journal article·2024-05-27Open access

Re-Evaluating the Long-Term Efficacy of Semi-Rigid Fixation Using a Nitinol Spring Rod in Lumbar Surgery: A Retrospective Study on an Effective Alternative for Reducing Adjacent Segment Disease

Hyun-Jun Jang, Bong-Ju Moon, Dong-Kyu Chin

Applied Sciences· Volume 14· Issue 11

Abstract

Adjacent segment disease (ASD) is a prevalent complication following lumbar fusion surgery, representing a significant challenge in spinal surgery. This study aimed to assess the long-term outcomes of Nitinol spring rod semi-rigid fixation, a potential alternative to traditional rigid fixation, in reducing the incidence of ASD. This retrospective case study evaluated 89 patients who underwent lumbar or lumbosacral surgeries using a combination of Bioflex® (a Nitinol spring rod dynamic stabilization system) and an interbody cage over 10 years of follow-up. The fusion status, adjacent segment disc height, mechanical complications, and re-operation rates were analyzed. The cohort had a median follow-up duration of 13.0 years. All patients achieved solid fusion at the final follow-up visit. One patient underwent revision surgery for clinical ASD (1.1%), and no patients required revision surgery due to mechanical problems. Radiological evidence of ASD was observed in 16.9% of the patients. This study’s findings suggest that semi-rigid fixation using Bioflex with an interbody cage is a possibly effective treatment strategy to prevent ASD. The technique potentially reduces the risk of ASD by allowing a degree of movement at the surgical site.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Spine and Intervertebral Disc Pathology · Spinal Fractures and Fixation Techniques · Medical Imaging and Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Neurosurgery, Spine and Spinal Cord Institute, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul 06273, Republic of Korea

References (31)

Show source-provided references
1. Lumbar Spine Fusion: What Is the Evidence?10.1111/imj.14120 ↗
2. Adjacent Segment Disease Followinglumbar/Thoracolumbar Fusion with Pedicle Screw Instrumentation: A Minimum 5-Year Follow-Up10.1097/BRS.0b013e31814b2d8e ↗
3. A Prospective Randomised Study on the Long-Term Effect of Lumbar Fusion on Adjacent Disc Degeneration10.1007/s00586-009-0947-3 ↗
4. Adjacent Segment Degeneration in the Lumbar Spine10.2106/00004623-200407000-00020 ↗
5. Lumbar Adjacent Segment Degeneration and Disease after Arthrodesis and Total Disc Arthroplasty10.1097/BRS.0b013e31817bb956 ↗
6. Update on the Evidence for Adjacent Segment Degeneration and Disease10.1016/j.spinee.2012.12.009 ↗
7. Correlation between Sagittal Plane Changes and Adjacent Segment Degeneration Following Lumbar Spine Fusion10.1007/s005860000239 ↗
8. A Descriptive Study on the Adjacent Segment Degeneration Related Signs Following a Lumbar Fusion Procedure10.21037/jss-21-26 ↗
9. Incidence and Prevalence of Surgery at Segments Adjacent to a Previous Posterior Lumbar Arthrodesis10.1016/j.spinee.2010.09.026 ↗
10. Pelvic Incidence–Lumbar Lordosis Mismatch Is Predisposed to Adjacent Segment Degeneration after Single-Level Anterior Lumbar Interbody Fusion: A Retrospective Case-Control Study10.14245/ns.2244934.467 ↗
11. Adjacent Segment Degeneration
12. Adjacent Segment Disease10.3928/01477447-20140728-08 ↗
13. Biomechanical Changes of Adjacent and Fixed Segments through Cortical Bone Trajectory Screw Fixation Versus Traditional Trajectory Screw Fixation in the Lumbar Spine: A Finite Element Analysis10.1016/j.wneu.2021.04.061 ↗
14. Cao, L., Liu, Y., Mei, W., Xu, J., and Zhan, S. (2020). Biomechanical Changes of Degenerated Adjacent Segment and Intact Lumbar Spine after Lumbosacral Topping-Off Surgery: A Three-Dimensional Finite Element Analysis. BMC Musculoskelet. Disord., 21.10.1186/s12891-020-3128-5 ↗
15. Radiological Adjacent-Segment Degeneration in L4–5 Spondylolisthesis: Comparison between Dynamic Stabilization and Minimally Invasive Transforaminal Lumbar Interbody Fusion10.3171/2018.1.SPINE17993 ↗
16. Biomechanical Evaluation of Pedicle Screw-Based Dynamic Stabilization Devices for the Lumbar Spine: A Systematic Review10.1016/S1935-9810(08)70035-5 ↗
17. Clinical and Biomechanical Researches of Polyetheretherketone (Peek) Rods for Semi-Rigid Lumbar Fusion: A Systematic Review10.1007/s10143-016-0763-2 ↗
18. The Bioflex System as a Dynamic Stabilization Device: Does It Preserve Lumbar Motion?10.3340/jkns.2009.46.5.431 ↗
19. The Thickness of Human Vertebral Cortical Bone and Its Changes in Aging and Osteoporosis: A Histomorphometric Analysis of the Complete Spinal Column from Thirty-Seven Autopsy Specimens10.1359/jbmr.1997.12.1.89 ↗
20. Lin, B., Yu, H., Chen, Z., Huang, Z., and Zhang, W. (2016). Comparison of the Peek Cage and an Autologous Cage Made from the Lumbar Spinous Process and Laminae in Posterior Lumbar Interbody Fusion. BMC Musculoskelet. Disord., 17.10.1186/s12891-016-1237-y ↗
21. Does Radiographic Osteoarthritis Correlate with Flexibility of the Lumbar Spine?10.1111/j.1532-5415.1994.tb01748.x ↗
22. Mid-Range Outcomes in 64 Consecutive Cases of Multilevel Fusion for Degenerative Diseases of the Lumbar Spine
23. The Surgical Outcome of Multilevel Anterior Cervical Discectomy and Fusion in Myelopathic Elderly and Younger Patients10.1038/s41598-022-08243-8 ↗
24. Disc Height Reduction in Adjacent Segments and Clinical Outcome 10 Years after Lumbar 360 Fusion10.1007/s00586-007-0515-7 ↗
25. Nitinol Spring Rod Dynamic Stabilization System and Nitinol Memory Loops in Surgical Treatment for Lumbar Disc Disorders: Short-Term Follow Up
26. Nitinol Memory Rods Versus Titanium Rods: A Biomechanical Comparison of Posterior Spinal Instrumentation in a Synthetic Corpectomy Model10.1177/2192568220902401 ↗
27. Long-Term Failure of Dynamic Rods Used in Full Dynamic Stabilization10.4274/jtss.galenos.2023.68077 ↗
28. Proximal Junctional Kyphosis or Failure after Adult Spinal Deformity Surgery-Review of Risk Factors and Its Prevention10.14245/ns.2346476.238 ↗
29. Soft Landing Technique as a Possible Prevention Strategy for Proximal Junctional Failure Following Adult Spinal Deformity Surgery10.21037/jss-20-622 ↗
30. Ligament Augmentation with Mersilene Tape Reduces the Rates of Proximal Junctional Kyphosis and Failure in Adult Spinal Deformity10.14245/ns.2142420.210 ↗
31. The Comprehensive Biomechanics and Load-Sharing of Semirigid Peek and Semirigid Posterior Dynamic Stabilization Systems10.1155/2013/745610 ↗