5. Assessing hemodynamics from the photoplethysmogram to gain insights into vascular age: A review from VascAgeNet10.1152/ajpheart.00392.2021 ↗
6. The use of multi-site photoplethysmography (PPG) as a screening tool for coronary arterial disease and atherosclerosis10.1088/1361-6579/abad48 ↗
7. The analysis of PPG morphology: Investigating the effects of aging on arterial compliance10.2478/v10048-012-0036-3 ↗
8. Yadav, U., Abbas, S.N., and Hatzinakos, D. (2018, January 20–23). Evaluation of PPG biometrics for authentication in different states. Proceedings of the 2018 International Conference on Biometrics (ICB), Gold Coast, Australia.10.1109/ICB2018.2018.00049 ↗
9. The use of photoplethysmography in the assessment of mental health: Scoping review10.2196/40163 ↗
10. Arterial stiffness, endothelial function and microcirculatory reactivity in healthy young males10.1111/j.1475-097X.2008.00807.x ↗
11. Mizeva, I., Di Maria, C., Frick, P., Podtaev, S., and Allen, J. (2015). Quantifying the correlation between photoplethysmography and laser Doppler flowmetry microvascular low-frequency oscillations. J. Biomed. Opt., 20.10.1117/1.JBO.20.3.037007 ↗
12. Allen, J., and Chen, F. (2022). Low-frequency variability in photoplethysmography and autonomic function assessment. Photoplethysmography, Elsevier.10.1016/B978-0-12-823374-0.00008-6 ↗
13. Peripheral vasomotor activity assessment using a continuous wavelet analysis on webcam photoplethysmographic signals10.3233/BME-161606 ↗
14. Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditions10.1088/0967-3334/31/9/015 ↗
15. Pulse rate variability in cardiovascular health: A review on its applications and relationship with heart rate variability10.1088/1361-6579/ab998c ↗
16. A real-time PPG quality assessment approach for healthcare Internet-of-Things10.1016/j.procs.2019.04.074 ↗
17. Park, J., Seok, H.S., Kim, S.S., and Shin, H. (2022). Photoplethysmogram Analysis and Applications: An Integrative Review. Front. Physiol., 12.10.3389/fphys.2021.808451 ↗
18. EEG spectral entropy, heart rate, photoplethysmography and motor responses to skin incision during sevoflurane anaesthesia10.1111/j.1399-6576.2005.00654.x ↗
19. Wang, L., Pickwell-MacPherson, E., Liang, Y., and Zhang, Y.T. (2009, January 2–6). Noninvasive cardiac output estimation using a novel photoplethysmogram index. Proceedings of the 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Minneapolis, MN, USA.10.1109/IEMBS.2009.5333091 ↗
20. Assessment of vasoactive agents and vascular aging by the second derivative of photoplethysmogram waveform10.1161/01.HYP.32.2.365 ↗
21. Přibil, J., Přibilová, A., and Frollo, I. (2020). Comparative measurement of the PPG signal on different human body positions by sensors working in reflection and transmission modes. Eng. Proc., 2.10.3390/ecsa-7-08204 ↗
22. Kim, K.B., and Baek, H.J. (2023). Photoplethysmography in wearable devices: A comprehensive review of technological advances, current challenges, and future directions. Electronics, 12.10.3390/electronics12132923 ↗
23. Lujan, M.R., Perez-Pozuelo, I., and Grandner, M.A. (2021). Past, present, and future of multisensory wearable technology to monitor sleep and circadian rhythms. Front. Digit. Health, 3.10.3389/fdgth.2021.721919 ↗
24. Detection and removal of motion artifacts in PPG signals10.1007/s11036-019-01323-6 ↗
25. Time to consider the contact force during photoplethysmography measurement during pediatric anesthesia: A prospective, nonrandomized interventional study10.1111/pan.13415 ↗
26. May, J.M., Mejía-Mejía, E., Nomoni, M., Budidha, K., Choi, C., and Kyriacou, P.A. (2021). Effects of Contact Pressure in Reflectance Photoplethysmography in an In Vitro Tissue-Vessel Phantom. Sensors, 21.10.3390/s21248421 ↗
27. PPG Sensor Contact Pressure Should be Taken into Account for Cuff-Less Blood Pressure Measurement10.1109/TBME.2020.2976989 ↗
28. Ultraflexible near-infrared organic photodetectors for conformal photoplethysmogram sensors10.1002/adma.201802359 ↗
29. Hartmann, V., Liu, H., Chen, F., Qiu, Q., Hughes, S., and Zheng, D. (2019). Quantitative comparison of photoplethysmographic waveform characteristics: Effect of measurement site. Front. Physiol., 10.10.3389/fphys.2019.00198 ↗
30. The effect of contacting force on photoplethysmographic signals10.1088/0967-3334/25/5/020 ↗
31. Influence of Contact Forces on Wrist Photo plethysmography-Prestudy for a Wearable Patient Monitor10.1515/BMT.2004.005 ↗
32. Liu, C., Correia, R.G., Ballaji, H.K., Korposh, S., Hayes-Gill, B.R., and Morgan, S.P. (2018). Optical fibre-based pulse oximetry sensor with contact force detection. Sensors, 18.10.3390/s18113632 ↗
33. Scardulla, F., D’Acquisto, L., Colombarini, R., Hu, S., Pasta, S., and Bellavia, D. (2020). A study on the effect of contact pressure during physical activity on photoplethysmographic heart rate measurements. Sensors, 20.10.3390/s20185052 ↗
34. Evaluation of key design parameters for mitigating motion artefact in the mobile reflectance PPG signal to improve estimation of arterial oxygenation10.1088/1361-6579/aacfe5 ↗
35. Lambert Cause, J., Solé Morillo, Á., da Silva, B., García-Naranjo, J.C., and Stiens, J. (2024). Evaluating Vascular Depth-Dependent Changes in Multi-Wavelength PPG Signals Due to Contact Force. Sensors, 24.10.3390/s24092692 ↗
36. Sun, X., Yang, P., and Zhang, Y.T. (September, January 28). Assessment of photoplethysmogram signal quality using morphology integrated with temporal information approach. Proceedings of the 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, San Diego, CA, USA.
37. Ovadia-Blechman, Z., Hauptman, Y., Rabin, N., Wiezman, G., Hoffer, O., Gertz, S.D., Gavish, B., and Gavish, L. (2023). Morphological features of the photoplethysmographic signal: A new approach to characterize the microcirculatory response to photobiomodulation. Front. Physiol., 14.10.3389/fphys.2023.1175470 ↗
38. Elgendi, M. (2020). PPG Signal Analysis: An Introduction Using MATLAB, CRC Press.10.1201/9780429449581 ↗
39. Elgendi, M. (2016). Optimal signal quality index for photoplethysmogram signals. Bioengineering, 3.10.3390/bioengineering3040021 ↗
40. Photoplethysmogram signal quality estimation using repeated Gaussian filters and cross-correlation10.1088/0967-3334/33/10/1617 ↗
41. A High-Efficiency and Real-Time Method for Quality Evaluation of PPG Signals10.1088/1757-899X/711/1/012100 ↗
42. Machine-Aided PPG Signal Quality Assessment (SQA) for Multi-Mode Physiological Signal Monitoring10.1145/3587256 ↗
43. Selvaraj, N., Mendelson, Y., Shelley, K.H., Silverman, D.G., and Chon, K.H. (September, January 30). Statistical approach for the detection of motion/noise artifacts in Photoplethysmogram. Proceedings of the 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Boston, MA, USA.10.1109/IEMBS.2011.6091232 ↗
44. A robust motion artifact detection algorithm for accurate detection of heart rates from photoplethysmographic signals using time–frequency spectral features10.1109/JBHI.2016.2612059 ↗
45. Orphanidou, C., and Orphanidou, C. (2018). Signal quality assessment in physiological monitoring: Requirements, practices and future directions. Signal Quality Assessment in Physiological Monitoring: State of the Art and Practical Considerations, Springer.10.1007/978-3-319-68415-4 ↗
46. Zanelli, S., El Yacoubi, M.A., Hallab, M., and Ammi, M. (2021, January 1–5). Transfer learning of CNN-based signal quality assessment from clinical to non-clinical PPG signals. Proceedings of the 2021 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), Virtual.10.1109/EMBC46164.2021.9629640 ↗
47. Sivanjaneyulu, Y., Manikandan, M.S., and Boppu, S. (2022, January 29–30). Cnn based ppg signal quality assessment using raw ppg signal for energy-efficient ppg analysis devices in internet of medical things. Proceedings of the 2022 International Conference on Artificial Intelligence of Things (ICAIoT), Istanbul, Turkey.10.1109/ICAIoT57170.2022.10121884 ↗
48. Chatterjee, T., Ghosh, A., and Sarkar, S. (2022, January 11–15). Signal quality assessment of photoplethysmogram signals using quantum pattern recognition technique and lightweight cnn module. Proceedings of the 2022 44th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), Glasgow, UK.10.1109/EMBC48229.2022.9871494 ↗
49. Yan, R., Ding, C., Xiao, R., Fedorov, A., Lee, R.J., Nahab, F., and Hu, X. (2024). SQUWA: Signal Quality Aware DNN Architecture for Enhanced Accuracy in Atrial Fibrillation Detection from Noisy PPG Signals. arXiv.
50. Gao, H., Wu, X., Shi, C., Gao, Q., and Geng, J. (2021, January 19–25). A LSTM-based realtime signal quality assessment for photoplethysmogram and remote photoplethysmogram. Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, Virtual.10.1109/CVPRW53098.2021.00424 ↗
51. Chowdhury, S.S., Hasan, M.S., and Sharmin, R. (2019, January 17–20). Robust heart rate estimation from ppg signals with intense motion artifacts using cascade of adaptive filter and recurrent neural network. Proceedings of the TENCON 2019–2019 IEEE Region 10 Conference (TENCON), Kochi, India.10.1109/TENCON.2019.8929692 ↗
52. Castiñeira Pérez, D. (2022, October 21). Desig, Implementation and Validation of n Atrial Fibrillation Screening System through PPG Signals and Machine Learning Techniques. Ph.D. Thesis, 2020. Available online: http://castor.det.uvigo.es:8080/xmlui/bitstream/handle/123456789/497/TFM%20Diego%20Casti%C3%B1eira%20P%C3%A9rez.pdf?sequence=1&isAllowed=y.
53. Sinus or not: A new beat detection algorithm based on a pulse morphology quality index to extract normal sinus rhythm beats from wrist-worn photoplethysmography recordings10.1088/1361-6579/aae7f8 ↗
54. Papini, G.B., Fonseca, P., Aubert, X.L., Overeem, S., Bergmans, J.W., and Vullings, R. (2017, January 11–15). Photoplethysmography beat detection and pulse morphology quality assessment for signal reliability estimation. Proceedings of the 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Jeju Island, Republic of Korea.10.1109/EMBC.2017.8036776 ↗
55. Karlen, W. (2021). CapnoBase InVivo Dataset, Borealis.
56. Karlen, W. (2021). CSL Pulse Oximetry Artifact Labels, Borealis.
57. Moody, B., Moody, G., Villarroel, M., Clifford, G., and Silva, I. (2020). MIMIC-III Waveform Database Matched Subset. PhysioNet.
58. Hair, J.F., Hult, G.T.M., Ringle, C.M., Sarstedt, M., Danks, N.P., Ray, S., Hair, J.F., Hult, G.T.M., Ringle, C.M., and Sarstedt, M. (2021). An introduction to structural equation modeling. Partial Least Squares Structural Equation Modeling (PLS-SEM) Using R: A Workbook, Springer.10.1007/978-3-030-80519-7 ↗
59. Mejia-Mejia, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P.A., and Charlton, P.H. (2022). Photoplethysmography signal processing and synthesis. Photoplethysmography, Elsevier.10.1016/B978-0-12-823374-0.00015-3 ↗
60. Elshal, M.M., Hasanin, A.M., Mostafa, M., and Gamal, R.M. (2021). Plethysmographic peripheral perfusion index: Could it be a new vital sign?. Front. Med., 8.10.3389/fmed.2021.651909 ↗
61. Kluyver, T., Ragan-Kelley, B., Pérez, F., Granger, B., Bussonnier, M., Frederic, J., Kelley, K., Hamrick, J., Grout, J., and Corlay, S. (2016). Jupyter Notebooks—A publishing format for reproducible computational workflows. Positioning and Power in Academic Publishing: Players, Agents and Agendas, IOS Press.
62. A contact-force regulated photoplethysmography (PPG) platform10.1063/1.5020914 ↗
63. Spigulis, J., Gailite, L., Erts, R., and Lihachev, A. (2007, January 17–21). Contact probe pressure effects in skin multi-spectral photoplethysmography. Proceedings of the European Conference on Biomedical Optics (Optica Publishing Group), Munich, Germany.10.1364/ECBO.2007.6628_55 ↗
64. Sirkiä, J.P., Panula, T., and Kaisti, M. (2021, January 13–15). The Effects of External Pressure on Multi-Wavelength Photoplethysmography Signals. Proceedings of the 2021 Computing in Cardiology (CinC), Brno, Czech Republic.10.23919/CinC53138.2021.9662771 ↗