Evaluation of the Retentive Forces from Removable Partial Denture Clasps Manufactured by the Digital Method
Source abstract
Abstract
The purpose of this study was to evaluate the retentive forces over time of removable partial denture clasps fabricated by the digital method. Occlusal rest seats were fabricated on three premolar teeth fixed in acrylic blocks (9 × 20 × 40 mm). Digitization of the teeth was performed using a laboratory scanner (Zirkonzahn Scanner S600 GmbH, Gais, Italy). After the analysis and determination of the insertion axis, two types of clasps with mesial occlusal rests were designed per tooth: the back-action and the reverse back-action clasps, using the Partial Planner Zirkonzahn program. The file was sent for fabrication of six metal clasps from a cobalt-chromium SP2 alloy in the EOSINT M270 system by a direct laser sintering process. The Instron 5544 universal testing machine was used to perform 20,000 cycles of clasp insertion and removal in the corresponding tooth with a load cell of 100 N and a speed of 2.5 mm/s. The retentive force was recorded for each of the 1000 cycles, and the change in retention over time was calculated. Statistical analysis was performed using the nonparametric Mann–Whitney test and a significance level of 5%. At 16,000 cycles, a maximum change in retention of 3.74 N was recorded for the back-action clasps and a minimum of −24.28 N at 1000 cycles for the reverse back-action clasps. The reverse back-action clasps exhibited statistically significant lower change in retention than the reverse-action clasps at 4000 and 5000 cycles. No differences were observed in the remaining cycles. During the 20,000 cycles, the change in retention was low regardless of the type of clasp. For most cycles, there were no differences in the change in retention between the two types of clasps.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Dental Research and COVID-19
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Instituto Superior de Engenharia de Lisboa, 1959-007 Lisboa, Portugal
Instituto Politécnico de Lisboa, 1549-020 Lisboa, Portugal
IDMEC, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisboa, Portugal
Biomedical and Oral Sciences Research Unit (UICOB), Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal
Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal
References (40)
Show source-provided references
1. The Fit Accuracy of Removable Partial Denture Metal Frameworks Using Conventional and 3D Printed Techniques: An in Vitro Study10.5005/jp-journals-10024-2542 ↗
2. Revisiting the Removable Partial Denture
3. Removable Partial Dentures: Use of Rapid Prototyping10.1111/jopr.12154 ↗
4. Internal Porosities, Retentive Force, and Survival of Cobalt-Chromium Alloy Clasps Fabricated by Selective Laser-Sintering10.1016/j.jpor.2019.07.006 ↗
5. Failures in the Rehabilitation Treatment with Removable Partial Dentures10.3109/00016357.2013.777780 ↗
6. Patient Satisfaction with Laser-Sintered Removable Partial Dentures: A Crossover Pilot Clinical Trial10.1016/j.prosdent.2017.04.021 ↗
7. A Critically Appraised Topic Review of Computer-Aided Design/Computer-Aided Machining of Removable Partial Denture Frameworks
8. Retentive Forces and Fatigue Resistance of Thermoplastic Resin Clasps10.1016/j.dental.2011.10.016 ↗
9. Removable Partial Denture Alloys Processed by Laser-Sintering Technique10.1002/jbm.b.33929 ↗
10. Removable Partial Dentures: The Clinical Need for Innovation10.1016/j.prosdent.2017.01.008 ↗
11. An Overview of Digital Intraoral Scanners: Past, Present and Future-from an Orthodontic Perspective
12. Relationship between the Standards of Removable Partial Denture Construction, Clinical Acceptability, and Patient Satisfaction10.1016/S0022-3913(00)70008-4 ↗
13. Removable Partial Dentures: Clinical Concepts
14. Accuracy of CAD-CAM-Fabricated Removable Partial Dentures10.1016/j.prosdent.2017.04.017 ↗
15. Effects of Long-Term Simulated RPD Clasp Attachment/Detachment on Retention Loss and Wear for Two Clasp Types and Three Abutment Material Surfaces
16. Effects of Repetitive Insertion/Removal Cycles and Simulated Occlusal Loads on Retention of Denture Retainers10.4012/dmj.2020-462 ↗
17. Effect of Different Materials and Undercut on the Removal Force and Stress Distribution in Circumferential Clasps during Direct Retainer Action in Removable Partial Dentures10.1016/j.dental.2019.11.022 ↗
18. Effect of Cyclic Bend Loading on a Cobalt-Chromium Clasp Fabricated by Direct Metal Laser Sintering10.1016/j.prosdent.2018.03.016 ↗
19. New Clasp Assembly for Distal Extension Removable Partial Dentures: The Reverse RPA Clasp10.1111/jopr.12313 ↗
20. RPA Clasp Design for Distal-Extension Removable Partial Dentures10.1016/0022-3913(83)90232-9 ↗
21. Cyclic Fatigue Properties of Cobalt-Chromium Alloy Clasps for Partial Removable Dental Prostheses10.1016/S0022-3913(10)60173-4 ↗
22. A Comparative Analysis of the Corrosive Effect of Artificial Saliva of Variable PH on DMLS and Cast Co-Cr-Mo Dental Alloy10.3390/ma7096486 ↗
23. Dikova, T. (2018). Properties of Co-Cr Dental Alloys Fabricated Using Additive Technologies, InTech. Biomaterials in Regenerative Medicine.10.5772/intechopen.69718 ↗
24. Selective Laser Melting Technique in Fabrication of Partial Denture Metal Framework
25. Conceição, P., Portugal, J., Franco, M., Alves, N.M., Marques, D., and Neves, C.B. (2023). Comparison between Digital Superimposition and Microcomputed Tomography Methods of Fit Assessment of Removable Partial Denture Frameworks. J. Prosthet. Dent., 6.10.1016/j.prosdent.2023.02.002 ↗
26. Fit Accuracy of Metal Partial Removable Dental Prosthesis Frameworks Fabricated by Traditional or Light Curing Modeling Material Technique: An in Vitro Study10.1016/j.sdentj.2014.11.013 ↗
27. da F.P. Accuracy of CAD-CAM Systems for Removable Partial Denture Framework Fabrication: A Systematic Review10.1016/j.prosdent.2020.01.003 ↗
28. Advancements in CAD/CAM Technology: Options for Practical Implementation10.1016/j.jpor.2016.01.003 ↗
29. A Review of Computer-Aided Design/Computer-Aided Manufacture Techniques for Removable Denture Fabrication10.4103/1305-7456.178304 ↗
30. Trends in Computer-Aided Manufacturing in Prosthodontics: A Review of the Available Streams10.1155/2014/783948 ↗
31. Belinha, J., Campos, J.C.R., Fonseca, E., Silva, M.H.F., Marques, M.A., Costa, M.F.G., and Oliveira, S. (2022). Advances and Current Trends in Biomechanics, CRC Press.10.1201/9781003217152 ↗
32. Direct Metal Laser Sintering: A Digitised Metal Casting Technology10.1007/s13191-013-0256-8 ↗
33. Additive Manufacturing Technologies Used for 3D Metal Printing in Dentistry10.1007/s40496-017-0152-0 ↗
34. Fitness and Retentive Force of Cobalt-Chromium Alloy Clasps Fabricated with Repeated Laser Sintering and Milling10.1016/j.jpor.2018.01.001 ↗
35. Fit Accuracy of Removable Partial Denture Metal Frameworks Produced by CAD-CAM–a Clinical Study
36. A Study of Enamel Abrasion as Related to Partial Denture Clasps10.1016/0022-3913(56)90011-7 ↗
37. Comparative Study of Circumferential Clasp Retention Force for Titanium and Cobalt-Chromium Removable Partial Dentures10.1067/mpr.2002.128128 ↗
38. Change in the Retentive Force of Akers Clasp for Zirconia Crown by Repetitive Insertion and Removal Test10.1016/j.jpor.2019.02.005 ↗
39. Finite Element Analysis on Preferable I-Bar Clasp Shape10.1046/j.1365-2842.2001.00673.x ↗
40. Kim, H.R., Jang, S.H., Kim, Y.K., Son, J.S., Min, B.K., Kim, K.H., and Kwon, T.Y. (2016). Microstructures and Mechanical Properties of Co-Cr Dental Alloys Fabricated by Three CAD/CAM-Based Processing Techniques. Materials, 9.10.3390/ma9070596 ↗