journal article·2023-10-18Open access

Orthodontic Relapse after Fixed or Removable Retention Devices: A Systematic Review

Francesco Inchingolo, Angelo Michele Inchingolo, Sabino Ceci, Vincenzo Carpentiere, Mariagrazia Garibaldi, Lilla Riccaldo, Daniela Di Venere, Alessio Danilo Inchingolo, Giuseppina Malcangi, Andrea Palermo, Francesco Carlo Tartaglia, Gianna Dipalma

Applied Sciences· Volume 13· Issue 20

Abstract

Retention constitutes a fundamental phase of orthodontic treatment, of which the patient must be made aware from the outset. Retention, which can be fixed or movable, has the task of maintaining over time and stabilising the results obtained during treatment. This study assessed the efficacy of using removable restraints versus fixed solutions for maintaining long-term outcomes. A comprehensive search across major databases—Pubmed, Web of Science, Scopus—used ‘relapse’ and ‘orthodontic’ as keywords to gather articles on relapse discussions. The primary focus was relapsed cases in post-fixed orthodontic therapy. Both fixed and removable retainer systems prove effective in preserving orthodontic achievements. While fixed devices require regular wire integrity checks, mobile devices require patient compliance, proper usage, and a recommended wear time. Studies indicate that fixed retainers are generally successful, with relapse rates varying based on the retainer type. Full-time use of removable devices surpasses night-only wear. Vacuum-formed and Hawley retainers offer similar effectiveness. Fixed retainers excel in long-term alignment stability, whereas removable ones have higher failure rates yet remain beneficial.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Temporomandibular Joint Disorders · Facial Rejuvenation and Surgery Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy

College of Medicine and Dentistry, Birmingham B4 6BN, UK

Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20072 Pieve Emanuele, Italy

References (59)

Show source-provided references
1. Effects of Fixed vs Removable Orthodontic Retainers on Stability and Periodontal Health: 4-Year Follow-up of a Randomized Controlled Trial10.1016/j.ajodo.2018.01.007 ↗
2. The Crisis in Orthodontia Part I. 2. Tissue Changes during Retention. Skogsborg’s Septotomy10.1016/S0097-0522(34)90166-0 ↗
3. Cytokine Gene Polymorphisms Associate with Microbiogical Agents in Periodontal Disease: Our Experience10.7150/ijms.6962 ↗
4. Toward a Perspective on Orthodontic Retention?10.1016/S0889-5406(98)70261-6 ↗
5. Mummolo, S., Nota, A., Marchetti, E., Padricelli, G., and Marzo, G. (2016). The 3D Tele Motion Tracking for the Orthodontic Facial Analysis. Biomed. Res. Int., 2016.10.1155/2016/4932136 ↗
6. Analyze My Face
7. An Approach to Rotational Relapse10.1016/0002-9416(81)90198-6 ↗
8. Clinical and Histologic Observations on Tooth Movement during and after Orthodontic Treatment10.1016/0002-9416(67)90118-2 ↗
9. Stress Distribution and Collagen Remodeling of Periodontal Ligament During Orthodontic Tooth Movement10.3389/fphar.2019.01263 ↗
10. Cellular Response within the Periodontal Ligament on Application of Orthodontic Forces10.4103/0972-124X.107468 ↗
11. Orthodontic Treatment of an Unerupted Mandibular Canine Tooth in a Patient with Mixed Dentition: A Case Report10.1186/s13256-016-0923-6 ↗
12. Short-Term Postorthodontic Changes in the Absence of Retention10.2319/010210-7.1 ↗
13. Equilibrium Theory Revisited: Factors Influencing Position of the Teeth
14. Stability and Relapse of Dental Arch Alignment10.1179/bjo.17.3.235 ↗
15. Platelet-Rich Plasma (PRP) and Platelet-Rich Fibrin (PRF) in Human Cell Cultures: Growth Factor Release and Contradictory Results10.1016/j.tripleo.2010.05.059 ↗
16. Relapse of Orthodontic Treatment Results: Growth as an Etiologic Factor
17. Saccomanno, S., Quinzi, V., D’Andrea, N., Albani, A., Coceani Paskay, L., and Marzo, G. (2021). Traumatic Events and Eagle Syndrome: Is There Any Correlation? A Systematic Review. Healthcare, 9.10.3390/healthcare9070825 ↗
18. Comparison of Retention Characteristics of Clear Bow Hawley’s and Vacuum Formed Retainers—A Randomized Controlled Trial10.4103/jofs.jofs_259_22 ↗
19. Anterior Cruciate Ligament Reconstruction and Determination of Tunnel Size and Graft Obliquity
20. Unilateral Superior Condylar Neck Fracture with Dislocation in a Child Treated with an Acrylic Splint in the Upper Arch for Functional Repositioning of the Mandible10.1080/08869634.2016.1203560 ↗
21. Fixed Orthodontic Retainers: A Review10.5152/TurkJOrthod.2019.18080 ↗
22. Temporomandibular Joint Disk Displacement: Etiology, Diagnosis, Imaging, and Therapeutic Approaches10.1097/SCS.0000000000009103 ↗
23. Prevalence of Temporomandibular Disorders (TMD) in Pregnancy: A Systematic Review with Meta-analysis10.1111/joor.13458 ↗
24. PRISMA 2020 Explanation and Elaboration: Updated Guidance and Exemplars for Reporting Systematic Reviews10.1136/bmj.n160 ↗
25. A Prospective Randomized Controlled Trial on the Comparative Clinical Efficiency and Hygiene of a Ceramic Inter Locking Retainer and a Flexible Spiral Wire Bonded Retainer10.4103/ijdr.IJDR_1050_20 ↗
26. A Randomized Controlled Trial of Three Orthodontic Retention Methods in Class I Four Premolar Extraction Cases—Stability after 2 Years in Retention10.1111/ocr.12011 ↗
27. Bonded versus Vacuum-Formed Retainers: A Randomized Controlled Trial. Part 1: Stability, Retainer Survival, and Patient Satisfaction Outcomes after 12 Months10.1093/ejo/cjx058 ↗
28. CAD/CAM Nitinol Bonded Retainer versus a Chairside Rectangular-Chain Bonded Retainer: A Multicentre Randomised Controlled Trial10.1177/14653125221118935 ↗
29. Clinical Comparison between Multi-Stranded Wires and Single Strand Ribbon Wires Used for Lingual Fixed Retainers10.1186/s40510-020-00315-7 ↗
30. Comparative Assessment of Relapse and Failure between CAD/CAM Stainless Steel and Standard Stainless Steel Fixed Retainers in Orthodontic Retention Patients:A Randomized Controlled Trial10.2319/121720-1015.1 ↗
31. Comparing Orthodontic Relapse of Mandibular Anterior Teeth with Traditional Bonded versus Magnetic Retainers after 2 Years of Retention10.1016/j.ejwf.2017.04.003 ↗
32. Comparing the Effects of CAD/CAM Nickel-Titanium Lingual Retainers on Teeth Stability and Periodontal Health with Conventional Fixed and Removable Retainers: A Randomized Clinical Trial10.1111/ocr.12425 ↗
33. Comparison of 2 Different Wear Protocols of Vacuum-Formed Retainers with Respect to the Conventional Parameters and 3-Dimensional Superimpositional Analysis10.1016/j.ajodo.2021.09.023 ↗
34. Comparison of Post-Treatment Changes with and without Retention in Adolescents Treated for Maxillary Impacted Canines—A Randomized Controlled Trial10.1093/ejo/cjaa010 ↗
35. Comparison of Two Retention Appliances with Respect to Clinical Effectiveness10.5152/TurkJOrthod.2019.18045 ↗
36. Does Quality of Orthodontic Treatment Outcome Influence Post-Treatment Stability? A Retrospective Study Investigating Short-Term Stability 2 Years after Orthodontic Treatment with Fixed Appliances and in the Presence of Fixed Retainers10.1111/ocr.12545 ↗
37. Effectiveness of Two Types of Fixed Lingual Retainers in Preventing Mandibular Incisor Relapse10.29271/jcpsp.2020.03.282 ↗
38. Effects of Different Lingual Retainers on Periodontal Health and Stability10.2319/110220-904.1 ↗
39. Cernei, E.R., Dascalu, C.G., Anistoroaei, D., Golovcencu, L., Sodor-Botezatu, A., and Zegan, G. (2022, January 17–18). Efficiency of Two Different Types of Upper Bonded Retainers. Proceedings of the 2022 E-Health and Bioengineering Conference (EHB), Iasi, Romania.10.1109/EHB55594.2022.9991581 ↗
40. Evaluation of 3 Retention Protocols Using the American Board of Orthodontics Cast and Radiograph Evaluation10.1016/j.ajodo.2013.02.022 ↗
41. Evaluation of Long-Term Stability of Curve of Spee Levelled with Continuous Archwires in Two Different Retention Protocol10.25259/APOS_22_2021 ↗
42. Evaluation of Relapse with Thermoplastic Retainers Equipped with Microsensors10.2319/072221-578.1 ↗
43. Five-Year Postretention Outcomes of Three Retention Methods--a Randomized Controlled Trial10.1093/ejo/cju063 ↗
44. Long-Term Effectiveness of Maxillary and Mandibular Bonded Orthodontic Retainers
45. Long-Term Stability of Maxillary Anterior Alignment in Non-Extraction Cases10.1590/S2176-94512013000300009 ↗
46. Relapse of Anterior Crowding 3 and 33 Years Postretention10.1016/j.ajodo.2017.05.022 ↗
47. Post-Treatment Changes in Permanent Retention10.1007/s00056-016-0054-0 ↗
48. Mandibular Incisor Alignment in Untreated Subjects Compared with Long-Term Changes after Orthodontic Treatment with or without Retainers10.1016/j.ajodo.2018.03.025 ↗
49. Postretention Stability after Orthodontic Closure of Maxillary Interincisor Diastemas10.1590/1678-775720130472 ↗
50. Maxillary Anterior Alignment Stability in Class I and Class II Malocclusions Treated with or without Extraction10.2319/112614-847.1 ↗
51. Mandibular Incisor Re-Crowding: Is It Different in Extraction and Non-Extraction Cases?
52. (2023, June 06). Stability and Relapse after Orthodontic Treatment of Deep Bite Cases—A Long-Term Follow-Up Study—PubMed, Available online: https://pubmed.ncbi.nlm.nih.gov/23197574/.
53. Stability of Anterior Tooth Alignment 10 Years out of Retention10.1007/s00056-017-0084-2 ↗
54. Stability of Orthodontic Treatment Outcome in Relation to Retention Status: An 8-Year Follow-Up10.1016/j.ajodo.2016.10.032 ↗
55. Non-Hodgkin Lymphoma Affecting the Tongue: Unusual Intra-Oral Location10.1186/1758-3284-3-1 ↗
56. Vaida, L.L., Bud, E.S., Halitchi, L.G., Cavalu, S., Todor, B.I., Negrutiu, B.M., Moca, A.E., and Bodog, F.D. (2020). The Behavior of Two Types of Upper Removable Retainers—Our Clinical Experience. Children, 7.10.3390/children7120295 ↗
57. Reddy, L.K.V., Madithati, P., Narapureddy, B.R., Ravula, S.R., Vaddamanu, S.K., Alhamoudi, F.H., Minervini, G., and Chaturvedi, S. (2022). Perception about Health Applications (Apps) in Smartphones towards Telemedicine during COVID-19: A Cross-Sectional Study. J. Pers. Med., 12.10.3390/jpm12111920 ↗
58. Rathi, S., Chaturvedi, S., Abdullah, S., Rajput, G., Alqahtani, N.M., Chaturvedi, M., Gurumurthy, V., Saini, R., Bavabeedu, S.S., and Minervini, G. (2023). Clinical Trial to Assess Physiology and Activity of Masticatory Muscles of Complete Denture Wearer Following Vitamin D Intervention. Medicina, 59.10.3390/medicina59020410 ↗
59. Mummolo, S., Mancini, L., Quinzi, V., D’Aquino, R., Marzo, G., and Marchetti, E. (2020). Rigenera® Autologous Micrografts in Oral Regeneration: Clinical, Histological, and Radiographical Evaluations. Appl. Sci., 10.10.3390/app10155084 ↗