journal article·2023-08-06Open access

Comparison of Orbital Reconstructive Effect between Customized Orbital Implants Using Three-Dimensional Printed Templates and Conventional Manual-Bending Implants in Blowout Fracture Surgery

Min-Seo Kwon, Hyun Shin

Applied Sciences· Volume 13· Issue 15

Abstract

The aim of the present study was to determine the orbital reconstructive effect of customized orbital implants using three-dimensional (3D) printed templates compared with conventional manual-bending implants using computed tomography (CT)-based orbital volume measurements. This retrospective study reviewed the medical records and 3D-CT images of 90 patients who underwent medial, inferior, or inferomedial orbital wall reconstruction. The selected patients were categorized into two groups: (1) the 3D group that underwent surgery using 3D-printed customized orbital implant templates and (2) the manual group that received a conventional manual technique to mold the implant. The volume discrepancy (VD) was obtained by subtracting the volume of the contralateral unaffected eye from that of the injured eye. Of the 90 patients, 33 and 57 were divided into the 3D and manual groups, respectively. The volumes on the contralateral unaffected side and on the pre- and postoperative injured sides were 22.5 ± 2.9, 23.7 ± 3.0, and 22.3 ± 2.8 cm3 (mean ± SD), respectively, in the 3D group, and 21.5 ± 2.5, 22.7 ± 2.8, and 21.2 ± 2.7 cm3 in the manual group. The postoperative VD did not differ between the 3D (–0.2 ± 0.3 cm3) and manual (–0.3 ± 0.9 cm3) groups (p = 0.794). The volume on the postoperative injured side did not differ significantly from that on the contralateral unaffected side in the 3D group, but these did differ significantly in the manual group. Postoperative VD also increased with the preoperative VD in the manual group (Pearson correlation coefficient = 0.548, p = 0.001), whereas there was no such association in the 3D group. The orbital volume restoration effect had superior surgical outcomes for large fractures using the customized orbital implant with 3D-printed templates compared with manual-bending implants.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Facial Trauma and Fracture Management · Traumatic Ocular and Foreign Body Injuries · Craniofacial Disorders and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Medicine, Konkuk University, Seoul 50529, Republic of Korea

Department of Ophthalmology, Research Institute of Medical Sciece, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul 50529, Republic of Korea

Funding

National Research Foundation of Korea (NRF)

References (28)

Show source-provided references
1. Endoscopic approach to orbital blowout fracture repair10.1016/j.otohns.2004.05.017 ↗
2. Anatomical 3-dimensional pre-bent titanium implant for orbital floor fractures10.1016/j.ophtha.2006.03.062 ↗
3. Orbital fractures: A review10.2147/OPTH.S14972 ↗
4. An analysis of pure blowout fractures and associated ocular symptoms10.1097/SCS.0b013e31829026ca ↗
5. Computer-assisted secondary reconstruction of unilateral posttraumatic orbital deformity
6. Basic research and 12 years of clinical experience in computer-assisted navigation technology: A review10.1016/j.ijom.2004.03.018 ↗
7. Challenges and Possibilities of Cell-Based Tissue-Engineered Vascular Grafts10.34133/2021/1532103 ↗
8. Yi, H., Kim, S., Kim, M., Kim, J., Jeon, J.S., and Park, J. (2023). Bioprinting methods for fabricating in vitro tubular blood vessel models. Cyborg Bionic Syst., in press.
9. 3D Bioprinted Spheroidal Droplets for Engineering the Heterocellular Coupling between Cardiomyocytes and Cardiac Fibroblasts10.34133/2021/9864212 ↗
10. The accuracy of patient specific implant prebented with 3D-printed rapid prototype model for orbital wall reconstruction10.1016/j.jcms.2017.03.010 ↗
11. Generation of customized orbital implant templates using 3-dimensional printing for orbital wall reconstruction10.1038/s41433-018-0193-1 ↗
12. A novel method of orbital floor reconstruction using virtual planning, 3-dimensional printing, and autologous bone10.1016/j.joms.2016.03.044 ↗
13. Clinical effects of 3-D printing-assisted personalized reconstructive surgery for blowout orbital fractures10.1007/s00417-017-3766-y ↗
14. Rapid prototyped patient specific implants for reconstruction of orbital wall defects10.1016/j.jcms.2014.05.006 ↗
15. Relationship between the extent of fracture and the degree of enophthalmos in isolated blowout fractures of the medial orbital wall10.1016/S0278-2391(00)90152-6 ↗
16. Evaluation of computer-based area and volume measurement from coronal computed tomography scans in isolated fractures of the orbital floor10.1053/joms.2002.35722 ↗
17. Correlation between volume of herniated orbital contents and the amount of enophthalmos in orbital floor and wall fractures10.1016/j.joms.2011.02.036 ↗
18. Customized Titanium Mesh Based on the 3D Printed Model vs. Manual Intraoperative Bending of Titanium Mesh for Reconstructing of Orbital Bone Fracture: A Randomized Clinical Trial
19. Kim, J.H., Lee, C.R., Oh, D.Y., Jun, Y.J., and Moon, S.H. (2021). Comparison of Efficacy between Three-Dimensional Printing and Manual-Bending Implants for Inferomedial Orbital Fracture: A Retrospective Study. Appl. Sci., 11.10.3390/app11177971 ↗
20. Use of 3D Printed Models to Create Molds for Shaping Implants for Surgical Repair of Orbital Fractures10.1016/j.acra.2019.06.023 ↗
21. The Role of 3D Printing in Planning Complex Medical Procedures and Training of Medical Professionals—Cross-Sectional Multispecialty Review10.3390/ijerph19063331 ↗
22. Lauren, S., Michelle, H., Fields, J.M., Backlund, E., Robert, P., and Kristy, M.S. (2022). Standardizing evaluation of patient-specific 3D printed models in surgical planning: Development of a cross-disciplinary survey tool for physician and trainee feedback. BMC Med. Educ., 22.10.1186/s12909-022-03581-7 ↗
23. Application of three-dimensional printing technology in orbital floor fracture reconstruction10.1016/j.tcr.2018.09.006 ↗
24. Orbital volume restoration rate after orbital fracture’ a CT-based orbital volume measurement for evaluation of orbital wall reconstructive effect10.1038/eye.2016.311 ↗
25. Age-and sex-related changes in the soft tissues of the orbital region
26. Threedimensional pre-bent titanium implant for concomitant orbital floor and medial wall fractures in an East asian population10.5999/aps.2014.41.5.480 ↗
27. Considerations for the Management of Medial Orbital Wall Blowout Fracture10.5999/aps.2016.43.3.229 ↗
28. Intraoperative Computed Tomography Scan for Orbital Fracture Reconstruction10.1097/SCS.0000000000005667 ↗