A cross strip (XS) anode detector is a photon-counting imaging detector with high spatial resolution. However, due to the Poisson distribution characteristics of the photons emitted by the target, photons with a small time interval will cause signal superposition and resolution degradation. This is particularly significant at a high photon count rate. The key link that restricts the counting rate of the XS detector is the electronic system. In this paper, we propose a new electronic signal processing system scheme using a digital trapezoidal shaping filter instead of a traditional Gaussian shaping filter, which enables the detector to maintain a high resolution at high count rates. In order to verify the feasibility of the scheme, the relationship between shaping errors and shaping parameters is studied. Furthermore, the relationship between spatial resolution and photon-counting rate at different noise levels is revealed by numerical simulation. The results show that the detector can achieve a spatial resolution of <50 μm at a photon count rate of >6 MHz for 1000 e RMS noise.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Optical Sensing Technologies · Photocathodes and Microchannel Plates · CCD and CMOS Imaging Sensors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
University of Chinese Academy of Sciences, Beijing 100049, China
Funding
National Natural Science Foundation of China
References (28)
Show source-provided references
1. Microspectroscopy and imaging using a delay line detector in time-of-flight photoemission microscopy10.1063/1.1405781 ↗
2. Tremsin, A.S., Siegmund, O., and Hull, J.S. (November, January 29). High Resolution Photon Counting Detection System for Advanced Inelastic X-ray Scattering Studies. Proceedings of the 2006 IEEE Nuclear Science Symposium Conference Record, San Diego, CA, USA.10.1109/NSSMIC.2006.355959 ↗
3. Count rate and dynamic range of an x-ray imaging system with mcp detector10.1016/j.nima.2005.09.033 ↗
4. A large area mcp detector for x-ray imaging10.1016/S0168-9002(97)81164-3 ↗
5. Wide-field auroral imager onboard the Fengyun satellite
6. UV MCP Detectors for WSO-UV: Cross Strip Anode and Readout Electronics10.1109/TNS.2013.2248096 ↗
7. Conti, L., Barnstedt, J., Buntrock, S., Diebold, S., and Schaadt, D.M. (2020, January 14–18). Microchannel-Plate Detector Development for Ultraviolet Missions. Proceedings of the SPIE Conference, Astronomical Telescopes and Instrumentation, Online.10.1117/12.2560663 ↗
8. MCP detector development for uv space missions10.1007/s10509-018-3283-4 ↗
9. Next generation microchannel plate detector technologies for UV astronomy
10. High-performance microchannel plate detectors for UV/visible astronomy10.1016/j.nima.2004.03.018 ↗
11. Tremsin, A.S., Siegmund, O., Vallerga, J.V., and Hull, J.S. (2006). Novel high resolution readout for uv and x-ray photon counting detectors with microchannel plates. Proc. SPIE–Int. Soc. Opt. Eng., 6276.10.1117/12.674401 ↗
12. High speed multichannel charge sensitive data acquisition system with self-triggered event timing10.1109/TNS.2009.2015302 ↗
13. Jiang, Z., and Ni, Q. (2022). Design and Performance of Photon Imaging Detector Based on Cross-Strip Anode with Charge Induction. Appl. Sci., 12.10.3390/app12178471 ↗
14. A fast, low power and low noise charge sensitive amplifier asic for a uv imaging single photon detector10.1088/1748-0221/12/04/T04007 ↗
15. Vallerga, J., Mcphate, J., Tremsin, A., Siegmund, O., and Varner, G. (2016). SPIE Astronomical Telescopes + Instrumentation. Space Telescopes and Instrumentation 2016: Ultraviolet to Gamma Ray, Edinburgh, UK, SPIE.
16. Low power readout electronics for a uv mcp detector with cross strip anode10.1088/1748-0221/9/03/C03059 ↗
17. Characterisation of low power readout electronics for a UV microchannel plate detector with cross-strip readout
18. Optimization for spatial resolution and count rate of a far ultraviolet photon-counting imaging detector based on induced charge position-sensitive anode10.3788/AOS201434.0804001 ↗
19. Siegmund, O., Tremsin, A.S., and Vallerga, J.V. (2007). High Performance Cross-Strip Detector Technologies for Space Astrophysics, IEEE Nuclear Science Symposium Conference Record.10.1109/NSSMIC.2007.4436595 ↗
20. Vallerga, J., Raffanti, R., Cooney, M., Cumming, H., Varner, G., and Seljak, A. (2014). Cross Strip Anode Readouts for Large Format, Photon Counting Microchannel Plate Detectors: Developing Flight Qualified Prototypes of the Detector and Electronics, International Society for Optics and Photonics.10.1117/12.2058412 ↗
21. Siegmund, O., Mcphate, J., Curtis, T., Darling, N., and Ertley, C. (2020). X-ray, Optical, and Infrared Detectors for Astronomy IX, SPIE.
22. Dead-time effects in photon counting distributions10.1016/0168-9002(90)90327-3 ↗
23. Applications Expand for Photon Counting
24. Spatial charge cloud size of microchannel plates10.1063/1.2472595 ↗
25. Curved focal plane extreme ultraviolet detector array for a EUV camera on CHANG E lander10.1364/OE.23.030755 ↗
26. Digital techniques for real-time pulse shaping in radiation measurements10.1016/0168-9002(94)91652-7 ↗
27. Digital synthesis of pulse shapes in real time for high resolution radiation spectroscopy10.1016/0168-9002(94)91011-1 ↗
28. Centroiding algorithms and spatial resolution of photon counting detectors with cross-strip anodes