Dynamic Response Analysis of Mega-Sub Isolated Structures under Multiaxial Earthquakes
Source abstract
Abstract
With the use of seismic isolation techniques on mega-sub structures, several scholars have carried out research on them. However, little research has been carried out on mega-sub isolated structures under multiaxial earthquakes. There have been instances in actual engineering where the peak vertical acceleration exceeded the horizontal direction, and the vertical seismic component will also amplify the dynamic response of the structure in the horizontal direction, so in practice, it is necessary to consider the influence of the vertical component of the earthquake on the structure. To investigate the dynamic response of mega-sub isolated structures under unidirectional earthquake and coupled earthquake, this paper used numerical methods to analyze the influences of the horizontal and vertical damping ratio of the isolation layer, the horizontal and vertical frequency ratio of the main substructure, and the mass ratio of the main substructure on the acceleration and displacement of the main and substructure. The optimum parameter values are finally achieved by analytical calculations, which provide a basis for further optimization and practical design of the structure. Finally, the collision between the main and sub-structures in the mega-sub isolated structure was simulated, and the influences of the peak ground motion, main and subframe spacing, vertical seismic component, and sub-structure height on the collision force and acceleration were analyzed. It was shown that the conflict of the main and sub-structures generates instantaneous, large collision forces, which also instantaneously amplify the acceleration and base shear force response, which should be avoided in practical engineering.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Seismic Performance and Analysis · Vibration Control and Rheological Fluids · Seismic and Structural Analysis of Tall Buildings
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Civil Engineering, Fuzhou University, Fuzhou 350116, China
School of Resource Engineering, Longyan University, Longyan 364012, China
School of Ecological Environment and Urban Construction, Fujian University of Technology, Fuzhou 350118, China
Funding
National Natural Science Foundation of China · Science and Technology Planning Project of Fujian · Science and Technology Planning Project of Fuzhou
References (39)
Show source-provided references
1. Szolomicki, J., and Golasz-Szolomicka, H. (2019). Technological advances and trends in modern high-rise buildings. Buildings, 9.10.3390/buildings9090193 ↗
2. Research developments in vibration control of structures using passive tuned mass dampers10.1016/j.arcontrol.2017.09.015 ↗
3. Using seismic isolation columns for retrofitting buildings with soft stories10.1002/tal.451 ↗
4. Earthquake-resilient design of base isolated buildings with TMD at basement: Application to a case study10.1016/j.soildyn.2018.06.022 ↗
5. Base-isolated structures with selective controlled semi-active friction dampers10.1002/tal.527 ↗
6. Analysis of factors influencing dynamic characteristics of mega-structure
7. An efficient structural analysis of super tall mega frame buildings using a multi-level condensation method10.3130/jaabe.11.343 ↗
8. Vibration control of tall buildings using mega subconfiguration10.1061/(ASCE)0733-9399(1995)121:10(1082) ↗
9. Vibration control of super tall buildings subjected to wind loads10.1016/S0020-7462(96)00094-7 ↗
10. Mita, A., and Kaneko, M. (1996). Post-Earthquake Rehabilitation and Reconstruction, Pergamon.
11. A method of estimating the parameters of tuned mass dampers for seismic applications10.1002/(SICI)1096-9845(199706)26:6<617::AID-EQE664>3.0.CO;2-Z ↗
12. Research of Earthquake Resistance Performance on the Mega-Sub Controlled Structure10.4028/www.scientific.net/AMM.353-356.2196 ↗
13. Vibration control parameters investigation of the mega-sub controlled structure system (MSCSS)10.12989/eas.2013.5.2.225 ↗
14. Design, optimization and nonlinear response control analysis of the mega sub-controlled structural system (MSCSS) under earthquake action10.1142/S179343112050013X ↗
15. Response control analysis of a new mega-sub controlled structural system (MSCSS) under seismic excitation10.1002/tal.1935 ↗
16. Partial mass isolation in tall buildings10.1002/(SICI)1096-9845(199801)27:1<49::AID-EQE718>3.0.CO;2-J ↗
17. De Silva, C.W. (2005). Vibration and Shock Handbook, CRC Press.10.1201/9781420039894 ↗
18. An experimental study on seismic responses of multifunctional vibration-absorption reinforced concrete megaframe structures10.1002/eqe.324 ↗
19. The aseismic capability and shaking table experiment of mega-frame structures
20. Mechanism analysis and parameter optimization of mega-sub-isolation system
21. Experimental investigation of mega-sub isolation structure10.1002/tal.1360 ↗
22. Comparison of the seismic performance of a partial mass isolation technique with conventional TMD and base-isolation systems under broad-band and narrow-band excitations10.1016/j.engstruct.2017.12.018 ↗
23. Kim, S.J. (2008). Seismic Assessment of RC Structures Considering Vertical Ground Motion, UIUC.
24. Seismic isolation and fuzzy vibration control of shell structure subjected to vertical seismic forces
25. Shaking table and pseudodynamic tests for the evaluation of the seismic performance of base-isolated structures10.1016/S0141-0296(97)00211-3 ↗
26. Preliminary analysis of vertical ground motion characteristics of Wenchuan earthquake
27. Full-scale shaking table test of a base-isolated medical facility subjected to vertical motions10.1002/eqe.2305 ↗
28. Computational simulation of slab vibration and horizontal-vertical coupling in a full-scale test bed subjected to 3D shaking at E-Defense10.1002/eqe.2973 ↗
29. Multi-dimensional seismic response analysis of three-dimensional seismic-isolation mega-sub structure
30. Experimental tests and numerical modeling of full-scale unbonded fiber reinforced elastomeric isolators (UFREIs) under bidirectional excitation10.1016/j.engstruct.2022.115118 ↗
31. High activity earthquake swarm event monitoring and impact analysis on underground high energy physics research facilities10.3390/en15103705 ↗
32. Tian, Y.J. (2002). Damping Principle and Optimization Design Method of Multifunctional Damping Structure of Mega Frame, Southeast University. (In Chinese).
33. Analysis of vibration damping mechanism and damping effect of multifunctional vibration-damping structural system with mega frame
34. Seismic analysis of giant frame structures
35. Seismic response time analysis method
36. Design of High Damping HNBR Isolation Bearings for Bridges
37. Experimental study on mechanical properties of high damping rubber bearing model10.1088/1755-1315/61/1/012105 ↗
38. Falborski, T., and Jankowski, R. (2017). Experimental study on effectiveness of a prototype seismic isolation system made of polymeric bearings. Appl. Sci., 7.10.3390/app7080808 ↗
39. Multi-directional base isolation system for coupled horizontal and vertical seismic excitations10.1080/13632469.2020.1713925 ↗