journal article·2023-11-23Open access

Verification of Industrial Worker Walking Efficiency with Wearable Hip Exoskeleton

Yunhee Chang, Jungsun Kang, Bora Jeong, Gyoosuk Kim, Bokman Lim, Byungjune Choi, Younbaek Lee

Applied Sciences· Volume 13· Issue 23

Abstract

In highly mobile workplaces, wearable walking-assistant devices reduce muscle fatigue in workers’ lower extremities and increase energy efficiency. In our study, we verify this following the development of an ultralight wearable hip exoskeleton for industrial workers. Ten healthy male adults participated in this study, and their muscle activity, muscle fatigue, and energy expenditure were compared with and without a device while walking on a treadmill and going up stairs. While walking on a treadmill with the assistive device, muscle fatigue in the gastrocnemius decreased by 79.5%, and oxygen uptake and energy expenditure per minute decreased by 7.9% and 7.4%, respectively. While climbing stairs with the assistive device, muscle fatigue of the tibialis anterior decreased by 83.5%, average muscle activity of the rectus femoris, semitendinosus, and gastrocnemius muscles decreased significantly, and oxygen uptake and energy expenditure decreased by 14% and 12.9% per minute, respectively. We confirm that an ultralight wearable hip exoskeleton helps the wearer reduce lower-limb muscle fatigue and use metabolic energy more efficiently. The results of this study are intended as basic data to expand the use of ultralight wearable hip exoskeletons at industrial sites and to improve device performance.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Prosthetics and Rehabilitation Robotics · Stroke Rehabilitation and Recovery · Muscle activation and electromyography studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Korea Compensation and Welfare, Rehabilitation Engineering Research Institute, Incheon 21417, Republic of Korea

Wirobotics Incorporation, Yongin 16942, Republic of Korea

Funding

Korea Institute For Robot Industry Advancement

References (40)

Show source-provided references
1. Exoskeletons—A review of industrial applications10.1108/IR-05-2018-0109 ↗
2. The effect of a passive trunk exoskeleton on metabolic costs during lifting and walking10.1080/00140139.2019.1602288 ↗
3. An ergonomic assessment tool for evaluating the effect of back exoskeletons on injury risk10.1016/j.apergo.2021.103619 ↗
4. Fatigue recognition in overhead assembly based on a soft robotic exosuit for worker assistance10.1016/j.cirp.2021.04.034 ↗
5. Shi, Y., Dong, W., Lin, W., and Gao, Y. (2022). Soft wearable exoskeleton: Development status and technical challenges. Sensors, 22.10.3390/s22197584 ↗
6. John, S.W., Murakami, K., Komatsu, M., and Adachi, S. (2017, January 17–20). Cross-wire assist suit concept, for mobile and lightweight multiple degree of freedom hip assistance. Proceedings of the 2017 International Conference on Rehabilitation Robotics (ICORR), London, UK.10.1109/ICORR.2017.8009278 ↗
7. Experimental evaluation of energy efficiency for a soft wearable robotic suit10.1109/TNSRE.2016.2613886 ↗
8. Chen, L., Chen, C., Wang, Z., Ye, X., Liu, Y., and Wu, X. (2021). A novel lightweight wearable soft exosuit for reducing the metabolic rate and muscle fatigue. Biosensors, 11.10.3390/bios11070215 ↗
9. Reducing the energy cost of walking with low assistance levels through optimized hip flexion assistance from a soft exosuit10.1038/s41598-022-14784-9 ↗
10. Underactuated soft hip exosuit based on adaptive oscillators to assist human locomotion10.1109/LRA.2021.3136240 ↗
11. Haufe, F.L., Wolf, P., Riener, R., and Grimmer, M. (2020). Biomechanical effects of passive hip springs during walking. J. Biomech., 98.10.1016/j.jbiomech.2019.109432 ↗
12. Reducing the energy cost of running using a lightweight, low-profile elastic exosuit10.1186/s12984-021-00928-x ↗
13. A wearable hip assist robot can improve gait function and cardiopulmonary metabolic efficiency in elderly adults
14. Kim, D.S., Lee, H.J., Lee, S.H., Chang, W.H., Jang, J., Choi, B.O., Ryu, G.H., and Kim, Y.H. (2018). A wearable hip-assist robot reduces the cardiopulmonary metabolic energy expenditure during stair ascent in elderly adults: A pilot cross-sectional study. BMC Geriatr., 18.10.1186/s12877-018-0921-1 ↗
15. Exercise with a wearable hip-assist robot improved physical function and walking efficiency in older adults10.1038/s41598-023-32335-8 ↗
16. Soft robotic suits: State of the art, core technologies, and open challenges10.1109/TRO.2021.3084466 ↗
17. van Dijk, W., van der Kooij, H., and Hekman, E. (July, January 29). A passive exoskeleton with artificial tendons: Design and experimental evaluation. Proceedings of the 2011 IEEE International Conference on Rehabilitation Robotics, Zurich, Switzerland.10.1109/ICORR.2011.5975470 ↗
18. Connecting a human limb to an exoskeleton
19. Pesenti, M., Antonietti, A., Gandolla, M., and Pedrocchi, A. (2021). Towards a functional performance validation standard for industrial low-back exoskeletons: State of the art review. Sensors, 21.10.3390/s21030808 ↗
20. The mechanisms and mechanical energy of human gait initiation from the lower-limb joint level perspective10.1038/s41598-021-01694-5 ↗
21. Parametric delayed output feedback control for versatile human-exoskeleton interactions during walking and running10.1109/LRA.2023.3284351 ↗
22. Effects of walking speed, strength and range of motion on gait stability in healthy older adults10.1016/j.jbiomech.2008.08.002 ↗
23. The relationship between EMG median frequency and low frequency band amplitude changes at different levels of muscle capacity10.1016/S0268-0033(02)00033-5 ↗
24. Maximal oxygen uptake10.1056/NEJM197105062841809 ↗
25. Indirect calorimetry: History, technology, and application10.3389/fped.2018.00257 ↗
26. EMG-based validation of musculo-skeletal models for gait analysis10.1080/10255842.2013.815878 ↗
27. Indices of muscle fatigue10.1016/1050-6411(91)90023-X ↗
28. Reproducibility evaluation of gross and net walking efficiency in children with cerebral palsy10.1017/S0012162207000114.x ↗
29. Ueber die Bedeutung der verschiedenen Nährstoffe als Erzeuger der Muskelkraft10.1007/BF01746509 ↗
30. Gait biomechanics, spatial and temporal characteristics, and the energy cost of walking in older adults with impaired mobility10.2522/ptj.20090316 ↗
31. Conduction velocity and EMG power spectrum changes in fatigue of sustained maximal efforts10.1152/jappl.1981.51.5.1300 ↗
32. Analysis and simulation of changes in EMG amplitude during high-level fatiguing contractions10.1109/TBME.2003.816078 ↗
33. Effects of resistance training on older adults10.2165/00007256-200434050-00005 ↗
34. Human-in-the-loop optimization of exoskeleton assistance during walking10.1126/science.aal5054 ↗
35. Biomechanical and physiological evaluation of multi-joint assistance with soft exosuits10.1109/TNSRE.2016.2523250 ↗
36. Young, A.J., Foss, J., Gannon, H., and Ferris, D.P. (2017). Influence of power delivery timing on the energetics and biomechanics of humans wearing a hip exoskeleton. Front. Bioeng. Biotechnol., 5.10.3389/fbioe.2017.00004 ↗
37. Harper, N.G., Wilken, J.M., and Neptune, R.R. (2018). Muscle function and coordination of stair ascent. J. Biomech. Eng., 140.10.1115/1.4040772 ↗
38. Development of a soft exosuit system for walking assistance during stair ascent and descent10.1007/s12555-019-0584-5 ↗
39. Metabolic cost of daily activities and effect of mobility impairment in older adults10.1111/j.1532-5415.2011.03655.x ↗
40. Energy expenditures for activities of daily living in Korean young adults: A preliminary study10.5535/arm.2016.40.4.725 ↗